AirTAC 3V2M · Valve Manifold Assembly

Airtac 3V2M Solenoid Valve 3V2MNCAI-20F

The AirTAC Airtac 3V2M Solenoid Valve 3V2MNCAI-20F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.

  • Valve type3/2-way (3-port, 2-position)
  • Initial stateNormally closed
  • Port size1/8 in
  • Coil voltageAC220V
  • Electrical entryFlying lead (lead-out wire type)
  • Stations20
  • Flow (Cv)0.1
  • Series3V2M
$813.65 $837.51Save 2% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every 3V2M manifold set voltage, station and exhaust option on one page All 3V2M manifold set codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac 3V2M Solenoid Valve 3V2MNCAI-20F

Twenty normally closed 3/2 valves, each with its own AC220V coil on a flying lead, come factory mounted on a single 20F base in the 3V2MNCAI-20F. Every station stays vented at the outlet until its coil is energised. Mind the electrical budget: each AC coil draws 7 VA, so a fully populated bank with all twenty valves energised at once presents about 140 VA - size the supply for that worst case, not for one station.

Because supply and wiring are shared across the block, troubleshooting is quick: one feed, one wiring run, and each valve is a plug-in element on the manifold. All stations vent through one centralised exhaust port. A manual override on each valve aids commissioning. The NC state is fixed by the dedicated base gasket and cannot be changed after purchase.

Airtac 3V2M Solenoid Valve 3V2MNCAI-20F Technical Specifications

ModelAirtac 3V2M Solenoid Valve 3V2MNCAI-20F
Series3V2M
Valve type3/2-way (3-port, 2-position)
FunctionDirect-acting, single solenoid, spring return
Initial stateNormally closed
Item formComplete assembly — 20 valves on a shared base
ExhaustCentralised exhaust
Port size1/8 in
ThreadPT
Coil voltageAC220V
Electrical entryFlying lead (lead-out wire type)
Coil power7 VA
Operating pressure0-0.8 MPa (0-114 psi)
Vacuum serviceNot rated for vacuum
Flow coefficientCv 0.1
Temperature-20 to 70 C
ConstructionCoaxial shut-off (poppet), base-mounted, spring return
ProtectionIP65 (DIN 40050)
MediumAir, filtered by a 40 µm or finer element. Lubrication not required.

Figures follow the official AirTAC 3V2M catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

The initial state cannot be changed after ordering. 3V2M uses a dedicated base gasket, and reversing or flipping that gasket does not convert NC to NO. Order the state you need up front.

Model Code: Airtac 3V2M Solenoid Valve 3V2MNCAI-20F

3V2MBody — sets the flow, the coil power and whether vacuum is rated.
1/8 inPort size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in.
NCNormally closed: no air at the outlet until the coil is energised.
AC220VCoil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V.
IElectrical entry: I = flying lead, otherwise a DIN plug.
20F20 stations in one assembly, centralised exhaust.
PTPort thread. PT ships from stock; G and NPT are available to order.

What a 3/2 Valve Does

A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.

That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.

It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.

Where the Airtac 3V2M Solenoid Valve 3V2MNCAI-20F Is Used

conveyor_belt

Sorting diverter gates

Twenty spring-return gates on a parcel sorting conveyor, each one flipped by its own manifold station and dropped back by the spring when the coil drops.

factory

Bottling line reject ejectors

Reject pushers along a bottling line, one station per lane, each normally vented so no bottle is pushed unless its coil is deliberately energised.

precision_manufacturing

CNC turret tool clamps

Clamping and unclamping individual tool pockets on a turret or tool magazine, one 3/2 station per pocket off a single shared supply.

Is the Airtac 3V2M Solenoid Valve 3V2MNCAI-20F the Right Part?

For twenty stations, plan the electrical side first: 20 x 7 VA = 140 VA if every AC220V coil is live simultaneously, so verify your supply and wiring gauge against the full bank. Then match the five ordering points: state (NC), voltage (AC220V), entry (flying lead), station count (20F) and exhaust (centralised, PT thread; G and NPT to order). NC/NO cannot be converted later - the dedicated base gasket does not swap states.

At Cv 0.1 per station, the manifold trades flow for density. Any single station needing more air is better served by an individually ported 3V2 (Cv 0.18 at 1/8 in, 0.19 at 1/4 in, vacuum rated) or by 3V3 at Cv 0.62 for the top flow in the range; small low-power duties can drop to 3V1 at 3.0 W DC. These valves drive single-acting cylinders only - double-acting cylinders need the 5-port AirTAC 4V series.

Confirm before you order

  • ✓ Port size and thread (PT from stock; G / NPT to order)
  • ✓ Initial state — NC or NO, ordered up front
  • ✓ Coil voltage matches your controller output
  • ✓ Electrical entry — DIN plug or flying lead
  • ✓ Single valve, bare base, or complete assembly
  • ✓ Single-acting duty, not double-acting
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Stay within 0-0.8 MPa (0-114 psi) operating pressure.
  • check Match the coil voltage to your controller output.
  • check Use the manual override to test before powering up.
  • check Leave the exhaust port clear, or fit a silencer.
  • check Blank any unused station on the base before pressurising.
  • check Wiring by qualified personnel, per AirTAC documentation.

Airtac 3V2M Solenoid Valve 3V2MNCAI-20F FAQ

Each of the twenty stations is a 3/2 NC valve with Cv 0.1, pressure range 0-0.8 MPa (0-114 psi), temperature -20 to 70 C, coil power 7 VA on AC or 7.0 W on DC, and IP65 (DIN 40050) protection. The base thread is PT; G and NPT are order options.

Each 3/2 station has three ports (supply, outlet, exhaust) and either feeds the outlet or vents it, so it suits single-acting spring-return cylinders, air blow, clamping and pilot duty. It cannot drive a double-acting cylinder - that requires a 5-port valve such as the AirTAC 4V series.

verified

Authorized Export Seller

Genuine AirTAC parts produced by the AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac 3V2M Solenoid Valve 3V2MNCAI-20F

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 3V2MNCAI-20F and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.