verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC 3V2M · Valve Manifold Assembly

Airtac 3V2M Solenoid Valve 3V2MNCAI-1F

The AirTAC Airtac 3V2M Solenoid Valve 3V2MNCAI-1F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.

  • Valve type3/2-way (3-port, 2-position)
  • Initial stateNormally closed
  • Port size1/8 in
  • Coil voltageAC220V
  • Electrical entryFlying lead (lead-out wire type)
  • Stations1
  • Flow (Cv)0.1
  • Series3V2M
$50.24 $55.18Save 8% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every 3V2M manifold set voltage, station and exhaust option on one page All 3V2M manifold set codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac 3V2M Solenoid Valve 3V2MNCAI-1F

The 3V2MNCAI-1F is a complete single-station assembly: one normally closed 3/2 valve body with an AC220V solenoid and flying-lead entry, factory mounted on a 1F base with PT threads. Until the coil is energised the outlet stays vented to exhaust; energise it and the valve feeds the outlet from the supply, and the spring returns it to vent when power drops. The construction is direct acting with a coaxial shut-off poppet, giving tight sealing at Cv 0.1.

The 1F base is the starting block of the 3V2M manifold system: one shared air supply, one shared wiring run, and free expansion as your circuit grows. Wiring is by pre-fitted lead-out wire rather than a DIN socket, which speeds panel routing. A manual override is fitted for set-up and commissioning. Note that the NC state cannot be converted to NO after purchase - order the initial state you need.

Airtac 3V2M Solenoid Valve 3V2MNCAI-1F Technical Specifications

ModelAirtac 3V2M Solenoid Valve 3V2MNCAI-1F
Series3V2M
Valve type3/2-way (3-port, 2-position)
FunctionDirect-acting, single solenoid, spring return
Initial stateNormally closed
Item formComplete assembly — 1 valves on a shared base
ExhaustCentralised exhaust
Port size1/8 in
ThreadPT
Coil voltageAC220V
Electrical entryFlying lead (lead-out wire type)
Coil power7 VA
Operating pressure0-0.8 MPa (0-114 psi)
Vacuum serviceNot rated for vacuum
Flow coefficientCv 0.1
Temperature-20 to 70 C
ConstructionCoaxial shut-off (poppet), base-mounted, spring return
ProtectionIP65 (DIN 40050)
MediumAir, filtered by a 40 µm or finer element. Lubrication not required.

Figures follow the official AirTAC 3V2M catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

The initial state cannot be changed after ordering. 3V2M uses a dedicated base gasket, and reversing or flipping that gasket does not convert NC to NO. Order the state you need up front.

Model Code: Airtac 3V2M Solenoid Valve 3V2MNCAI-1F

3V2MBody — sets the flow, the coil power and whether vacuum is rated.
1/8 inPort size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in.
NCNormally closed: no air at the outlet until the coil is energised.
AC220VCoil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V.
IElectrical entry: I = flying lead, otherwise a DIN plug.
1F1 stations in one assembly, centralised exhaust.
PTPort thread. PT ships from stock; G and NPT are available to order.

What a 3/2 Valve Does

A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.

That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.

It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.

Where the Airtac 3V2M Solenoid Valve 3V2MNCAI-1F Is Used

engineering

Bench test rig circuits

Switching air to a single test fixture on an R&D bench, wired by lead-out wire, with the option to grow the manifold station by station later.

settings_input_component

Pilot duty for process valves

Driving the pilot port of a larger process valve in a water treatment skid, where each 3V2M station switches one pilot line off a shared supply.

bolt

Clamping on an assembly jig

One spring-return clamp cylinder on an electronics fixture jig, released automatically whenever the AC220V coil is de-energised.

Is the Airtac 3V2M Solenoid Valve 3V2MNCAI-1F the Right Part?

Match five points before ordering: initial state (NC here - the outlet is vented until energised), coil voltage (AC220V at 7 VA), electrical entry (flying lead instead of a DIN plug), station count (1F, expandable later) and exhaust type (centralised on this base, PT thread; G and NPT are order items). The NC/NO state is fixed at manufacture - the dedicated base gasket cannot be flipped or otherwise converted, so buy the state you need.

Flow through a 3V2M base is Cv 0.1. If a circuit needs more, an individually ported 3V2 gives Cv 0.18 at 1/8 in or 0.19 at 1/4 in and is vacuum rated; 3V3 reaches Cv 0.62 at 1/4 in for the highest flow in the 3V range. Where the duty is small, 3V1 is the low-power pick at 3.0 W DC. This valve drives single-acting cylinders and pilot ports only - for double-acting cylinders use the 5-port AirTAC 4V series.

Confirm before you order

  • ✓ Port size and thread (PT from stock; G / NPT to order)
  • ✓ Initial state — NC or NO, ordered up front
  • ✓ Coil voltage matches your controller output
  • ✓ Electrical entry — DIN plug or flying lead
  • ✓ Single valve, bare base, or complete assembly
  • ✓ Single-acting duty, not double-acting
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Stay within 0-0.8 MPa (0-114 psi) operating pressure.
  • check Match the coil voltage to your controller output.
  • check Use the manual override to test before powering up.
  • check Leave the exhaust port clear, or fit a silencer.
  • check Blank any unused station on the base before pressurising.
  • check Wiring by qualified personnel, per AirTAC documentation.

Airtac 3V2M Solenoid Valve 3V2MNCAI-1F FAQ

It is a 3/2 normally closed assembly with a Cv 0.1 flow coefficient, operating pressure 0-0.8 MPa (0-114 psi), temperature range -20 to 70 C, coil power of 7 VA on AC and 7.0 W on DC, and IP65 (DIN 40050) protection. Ports are PT1/8 on a PT base; G and NPT threads are available to order.

No. The 3V2M uses a dedicated base gasket, and reversing or flipping that gasket does not change the initial state - the catalogue states this explicitly. Order NC or NO correctly at purchase: NC keeps the outlet vented until energised, while the NO version (3V2MNOAI-1F) passes air until energised.

verified

Authorized Export Seller

Genuine AirTAC parts produced by the AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac 3V2M Solenoid Valve 3V2MNCAI-1F

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 3V2MNCAI-1F and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.