verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart1 Request a QuoteQuote
AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

GC40010MLC2T AirTAC F.R.L. Combination, NPT3/8, Low-Pressure

The AirTAC GC40010MLC2T AirTAC F.R.L. Combination, NPT3/8, Low-Pressure is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/8" ports, a 40 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT3/8"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$155.22 $162.72Save 4% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC400-10 drain, gauge and thread option on one page All GC400-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the GC40010MLC2T AirTAC F.R.L. Combination, NPT3/8, Low-Pressure

The GC40010MLC2T is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one set. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. The polycarbonate bowls let you see condensate and oil level at a glance, and the manual drain is emptied by hand as part of routine maintenance.

This is a genuine AirTAC part. The GC line is available in sizes 200, 300, 400 and 600 with a choice of port sizes, three thread types (NPT on this code), differential-pressure, automatic or manual drains, 40 um or 5 um (W) filtration, standard or low-pressure regulators, and square or round gauges scaled in MPa, psi or bar. Flow is published as curves rather than a single rating, so ask us and we will confirm the datasheet figures for your application on request.

GC40010MLC2T AirTAC F.R.L. Combination, NPT3/8, Low-Pressure Technical Specifications

ModelGC40010MLC2T AirTAC F.R.L. Combination, NPT3/8, Low-Pressure
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT3/8" (NPT thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC40010MLC2T AirTAC F.R.L. Combination, NPT3/8, Low-Pressure

GC400G-series F.R.L. combination, 400 body — sets the port range.
10Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-10 filter, GR400-10 regulator and GL400-10 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · PT3/8" · 40 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-10
Build orderFilter → regulator → lubricator

Where the GC40010MLC2T AirTAC F.R.L. Combination, NPT3/8, Low-Pressure Is Used

precision_manufacturing

Pneumatic assembly presses

Feeding air cylinders and pneumatic press tools on an assembly line, where the filter removes water and particles, the low-pressure regulator holds a gentle set pressure, and the lubricator mists oil to keep cylinder seals working.

conveyor_belt

Packaging line actuation

Supplying carton-forming and wrapping machinery whose air cylinders run all shift, giving the machine clean, regulated and lubricated air from a single point of use with a visible psi gauge for operators.

factory

Plant air drop for impact tools

A wall-mounted air preparation point at a maintenance bay serving impact wrenches and air ratchets, with the bracket fixing the set to the frame, the 40 um filter catching pipe scale, and the lubricator protecting the tool motors.

Is the GC40010MLC2T AirTAC F.R.L. Combination, NPT3/8, Low-Pressure the Right Station?

Start with the port size: this unit is size 400 with NPT3/8 ports, and the step up to size 600 gives a larger port and more flow capacity if your line needs it. Choose the drain to match maintenance practice: manual (this unit) is emptied by hand, automatic drains continuously, and the differential-pressure default drains on a pressure drop. Filtration is 40 um standard; specify the W code for 5 um where finer particle removal is needed. The regulator here is the low-pressure type with a round psi gauge; square embedded gauges and MPa or bar scales are alternatives. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.

Because flow is published only as curves and not as a single rated figure, send us your application details and we will confirm sizing against the datasheet before you order.

AirtacDistr lists every GC400-10 order code with its price on one page at https://airtacdistr.com/products/airtac-gc400-10-three-unit-frl

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-10 regulator with a GF400-10 filter on that branch.

GC40010MLC2T AirTAC F.R.L. Combination, NPT3/8, Low-Pressure FAQ

AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not quote a number. Tell us your application and required flow, and we will confirm the datasheet curve figures for the GC400 at NPT3/8 on request before you order.

The M in the code GC40010MLC2T specifies a manual drain: condensate collected in the filter bowl is emptied by hand as part of routine maintenance. If you prefer the bowl to drain itself, the same size is available with an automatic drain (code A) or the differential-pressure drain that is the default, and we can quote the equivalent model on request.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for GC40010MLC2T AirTAC F.R.L. Combination, NPT3/8, Low-Pressure

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.