The AirTAC GAC F.R.L. Unit GAC300C08ALNK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/4" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for downstream pneumatics, the GAC300C08ALNK pre-assembles a filter, regulator and lubricator on a single L-shape bracket with quick mounting clamps. This 1/4in ported unit features a robust metal bowl and a 40 um element, operating within the lower 0.15-0.4 MPa (20-58 psi) pressure band. Because the lubricator sits last in the sequence, oil mist is introduced downstream of the regulator seat to prevent fouling.
Weighing 1300 g, the assembly incorporates an automatic drain that clears condensate from the 60 cc bowl without operator intervention, making it well suited for unattended or wet lines. A reverse-flow (reflux) valve is fitted, which the catalogue depicts as a separate pneumatic symbol with details on its own page. No gauge is supplied, but a 1/8in connection is provided if you need to add instrumentation to monitor the set pressure.
| Model | Airtac GAC F.R.L. Unit GAC300C08ALNK |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 1/4" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC300 is 1/8" if you add one.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 08 | Port size 1/4". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF300-08 filter, GAR300-08 regulator, GAL300-08 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 1/4" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds delicate pneumatic clamps on electronics assembly lines where actuator force must stay below 0.4 MPa to avoid crushing components.
Conditions air for low-pressure bagging and sealing machines, adding the required oil mist for moving jaws without over-pressurizing the film.
Supplies regulated, lubricated air to laboratory distribution panels where a 1/4in port and a 1300 g footprint fit tight bench frames.
Choose this lower-pressure type when your machine strictly operates within 0.15-0.4 MPa (20-58 psi); if the application may ever demand more, select the standard type instead. The metal bowl offers a durable housing option for harsher environments, while the 40 um element balances standard particle capture with longer service intervals compared to the finer 5 um option. Should a component fail, you can order spares individually using the shared body-port suffix: GAF300-08, GAR300-08 and GAL300-08. Stepping up to the GAC400 roughly doubles the flow envelope to 6000 L/min at 0.7 MPa inlet, but the L-type ceiling restricts you to 44% of the standard 0.9 MPa maximum.
AirtacDistr lists every GAC300-08 order code with its price on one page at https://airtacdistr.com/products/airtac-gac300-08-three-unit-frl
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This lower-pressure unit regulates from 0.15-0.4 MPa (20-58 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C, weighs 1300 g, has a 60 cc drain bowl and a 98 cc oil bowl, and uses ISO VG 32 lubricant.
The N in the ordering code indicates no gauge is supplied, so the set pressure cannot be read directly unless you add one later via the 1/8in gauge connection. The PT thread default means any added gauge should read in MPa/psi.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.