verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC400-10 FRL Unit (GC40010LC1T)

The AirTAC GC400-10 FRL Unit (GC40010LC1T) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/8" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$155.22 $162.72Save 4% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC400-10 drain, gauge and thread option on one page All GC400-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC400-10 FRL Unit (GC40010LC1T)

GC40010LC1T is an AirTAC GC-series three-unit F.R.L. combination in the low-pressure L type, sized for a 3/8in NPT port. It pairs the standard 40um filter element with a low-pressure regulator and an oil-mist lubricator, and the external round gauge reads in MPa. Because this is the L type, the regulator's adjustment span differs from the standard set, so ask us to confirm the exact range against your supply pressure before ordering.

This is a genuine AirTAC part in size 400 of the GC range (200/300/400/600). Maximum inlet pressure is 1.0 MPa (145 psi), the working temperature range is -5 to 70 C non-freezing, and the filter and lubricator bowls are polycarbonate at this size. AirTAC publishes flow as curves rather than a single rated figure, so ask us for the datasheet and we will confirm the figures for your application.

AirTAC GC400-10 FRL Unit (GC40010LC1T) Technical Specifications

ModelAirTAC GC400-10 FRL Unit (GC40010LC1T)
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT3/8" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC400-10 FRL Unit (GC40010LC1T)

GC400G-series F.R.L. combination, 400 body — sets the port range.
10Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-10 filter, GR400-10 regulator and GL400-10 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · PT3/8" · 40 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-10
Build orderFilter → regulator → lubricator

Where the AirTAC GC400-10 FRL Unit (GC40010LC1T) Is Used

science

Test rig low-pressure air

Supplies low-pressure air to a laboratory or QA test rig where the regulator is set well below standard line pressure and the round gauge gives a direct MPa reading.

view_module

Glass handling air table

Floats and conveys glass or sheet panels on an air table that runs at low regulated pressure off the shop main.

tune

Fixture clamping at low pressure

Holds workpieces on a machining fixture whose clamping circuit is designed to run at a low regulated setting rather than full line pressure.

Is the AirTAC GC400-10 FRL Unit (GC40010LC1T) the Right Station?

Pick the L type when the process downstream is designed to run at low regulated pressure rather than the standard band; the standard GC40010 sets with the differential-pressure drain regulate across 0.15-0.9 MPa (20-130 psi), and we will confirm the L-type adjustment range on request. This code uses the 40um standard element (choose W for 5um) and an external round MPa gauge - the embedded square gauge is the F-code alternative, with psi or bar scales orderable. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. AirTAC publishes flow only as curves, so ask us to verify this model against your air demand before ordering.

AirtacDistr lists every GC400-10 order code with its price on one page at https://airtacdistr.com/products/airtac-gc400-10-three-unit-frl

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-10 regulator with a GF400-10 filter on that branch.

AirTAC GC400-10 FRL Unit (GC40010LC1T) FAQ

AirTAC does not publish a single rated flow number for this unit; flow appears only as curves that depend on supply pressure and the regulator setting. Send us your conditions and demand and we will confirm the sizing from the datasheet on request.

The C in this code selects the external round gauge with a MPa scale, while F-code sets such as the GC40010F1 use the embedded square gauge. Both read pressure on units with a regulator, and scale variants (1 MPa, 2 psi, 3 bar) are available to order. The other difference in this code is the L low-pressure regulator type.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC400-10 FRL Unit (GC40010LC1T)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.