AirTAC 3V3 · 3/2-Way Solenoid Valve

Airtac 3V Solenoid Valves 3V308NOBT

The AirTAC Airtac 3V Solenoid Valves 3V308NOBT is a genuine 3-port 2-position (3/2) solenoid valve with 1/4 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.

  • Valve type3/2-way (3-port, 2-position)
  • Initial stateNormally open
  • Port size1/4 in
  • Coil voltageDC24V
  • Electrical entryDIN plug (DIN socket type)
  • Flow (Cv)0.62
  • Series3V3
$64.80 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac 3V Solenoid Valves 3V308NOBT

The 3V308NOBT is AirTAC's normally open 3/2 valve in the largest, highest-flow 3V body, built in an NPT1/4 configuration for imperial pipework. With power on, the outlet stays connected to supply; de-energise it and the spring return vents the line to exhaust. That makes it the natural choice for fail-vent duties, where a control fault or power cut must let a clamped part or a cylinder release rather than hold. It is direct-acting with a single solenoid and a coaxial poppet, so there is no pilot pressure needed to shift it and sealing stays tight across the full 0-0.8 MPa span, down to -102.2 kPa for vacuum service. Flow is the headliner: Cv 0.62, roughly three times the Cv 0.19 of a 3V208. The 24 V DC coil draws 6.5 W and terminates in a DIN plug socket on the coil body, keeping panel wiring standard.

Airtac 3V Solenoid Valves 3V308NOBT Technical Specifications

ModelAirtac 3V Solenoid Valves 3V308NOBT
Series3V3
Valve type3/2-way (3-port, 2-position)
FunctionDirect-acting, single solenoid, spring return
Initial stateNormally open
Port size1/4 in
ThreadNPT
Coil voltageDC24V
Electrical entryDIN plug (DIN socket type)
Coil power6.5 W
Operating pressure0-0.8 MPa (0-114 psi)
Vacuum serviceRated -102.2 kPa to 0.1 MPa
Flow coefficientCv 0.62
Temperature-20 to 70 C
ConstructionCoaxial shut-off (poppet), direct-acting, spring return
ProtectionIP65 (DIN 40050)
MediumAir, filtered by a 40 µm or finer element. Lubrication not required.

Figures follow the official AirTAC 3V3 catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

Model Code: Airtac 3V Solenoid Valves 3V308NOBT

3V3Body — sets the flow, the coil power and whether vacuum is rated.
1/4 inPort size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in.
NONormally open: air passes until the coil is energised.
DC24VCoil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V.
Electrical entry: I = flying lead, otherwise a DIN plug.
NPTPort thread. PT ships from stock; G and NPT are available to order.

What a 3/2 Valve Does

A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.

That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.

It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.

Where the Airtac 3V Solenoid Valves 3V308NOBT Is Used

precision_manufacturing

Pallet ejector on a packaging machine

A larger spring-return pusher cylinder advances pallets into a carton wrap station. NO logic vents the line and retracts the pusher whenever the DC24V output drops, so a jam or power loss leaves the conveyor path clear.

air

Chip blow-off at a CNC machining cell

High-volume air clears chips from a fixture between cycles. The Cv 0.62 bore supports the wide blast nozzle, and the normally open function purges for as long as 24 V power stays on - a fault simply stops the blast.

science

Vacuum release on a PCB router table

Big vacuum cups hold blank boards on the bed. The valve, rated -102.2 kPa to 0.1 MPa, sits in the vacuum line and, being normally open, it holds continuity until energised - wire it so the break command energises the coil and the spring return vents the cup to release the board.

Is the Airtac 3V Solenoid Valves 3V308NOBT the Right Part?

Pick the 3V308NOBT when your panel runs 24 V DC, the machine uses NPT fittings and you need a normally open function with real flow headroom. If NO is the wrong fail state, choose the NC version of the same body instead. Step down to a 3V2 (Cv 0.18-0.19, 1/8in or 1/4in, also vacuum-rated) when 0.62 is more coefficient than the job needs, to the 3V2M (Cv 0.1) when a compact multi-station manifold beats raw flow, or to the 3V1 (3.0 W on DC24V) for the smallest low-power circuits. Confirm five points before ordering: port size and thread (this code is NPT; PT is the family default and G/BSPP is a catalogue option), NC or NO, coil voltage, electrical entry (DIN plug here, flying lead with the I suffix), and whether vacuum duty applies. If the target is a double-acting cylinder, move to the AirTAC 4V 5-port series instead.

Confirm before you order

  • ✓ Port size and thread (PT from stock; G / NPT to order)
  • ✓ Initial state — NC or NO, ordered up front
  • ✓ Coil voltage matches your controller output
  • ✓ Electrical entry — DIN plug or flying lead
  • ✓ Single valve, bare base, or complete assembly
  • ✓ Single-acting duty, not double-acting
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Stay within 0-0.8 MPa (0-114 psi) operating pressure.
  • check Match the coil voltage to your controller output.
  • check Use the manual override to test before powering up.
  • check Leave the exhaust port clear, or fit a silencer.
  • check Wiring by qualified personnel, per AirTAC documentation.

Airtac 3V Solenoid Valves 3V308NOBT FAQ

It is a 3/2-way, direct-acting, single-solenoid, spring-return valve in normally open form. Port NPT1/4. Flow coefficient Cv 0.62, the highest in the AirTAC 3V range. Operating pressure 0-0.8 MPa, with vacuum service rated -102.2 kPa to 0.1 MPa. Temperature range -20 to 70 C. Coil power 6.5 W on DC24V (AC versions of the body are 10 VA). Protection class IP65 (DIN 40050). Air should be filtered to 40 um or finer; lubrication is not required. A manual override is fitted for commissioning.

It feeds or vents one line, so it suits single-acting (spring-return) cylinders, blow-off, clamping, vacuum switching and piloting a larger valve. It cannot drive a double-acting cylinder - that takes a 5-port valve such as the AirTAC 4V series. On the thread: the T in this order code selects the NPT option for imperial fittings, while PT tapered is the standard thread of the 3V3 family and G/BSPP parallel is also a catalogue choice to order. Choose NO over NC when the circuit must pass air or keep the vacuum path open while de-energised, and vent or seal only when the 24 V coil is energised.

verified

Authorized Export Seller

Genuine AirTAC parts produced by the AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac 3V Solenoid Valves 3V308NOBT

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 3V308NOBT and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.