AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC300-10 FRL Unit (GC30010MC1T)

The AirTAC GC300-10 FRL Unit (GC30010MC1T) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/8" ports, a 40 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT3/8"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$107.41 $114.91Save 6% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC300-10 drain, gauge and thread option on one page All GC300-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC300-10 FRL Unit (GC30010MC1T)

The AirTAC GC series is a three-unit F.R.L.: a separate air filter, pressure regulator and lubricator that together remove water and particulate, hold a set downstream pressure and add oil-mist lubrication to compressed air. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Bowls at size 300 are polycarbonate; maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing).

This is a genuine AirTAC part. The G series is available in sizes 200, 300, 400 and 600 with ports from 1/8 to 1 inch, plus automatic or differential-pressure drains, a 5 um element (W), other gauge scales, G or NPT threads and an optional bracket. AirTAC publishes flow for the G series as curves rather than one rated figure, so we confirm flow and datasheet details for your application on request. Order code GC30010MC1T has NPT ports (the T in the code) for North American pipe fittings.

AirTAC GC300-10 FRL Unit (GC30010MC1T) Technical Specifications

ModelAirTAC GC300-10 FRL Unit (GC30010MC1T)
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT3/8" (NPT thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC300-10 FRL Unit (GC30010MC1T)

GC300G-series F.R.L. combination, 300 body — sets the port range.
10Port size PT3/8". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-10 filter, GR300-10 regulator and GL300-10 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT3/8" · 40 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-10
Build orderFilter → regulator → lubricator

Where the AirTAC GC300-10 FRL Unit (GC30010MC1T) Is Used

handyman

Workshop bench air drops

A drop-fed F.R.L. at a maintenance bench supplying impact wrenches, air ratchets and blow guns, with the operator draining the bowl during daily checks and reading the setting off the MPa gauge.

conveyor_belt

Bottling conveyor pushers

Conditioning the air that drives bottle pushers and stopper cylinders along a bottling hall conveyor, where the line crew walks past and can drain the bowl on schedule.

settings_input_component

Machine panel actuator banks

Feeding a bank of solenoid valves and small cylinders inside a machine cabinet, with the round MPa gauge giving the setter a clear pressure reference at the panel.

Is the AirTAC GC300-10 FRL Unit (GC30010MC1T) the Right Station?

Size 300 with NPT3/8 ports is the mid-range step in the G series; step to 400 or 600 for heavier demand or 200 for light circuits, matching the size to the demand rather than the pipe alone. This build has the manual drain (M): condensed water is released by hand as part of routine checks, which suits attended posts; choose automatic (A) or differential-pressure drainage where the bowl cannot be watched. With a manual drain the regulator adjusts 0.05-0.9 MPa (7-130 psi), and the C1 code adds the external round gauge with MPa scale.

This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. AirTAC gives flow as curves, not a single rated figure, so ask us to confirm sizing against your application before ordering.

AirtacDistr lists every GC300-10 order code with its price on one page at https://airtacdistr.com/products/airtac-gc300-10-three-unit-frl

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-10 regulator with a GF300-10 filter on that branch.

AirTAC GC300-10 FRL Unit (GC30010MC1T) FAQ

AirTAC publishes G-series flow as selection curves rather than a single rated figure, so no honest l/min or SCFM number can be quoted here. Send us your line pressure and air demand and we will confirm the size 300 fit - or whether 200, 400 or 600 suits better - straight from the datasheet before you order.

The M in GC30010MC1T is the manual drain: the bowl is drained by hand during routine checks, which suits attended posts such as workshop drops. Automatic (A) drains the bowl on its own, and differential-pressure drainage is the catalogue default; note that with a manual drain the regulator adjusts 0.05-0.9 MPa (7-130 psi), versus 0.15-0.9 MPa (20-130 psi) on automatic or differential builds. We can confirm the right drain for your duty before you order.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC300-10 FRL Unit (GC30010MC1T)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.