The AirTAC GC600-20 FRL Unit (GC60020NTK) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/4" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT3/4"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialAluminium alloy
  • Pressure gaugeNot fitted
  • ThreadNPT
$246.33 $253.83Save 2% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC600-20 drain, gauge and thread option on one page All GC600-20 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC600-20 FRL Unit (GC60020NTK)

GC60020NTK is a genuine AirTAC G-series three-unit F.R.L. combination - separate filter, regulator and lubricator - that cleans, regulates and oil-mist lubricates compressed air. The K suffix means a reverse/check valve is fitted, which holds downstream pressure if the upstream supply is interrupted. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. the standard-type regulator adjusts from 0.15-0.9 MPa (20-130 psi) and no gauge is fitted. Maximum working pressure is 1.0 MPa (145 psi), temperature range -5 to 70 C (non-freezing), and at size 600 the bowls are aluminium alloy.

This is a genuine AirTAC part. The G-series runs from sizes 200 to 600 with ports from 1/8 in to 1 in, with options for automatic or manual drains, a 5 um filter grade (W), embedded square or external round gauges in MPa, psi or bar scale, and G (BSPP) or NPT threads. Flow for the series is published only as performance curves, not a single rated figure, so we confirm sizing and datasheet figures on request.

AirTAC GC600-20 FRL Unit (GC60020NTK) Technical Specifications

ModelAirTAC GC600-20 FRL Unit (GC60020NTK)
SeriesGC600 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT3/4" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialAluminium alloy
Pressure gaugeNot fitted
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC600-20 FRL Unit (GC60020NTK)

GC600G-series F.R.L. combination, 600 body — sets the port range.
20Port size PT3/4". This body offers 20 = PT3/4", 25 = PT1".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-20 filter, GR600-20 regulator and GL600-20 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC600 · PT3/4" · 40 µm
One size downGC400
Two-unit equivalentGFC600-20
Build orderFilter → regulator → lubricator

Where the AirTAC GC600-20 FRL Unit (GC60020NTK) Is Used

settings_input_component

Robotic weld cell gripper circuits

Conditioning air to the grippers and clamps on a robotic welding cell, with the fitted check valve holding the regulated downstream pressure if the plant supply dips mid-cycle.

build

Assembly line air-tool drops

Supplying filtered, regulated and lubricated air to pneumatic nutrunners and impact tools at assembly stations, protecting the tools and keeping torque-consistent air at each drop.

view_module

Textile machine actuator banks

Feeding prepared air to the many small cylinders and jets on weaving and knitting machines, where a maintained downstream pressure and oil mist keep production running between shifts.

Is the AirTAC GC600-20 FRL Unit (GC60020NTK) the Right Station?

Choose this code over the plain GC60020N when you want the fitted reverse/check valve to prevent backflow and hold the regulated downstream pressure during a supply dip. The 3/4 in NPT port suits larger plant air drops; step to GC60025 for a 1 in port or down to size 300/400 bodies for smaller circuits. The differential-pressure drain needs no operator action beyond normal checks; automatic and manual drain codes exist if your duty demands them. The standard 40 um element covers general plant air - use the W suffix codes for 5 um filtration. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Since flow is published as curves rather than a single rating, ask us to confirm sizing against your application before ordering.

AirtacDistr lists every GC600-20 order code with its price on one page at https://airtacdistr.com/products/airtac-gc600-20-three-unit-frl

Quick checklist

  • ✓ Body size for your peak flow (PT3/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-20 regulator with a GF600-20 filter on that branch.

AirTAC GC600-20 FRL Unit (GC60020NTK) FAQ

No - AirTAC publishes G-series flow as performance curves across a pressure range, not as one rated number. Share your operating pressure and air demand and we will read the flow for this unit off the datasheet and confirm it on request.

The K suffix means a reverse/check valve is fitted, so air will not flow back through the unit and downstream pressure is held if the upstream supply fails. The base GC60020N code is identical in size, port, filter grade and drain but without the check valve.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC600-20 FRL Unit (GC60020NTK)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.