verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC600 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC600-20 FRL Unit (GC60020F1WT)

The AirTAC GC600-20 FRL Unit (GC60020F1WT) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/4" ports, a 5 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT3/4"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainDifferential-pressure drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadNPT
$238.79 $246.29Save 3% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC600-20 drain, gauge and thread option on one page All GC600-20 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC600-20 FRL Unit (GC60020F1WT)

The AirTAC GC series is a three-unit F.R.L. combination: separate filter, regulator and lubricator units conditioning compressed air in one line. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. It carries an embedded square pressure gauge scaled in MPa, and with the differential-pressure drain the regulator adjusts from 0.15 to 0.9 MPa (20 to 130 psi). Maximum working pressure is 1.0 MPa (145 psi), operating temperature is -5 to 70 C (non-freezing), the medium is compressed air only, and at the 600 size the filter bowl is aluminium alloy.

This is a genuine AirTAC part. The G series spans sizes 200, 300, 400 and 600 with a choice of ports, drains, filter grades, gauges and threads, so the set can be matched to most plant air mains. Flow for the series is published as performance curves rather than a single rated figure; we confirm the datasheet and flow data for this model on request. Order code GC60020F1WT has NPT ports (the T in the code) for North American pipe fittings.

AirTAC GC600-20 FRL Unit (GC60020F1WT) Technical Specifications

ModelAirTAC GC600-20 FRL Unit (GC60020F1WT)
SeriesGC600 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT3/4" (NPT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialAluminium alloy
Pressure gaugeFitted — square, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC600-20 FRL Unit (GC60020F1WT)

GC600G-series F.R.L. combination, 600 body — sets the port range.
20Port size PT3/4". This body offers 20 = PT3/4", 25 = PT1".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-20 filter, GR600-20 regulator and GL600-20 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC600 · PT3/4" · 5 µm
One size downGC400
Two-unit equivalentGFC600-20
Build orderFilter → regulator → lubricator

Where the AirTAC GC600-20 FRL Unit (GC60020F1WT) Is Used

science

Laboratory test rig actuation

Supplies regulated, oil-misted air to the cylinders and directional valves on a materials test rig, where the 5 um element is selected because the standard 40 um grade is too coarse for the rig's finer pneumatic components.

precision_manufacturing

Electronics assembly cell

Conditions air for pick-and-place cylinders and actuated valves on an electronics assembly cell; the W grade is specified where the standard 40 um element does not give the cleanliness the cell's valves need.

build

Automotive weld cell clamps

Feeds the pneumatic clamp cylinders on a robotic weld cell fixture, combining regulation at the cell with fine 5 um filtration ahead of the directional valves that sequence the clamps.

Is the AirTAC GC600-20 FRL Unit (GC60020F1WT) the Right Station?

The decodable choices: this is a 600 with a 3/4 in NPT connection - the largest size step in the G series - so pick the size against the flow your main consumes. Drain is the standard differential-pressure type on this code; automatic and manual drain versions are separate models. Filter grade is the 5 um W element here; choose a code without W if the standard 40 um grade is sufficient, since the finer element is a real selection decision, not a free upgrade. Gauge is the square type scaled in MPa; round bar-scale and no-gauge options are separate codes. Thread is three thread types (NPT on this code).

Flow is published as curves rather than one rated number, so ask us to confirm sizing against the datasheet for your application before ordering.

AirtacDistr lists every GC600-20 order code with its price on one page at https://airtacdistr.com/products/airtac-gc600-20-three-unit-frl

Quick checklist

  • ✓ Body size for your peak flow (PT3/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-20 regulator with a GF600-20 filter on that branch.

AirTAC GC600-20 FRL Unit (GC60020F1WT) FAQ

AirTAC publishes G-series flow as performance curves rather than a single rated figure, so no flow number is quoted here. Request the datasheet from us and we will confirm the flow data for the 600 / 3/4 in set against your application before you order.

The standard 40 um grade suits general actuation circuits; the W grade filters down to 5 um and is the right choice when downstream valves or cylinders are sensitive to finer particles. On this model the W grade is combined with the MPa square gauge; other grade and gauge combinations exist as separate codes.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC600-20 FRL Unit (GC60020F1WT)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.