The AirTAC GC60020MLC2WTK F.R.L. Combination, NPT3/4 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/4" ports, a 5 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).
The AirTAC GC series is a three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator supplied as one matched set. This configuration is size 600 with NPT3/4 ports, fitted with a 5 um filter element (the W grade, finer than the 40 um standard), a manual drain on the filter bowl, a low-pressure type regulator, an external round gauge reading in psi, and a reverse/check valve. At size 600 the bowls are aluminium alloy. A mounting bracket is included.
This is a genuine AirTAC part. The GC series is available in sizes 200, 300, 400 and 600, with a choice of drain type, filter grade, gauge style and scale, and three thread types (NPT on this code). Maximum working pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing). Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet figures for your application. Order code GC60020MLC2WTK has NPT ports (the T in the code) for North American pipe fittings.
| Model | AirTAC GC60020MLC2WTK F.R.L. Combination, NPT3/4 |
|---|---|
| Series | GC600 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT3/4" (NPT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Low-pressure type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | Aluminium alloy |
| Pressure gauge | Fitted — round, psi scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC600 | G-series F.R.L. combination, 600 body — sets the port range. |
|---|---|
| 20 | Port size PT3/4". This body offers 20 = PT3/4", 25 = PT1". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-20 filter, GR600-20 regulator and GL600-20 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC600 · PT3/4" · 5 µm |
|---|---|
| One size down | GC400 |
| Two-unit equivalent | GFC600-20 |
| Build order | Filter → regulator → lubricator |
Feeding cylinders and clamps on a metal-forming press: the filter strips water and 5 um particles, the low-pressure regulator holds a steady setting, and the lubricator mists oil to the valve and cylinder seals.
A bottling or packaging line where grippers and diverters run all shift; the manual drain suits a site that already checks bowls during scheduled changeovers, and the 5 um element protects the downstream valves.
A multi-station assembly bench drawing from one header: this size 600 set conditions the drop at the point of use, and the fitted reverse/check valve holds the circuit against backflow.
Size and port set the air capacity: step up from 200 through 300, 400 and 600 as your flow demand grows, with ports from 1/8" up to 1". This unit is size 600 with NPT3/4 ports. Drain choice matters: a manual drain (this unit) means an operator opens the drain at intervals, while automatic and differential-pressure drains discharge condensate without attention. Filter grade is 40 um standard or 5 um (W) for finer protection; this unit carries the 5 um element. Gauges are offered as the embedded square type or an external round gauge with MPa, psi or bar scales; this unit has a round gauge reading in psi. Threads can be ordered in three thread types (NPT on this code). The L in the code marks a low-pressure type regulator; its exact adjustment range is not published, so confirm it with us against your set pressure. Flow is published as curves, not a single rating - ask us to check sizing against your application before ordering.
AirtacDistr lists every GC600-20 order code with its price on one page at https://airtacdistr.com/products/airtac-gc600-20-three-unit-frl
Quick checklist
The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-20 regulator with a GF600-20 filter on that branch.
AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not quote a number here. Send us your application details and we will confirm the datasheet curve and sizing for the GC600-20 before you order.
The M in the code means the filter bowl drains manually: an operator opens the drain at intervals to remove collected condensate. Automatic and differential-pressure drain options exist in the same size if you would rather not rely on manual checks - ask us when ordering.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.