The AirTAC GC600-20 FRL Unit (GC60020NTK) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/4" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
GC60020NTK is a genuine AirTAC G-series three-unit F.R.L. combination - separate filter, regulator and lubricator - that cleans, regulates and oil-mist lubricates compressed air. The K suffix means a reverse/check valve is fitted, which holds downstream pressure if the upstream supply is interrupted. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. the standard-type regulator adjusts from 0.15-0.9 MPa (20-130 psi) and no gauge is fitted. Maximum working pressure is 1.0 MPa (145 psi), temperature range -5 to 70 C (non-freezing), and at size 600 the bowls are aluminium alloy.
This is a genuine AirTAC part. The G-series runs from sizes 200 to 600 with ports from 1/8 in to 1 in, with options for automatic or manual drains, a 5 um filter grade (W), embedded square or external round gauges in MPa, psi or bar scale, and G (BSPP) or NPT threads. Flow for the series is published only as performance curves, not a single rated figure, so we confirm sizing and datasheet figures on request.
| Model | AirTAC GC600-20 FRL Unit (GC60020NTK) |
|---|---|
| Series | GC600 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT3/4" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | Aluminium alloy |
| Pressure gauge | Not fitted |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC600 | G-series F.R.L. combination, 600 body — sets the port range. |
|---|---|
| 20 | Port size PT3/4". This body offers 20 = PT3/4", 25 = PT1". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| N | No pressure gauge (N). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-20 filter, GR600-20 regulator and GL600-20 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC600 · PT3/4" · 40 µm |
|---|---|
| One size down | GC400 |
| Two-unit equivalent | GFC600-20 |
| Build order | Filter → regulator → lubricator |
Conditioning air to the grippers and clamps on a robotic welding cell, with the fitted check valve holding the regulated downstream pressure if the plant supply dips mid-cycle.
Supplying filtered, regulated and lubricated air to pneumatic nutrunners and impact tools at assembly stations, protecting the tools and keeping torque-consistent air at each drop.
Feeding prepared air to the many small cylinders and jets on weaving and knitting machines, where a maintained downstream pressure and oil mist keep production running between shifts.
Choose this code over the plain GC60020N when you want the fitted reverse/check valve to prevent backflow and hold the regulated downstream pressure during a supply dip. The 3/4 in NPT port suits larger plant air drops; step to GC60025 for a 1 in port or down to size 300/400 bodies for smaller circuits. The differential-pressure drain needs no operator action beyond normal checks; automatic and manual drain codes exist if your duty demands them. The standard 40 um element covers general plant air - use the W suffix codes for 5 um filtration. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Since flow is published as curves rather than a single rating, ask us to confirm sizing against your application before ordering.
AirtacDistr lists every GC600-20 order code with its price on one page at https://airtacdistr.com/products/airtac-gc600-20-three-unit-frl
Quick checklist
The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-20 regulator with a GF600-20 filter on that branch.
No - AirTAC publishes G-series flow as performance curves across a pressure range, not as one rated number. Share your operating pressure and air demand and we will read the flow for this unit off the datasheet and confirm it on request.
The K suffix means a reverse/check valve is fitted, so air will not flow back through the unit and downstream pressure is held if the upstream supply fails. The base GC60020N code is identical in size, port, filter grade and drain but without the check valve.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.