verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC 3V2M · Valve Manifold Assembly

Airtac 3V2M Solenoid Valve 3V2MNCB-13F

The AirTAC Airtac 3V2M Solenoid Valve 3V2MNCB-13F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.

  • Valve type3/2-way (3-port, 2-position)
  • Initial stateNormally closed
  • Port size1/8 in
  • Coil voltageDC24V
  • Electrical entryDIN plug (DIN socket type)
  • Stations13
  • Flow (Cv)0.1
  • Series3V2M
$532.41 $549.30Save 3% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every 3V2M manifold set voltage, station and exhaust option on one page All 3V2M manifold set codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac 3V2M Solenoid Valve 3V2MNCB-13F

Thirteen stations on one 3V2M base is where manifold density really pays - and where its flow ceiling shows. Each 3/2 normally closed path through the base is Cv 0.1, versus Cv 0.18 for an individually-ported 3V2, because air must cross the shared supply gallery. For thirteen light-duty single-acting or blow duties, that is rarely a constraint.

Each DC24V coil draws 7.0 W, so a fully energised 13-station assembly approaches 91 W, near 3.8 A at 24 V. Valves are direct-acting, single-solenoid, spring-return, with coaxial poppet sealing and a manual override for commissioning. All station vents combine at one centralised exhaust, ports are PT1/8, and protection is IP65 (DIN 40050).

Airtac 3V2M Solenoid Valve 3V2MNCB-13F Technical Specifications

ModelAirtac 3V2M Solenoid Valve 3V2MNCB-13F
Series3V2M
Valve type3/2-way (3-port, 2-position)
FunctionDirect-acting, single solenoid, spring return
Initial stateNormally closed
Item formComplete assembly — 13 valves on a shared base
ExhaustCentralised exhaust
Port size1/8 in
ThreadPT
Coil voltageDC24V
Electrical entryDIN plug (DIN socket type)
Coil power7.0 W
Operating pressure0-0.8 MPa (0-114 psi)
Vacuum serviceNot rated for vacuum
Flow coefficientCv 0.1
Temperature-20 to 70 C
ConstructionCoaxial shut-off (poppet), base-mounted, spring return
ProtectionIP65 (DIN 40050)
MediumAir, filtered by a 40 µm or finer element. Lubrication not required.

Figures follow the official AirTAC 3V2M catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

The initial state cannot be changed after ordering. 3V2M uses a dedicated base gasket, and reversing or flipping that gasket does not convert NC to NO. Order the state you need up front.

Model Code: Airtac 3V2M Solenoid Valve 3V2MNCB-13F

3V2MBody — sets the flow, the coil power and whether vacuum is rated.
1/8 inPort size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in.
NCNormally closed: no air at the outlet until the coil is energised.
DC24VCoil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V.
—Electrical entry: I = flying lead, otherwise a DIN plug.
13F13 stations in one assembly, centralised exhaust.
PTPort thread. PT ships from stock; G and NPT are available to order.

What a 3/2 Valve Does

A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.

That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.

It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.

Where the Airtac 3V2M Solenoid Valve 3V2MNCB-13F Is Used

valve

Water-treatment skid pilot bank

Thirteen pilot lines feeding process valves are switched from one manifold, sharing a single DC24V supply and one filtered-air feed.

build

Modular fixture table, 13 swing clamps

Each clamp cylinder gets its own switching station, and the shared wiring makes an intermittent clamp easy to isolate and replace.

air

Can-wash line blow-off header

Thirteen on/off air jets strip rinse water from passing cans; NC valves guarantee every jet is dead the moment the line stops.

Is the Airtac 3V2M Solenoid Valve 3V2MNCB-13F the Right Part?

Lock in five things at order time: NC initial state (unconvertible later - the dedicated base gasket does not reverse it), DC24V, DIN plug entry, 13 stations, centralised exhaust. PT is the standard thread across 3V2M; G and NPT are order codes, not workshop changes.

When one station needs more than Cv 0.1, feed it from a standalone 3V2 (Cv 0.18 at 1/8 in, 0.19 at 1/4 in, vacuum-rated) or a 3V3 (Cv 0.62 at 1/4 in, vacuum-rated); when a duty is trivial but power is scarce, 3V1 runs at 3.0 W DC. Double-acting cylinders are outside any 3/2 valve - specify the AirTAC 4V 5-port series.

Confirm before you order

  • ✓ Port size and thread (PT from stock; G / NPT to order)
  • ✓ Initial state — NC or NO, ordered up front
  • ✓ Coil voltage matches your controller output
  • ✓ Electrical entry — DIN plug or flying lead
  • ✓ Single valve, bare base, or complete assembly
  • ✓ Single-acting duty, not double-acting
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Stay within 0-0.8 MPa (0-114 psi) operating pressure.
  • check Match the coil voltage to your controller output.
  • check Use the manual override to test before powering up.
  • check Leave the exhaust port clear, or fit a silencer.
  • check Blank any unused station on the base before pressurising.
  • check Wiring by qualified personnel, per AirTAC documentation.

Airtac 3V2M Solenoid Valve 3V2MNCB-13F FAQ

Cv 0.1 per path, 0-0.8 MPa (0-114 psi) pressure, -20 to 70 C temperature, IP65 (DIN 40050), and 7.0 W per DC24V coil - about 91 W if all thirteen stations energise together. AC versions of 3V2M draw 7 VA per coil. Air filtration should be 40 um or finer.

Each station passes no air to its outlet until its coil is energised; on de-energising, the spring vents the outlet to the shared exhaust. This state is chosen at purchase and cannot be changed by flipping the base gasket or by any other field method - order the NO code if the opposite behaviour is needed.

verified

Authorized Export Seller

Genuine AirTAC parts produced by the AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac 3V2M Solenoid Valve 3V2MNCB-13F

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 3V2MNCB-13F and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.