The AirTAC Airtac 3V2M Solenoid Valve 3V2MNCB-16F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.

  • Valve type3/2-way (3-port, 2-position)
  • Initial stateNormally closed
  • Port size1/8 in
  • Coil voltageDC24V
  • Electrical entryDIN plug (DIN socket type)
  • Stations16
  • Flow (Cv)0.1
  • Series3V2M
$652.93 $672.81Save 2% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every 3V2M manifold set voltage, station and exhaust option on one page All 3V2M manifold set codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac 3V2M Solenoid Valve 3V2MNCB-16F

Sixteen normally closed 3/2 valves, one base: the 3V2MNCB-16F is a 16-station assembly with DC24V coils on DIN plugs, a centralised exhaust port and PT1/8 connections. Every body is a direct-acting, single-solenoid, spring-return unit built around a coaxial shut-off poppet. With centralised exhaust, all sixteen stations vent through the base's common exhaust, which keeps piping short - route that single exhaust line where waste air and noise are acceptable.

Because the exhaust is shared, one silencer and one duct serve the whole bank. The NC logic means each outlet stays vented until its coil is energised, which is the safe default for clamps and gates that must release on power loss. IP65 (DIN 40050) coil protection and a manual override on each station round out the package. And one warning the catalogue states plainly: reversing the dedicated base gasket does not convert NC to NO - the state is fixed by the valves you order.

Airtac 3V2M Solenoid Valve 3V2MNCB-16F Technical Specifications

ModelAirtac 3V2M Solenoid Valve 3V2MNCB-16F
Series3V2M
Valve type3/2-way (3-port, 2-position)
FunctionDirect-acting, single solenoid, spring return
Initial stateNormally closed
Item formComplete assembly — 16 valves on a shared base
ExhaustCentralised exhaust
Port size1/8 in
ThreadPT
Coil voltageDC24V
Electrical entryDIN plug (DIN socket type)
Coil power7.0 W
Operating pressure0-0.8 MPa (0-114 psi)
Vacuum serviceNot rated for vacuum
Flow coefficientCv 0.1
Temperature-20 to 70 C
ConstructionCoaxial shut-off (poppet), base-mounted, spring return
ProtectionIP65 (DIN 40050)
MediumAir, filtered by a 40 µm or finer element. Lubrication not required.

Figures follow the official AirTAC 3V2M catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

The initial state cannot be changed after ordering. 3V2M uses a dedicated base gasket, and reversing or flipping that gasket does not convert NC to NO. Order the state you need up front.

Model Code: Airtac 3V2M Solenoid Valve 3V2MNCB-16F

3V2MBody — sets the flow, the coil power and whether vacuum is rated.
1/8 inPort size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in.
NCNormally closed: no air at the outlet until the coil is energised.
DC24VCoil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V.
—Electrical entry: I = flying lead, otherwise a DIN plug.
16F16 stations in one assembly, centralised exhaust.
PTPort thread. PT ships from stock; G and NPT are available to order.

What a 3/2 Valve Does

A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.

That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.

It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.

Where the Airtac 3V2M Solenoid Valve 3V2MNCB-16F Is Used

settings_input_component

PLC I/O air interface

Sixteen NC outputs on one manifold mirror sixteen PLC digital points, each switching a pilot or clamp line from a common DC24V rail.

speed

Stamping press feed gates

High-cycle single-acting feed and eject gates around a press, releasing safely to the shared exhaust whenever a coil drops out.

science

Lab automation manifold

Sixteen on/off air functions - purges, lifts, caps - packed into one base inside a compact analytical instrument enclosure.

Is the Airtac 3V2M Solenoid Valve 3V2MNCB-16F the Right Part?

This code fixes five choices for you: NC initial state, DC24V coil, DIN plug entry, 16 stations and centralised exhaust, on PT1/8 (PT is the standard thread here; order G or NPT as a catalogue option). If your machine would be noisier or dirtier with a shared exhaust, the same bank exists with independent exhaust - add D to the code. NC/NO cannot be changed after delivery.

Flow is Cv 0.1 per station because air passes through the base - that is the trade-off for 16 valves on one manifold. A single high-flow station is better served by a separate 3V2 (Cv 0.18 at 1/8 in, Cv 0.19 at 1/4 in, vacuum-rated) or a 3V3 (Cv 0.62, 1/4 in, vacuum-rated); 3V1 at 3.0 W DC suits light, low-power duty. Double-acting actuators need the AirTAC 4V 5-port series, not this valve.

Confirm before you order

  • ✓ Port size and thread (PT from stock; G / NPT to order)
  • ✓ Initial state — NC or NO, ordered up front
  • ✓ Coil voltage matches your controller output
  • ✓ Electrical entry — DIN plug or flying lead
  • ✓ Single valve, bare base, or complete assembly
  • ✓ Single-acting duty, not double-acting
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Stay within 0-0.8 MPa (0-114 psi) operating pressure.
  • check Match the coil voltage to your controller output.
  • check Use the manual override to test before powering up.
  • check Leave the exhaust port clear, or fit a silencer.
  • check Blank any unused station on the base before pressurising.
  • check Wiring by qualified personnel, per AirTAC documentation.

Airtac 3V2M Solenoid Valve 3V2MNCB-16F FAQ

The base (no D code) routes all sixteen stations to one common exhaust, so a single silencer serves the bank and piping stays minimal. Specifications: 3/2 NC, direct-acting, spring return, Cv 0.1, pressure 0-0.8 MPa, temperature -20 to 70 C, DC coil 7.0 W per station, IP65 (DIN 40050), ports PT1/8.

No. 3V2M uses a dedicated base gasket and flipping that gasket does not convert NC to NO - the manufacturer states this explicitly. The normally closed function is built into the valve bodies as ordered, so select NC only after confirming the de-energised = vented behaviour your machine requires.

verified

Authorized Export Seller

Genuine AirTAC parts produced by the AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac 3V2M Solenoid Valve 3V2MNCB-16F

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 3V2MNCB-16F and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.