verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart1 Request a QuoteQuote
AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

GC30015LF2TK AirTAC F.R.L. 3-Unit, NPT1/2, Square psi Gauge

The AirTAC GC30015LF2TK AirTAC F.R.L. 3-Unit, NPT1/2, Square psi Gauge is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$122.34 $129.84Save 5% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC300-15 drain, gauge and thread option on one page All GC300-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the GC30015LF2TK AirTAC F.R.L. 3-Unit, NPT1/2, Square psi Gauge

The AirTAC GC30015LF2TK is a three-piece F.R.L. combination: a separate air filter, a pressure regulator and an oil-mist lubricator assembled as one GC300 set. It cleans compressed air (removing water and particulate down to the standard 40 um grade), regulates downstream pressure with the low-pressure type regulator, and adds oil mist for downstream air tools and cylinders. This configuration has 1/2 inch NPT ports, a differential-pressure drain on the filter bowl, an embedded square gauge with a psi scale, a reverse/check valve fitted, and a mounting bracket included. The filter and lubricator bowls are polycarbonate (PC) on this 300 size. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing.

This is a genuine AirTAC part. The GC series is available in sizes 200, 300, 400 and 600, with port sizes from 1/8 to 1 inch, G (BSPP) or NPT thread options, automatic, manual or differential-pressure drains, a 5 um filter element (code W), gauge scale choices of MPa, psi or bar, and an optional external round gauge. Because flow is published as curves rather than a single rated figure, we confirm the datasheet and sizing figures on request before you order.

GC30015LF2TK AirTAC F.R.L. 3-Unit, NPT1/2, Square psi Gauge Technical Specifications

ModelGC30015LF2TK AirTAC F.R.L. 3-Unit, NPT1/2, Square psi Gauge
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — square, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC30015LF2TK AirTAC F.R.L. 3-Unit, NPT1/2, Square psi Gauge

GC300G-series F.R.L. combination, 300 body — sets the port range.
15Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-15 filter, GR300-15 regulator and GL300-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT1/2" · 40 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-15
Build orderFilter → regulator → lubricator

Where the GC30015LF2TK AirTAC F.R.L. 3-Unit, NPT1/2, Square psi Gauge Is Used

factory

Packaging line air supply

Mounted at the drop of a packaging machine's air main, the set removes water and debris, holds a steady low working pressure for the machine's valves, and mists oil to the pneumatic actuators running the carton-forming and sealing stations.

conveyor_belt

Conveyor drive cylinders

Feeding the air cylinders that index and divert product on a conveyor line, the unit keeps moisture and particles out of the valves, regulates line pressure with the low-pressure regulator, and lubricates the cylinder seals for smoother stroke action.

engineering

Assembly-cell air drops

Installed at a bench drop feeding air tools and clamping fixtures in an assembly cell, the combination delivers cleaned, regulated and lubricated air, with the psi gauge giving the operator a direct pressure readout at the point of use.

Is the GC30015LF2TK AirTAC F.R.L. 3-Unit, NPT1/2, Square psi Gauge the Right Station?

Start with size and port: the 300 size with NPT1/2 ports suits lines running half-inch air mains, while smaller or larger duties step to the 200, 400 or 600 sizes. Choose the drain to match maintenance access: differential-pressure (as fitted here) drains automatically across a pressure band, automatic (code A) drains continuously, and manual (code M) needs a periodic drain. The standard element is 40 um; specify W for the 5 um grade where finer filtration is needed. This unit is the low-pressure type regulator, so tell us your working pressure band and we will confirm the exact adjustment range from the datasheet. The embedded square gauge here reads in psi; MPa or bar scales and an external round gauge are alternatives. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.

Flow data for the GC300 is published as curves, not a single rated number, so please ask us to confirm sizing against your application before ordering.

AirtacDistr lists every GC300-15 order code with its price on one page at https://airtacdistr.com/products/airtac-gc300-15-three-unit-frl

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-15 regulator with a GF300-15 filter on that branch.

GC30015LF2TK AirTAC F.R.L. 3-Unit, NPT1/2, Square psi Gauge FAQ

AirTAC publishes flow for this series as performance curves rather than a single rated figure, so we do not quote one number. Tell us your application and we will confirm the flow and sizing data from the datasheet on request before you order.

The L in the code marks the low-pressure type regulator, intended for lower working-pressure duties; the exact adjustment range for this variant is not published in the standard tables, so we confirm it from the datasheet on request. The filter uses the differential-pressure drain, which discharges collected condensate automatically across a pressure band without manual intervention.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for GC30015LF2TK AirTAC F.R.L. 3-Unit, NPT1/2, Square psi Gauge

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.