The AirTAC GAC F.R.L. Unit GAC300C08SNWTK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/4" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for pneumatic systems, this AirTAC GAC300C08SNWTK is a complete F.R.L. combination rather than a single device. The assembly pairs a filter, regulator and lubricator on a shared L-shape bracket, pre-plumbed so there is no inter-unit tubing to leak. Air passes through the 5 um element before the pressure is set, and oil mist is introduced downstream of the regulator seat to prevent fouling. Built with a 1/4in port, the unit operates at 0.15-0.9 MPa (20-130 psi).
The metal bowl equips this specific unit for rugged environments where standard PC plastic might not be suitable, while the 60 cc condensate sump and 98 cc oil reservoir dictate the maintenance rhythm. A semi-auto and manual drain combination is fitted to clear water. No pressure gauge is supplied, but the body features a 1/8in gauge connection for adding one later. The reverse-flow (reflux) valve is fitted, shown as a separate pneumatic symbol in the catalogue. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC300C08SNWTK |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 1/4" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Metal |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC300 is 1/8" if you add one.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 08 | Port size 1/4". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF300-08 filter, GAR300-08 regulator, GAL300-08 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 1/4" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds clean, oil-misted air to precision tool changers where the 5 um element protects sensitive pneumatic grippers from fine particulate ingress.
Conditions air for automated form-fill-seal packaging lines, ensuring the regulator holds steady pressure for consistent film feeding and cutting cylinders.
Supplies lubricated air to the pneumatic valves of a press brake, with the metal bowl providing durability in a heavy-duty metal fabrication shop.
Choose this GAC300 body for mid-scale duties; stepping up to the GAC400 brings a larger 100 cc condensate bowl but adds weight, whereas this 1300 g unit balances capacity and panel space. The 5 um element here traps far finer particles than the standard 40 um grade, suiting precision valves at the cost of more frequent element swaps. If the downstream line must remain oil-free, omit the lubricator and select a filter-regulator instead. Spares follow the body-port suffix exactly: GAF300-08, GAR300-08 and GAL300-08. The catalogue flow curve for the GAC300 is plotted to 3000 L/min at 0.7 MPa inlet, which is roughly 50% of the GAC400's 6000 L/min envelope. Because the maximum supply is 1.0 MPa and the Standard type regulates to 0.9 MPa, there is only about 0.1 MPa of headroom above the top setting.
AirtacDistr lists every GAC300-08 order code with its price on one page at https://airtacdistr.com/products/airtac-gac300-08-three-unit-frl
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This standard type unit regulates from 0.15-0.9 MPa (20-130 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It operates in temperatures from -5 to 70 C, weighs 1300 g, and features a 60 cc drain bowl alongside a 98 cc oil bowl. The recommended lubricant is ISO VG 32.
The N in the ordering code indicates no gauge is supplied. The body retains a 1/8in gauge connection, allowing operators to install a separate gauge reading MPa/psi for the default NPT thread. Without adding one, the set outlet pressure cannot be visually read.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.