AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC300-15 FRL Unit (GC30015MC3T)

The AirTAC GC300-15 FRL Unit (GC30015MC3T) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 40 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$107.41 $114.91Save 6% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC300-15 drain, gauge and thread option on one page All GC300-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC300-15 FRL Unit (GC30015MC3T)

The GC30015MC3T is an AirTAC G-series three-unit F.R.L. combination: a separate air filter, pressure regulator and lubricator assembled as one set. This configuration gives you full air treatment in one pass - water and 40 um particulate removed by the filter, outlet pressure held steady by the regulator (0.05-0.9 MPa / 7-130 psi with manual drain), and oil mist added by the lubricator for downstream air tools and cylinders. The manual-drain bowls on the 300 size are PC (polycarbonate), and the code specifies an external round gauge with a bar scale on the 1/2 in NPT threaded ports.

This is a genuine AirTAC part. The GC series is also available in 200, 300, 400 and 600 sizes with 1/8 in through 1 in ports, G (BSPP) or NPT thread options, automatic or differential-pressure drains, a 5 um filter element (suffix W) and MPa, psi or bar gauge scales. Rated flow figures are published only as curves, so we confirm the datasheet and sizing for your application on request.

AirTAC GC300-15 FRL Unit (GC30015MC3T) Technical Specifications

ModelAirTAC GC300-15 FRL Unit (GC30015MC3T)
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (NPT thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — round, bar scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC300-15 FRL Unit (GC30015MC3T)

GC300G-series F.R.L. combination, 300 body — sets the port range.
15Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
3Gauge scale: bar. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-15 filter, GR300-15 regulator and GL300-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT1/2" · 40 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-15
Build orderFilter → regulator → lubricator

Where the AirTAC GC300-15 FRL Unit (GC30015MC3T) Is Used

precision_manufacturing

CNC machining centre air supply

Feeds filtered, regulated and lubricated air to the tool-changer, clamps and air-powered fixtures on a machining cell, protecting spindles of actuators downstream from water and scale in shop air.

view_module

Packaging line actuation

Conditions the air feeding carton sealers, case erectors and pick-and-place cylinders on a packaging line, where stable regulated pressure keeps stroke timing consistent across the shift.

air

Pneumatic tool stations

Mounted at a maintenance-drop or assembly bench, the set filters particulate, holds set pressure and meters oil mist into impact wrenches, riveters and air ratchets to extend tool life.

Is the AirTAC GC300-15 FRL Unit (GC30015MC3T) the Right Station?

Step up or down by size: 200, 300, 400 and 600 bring progressively larger ports and flow capacity, so pick the step that matches your line demand - here that is size 300 with a 1/2 in NPT port. Choose the drain to suit access: manual drain (as coded here) needs someone to open the bowl, while automatic or differential-pressure drains suit unattended installations; note the regulator range differs by drain type (0.05-0.9 MPa with manual, 0.15-0.9 MPa with auto/differential). Stay with the standard 40 um element for general plant air or order the W suffix for 5 um. Gauge is round with a bar scale in this code; This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.

Because flow is published as curves rather than a single rating, ask us to confirm sizing against your application before ordering.

AirtacDistr lists every GC300-15 order code with its price on one page at https://airtacdistr.com/products/airtac-gc300-15-three-unit-frl

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-15 regulator with a GF300-15 filter on that branch.

AirTAC GC300-15 FRL Unit (GC30015MC3T) FAQ

AirTAC publishes flow for the GC series as performance curves, not a single rated number, so there is no one figure we can honestly quote. Tell us your inlet pressure and required flow and we will confirm the correct size and datasheet figures for the GC30015MC3T on request before you order.

The M code means the condensate bowls are drained by hand, which suits attended installations where an operator drains bowls during routine checks. It also gives the widest regulator setting range (0.05-0.9 MPa / 7-130 psi versus 0.15-0.9 MPa with automatic or differential-pressure drains). For unattended or hard-to-reach installations, specify the automatic-drain version instead.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC300-15 FRL Unit (GC30015MC3T)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.