The AirTAC Airtac 3V2M Solenoid Valve 3V2MNCB-19F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
Nineteen normally closed 3/2 valves ride on a single 3V2M base in this assembly, sharing one PT1/8 air feed and one DIN-plug wiring loom at DC24V. Every valve is a direct-acting poppet unit with spring return: energise a coil to feed its outlet, drop the coil and the spring seats the poppet, venting the outlet to the centralised exhaust gallery.
Two engineering numbers decide whether this suits your panel. First, flow: Cv 0.1 per station, lower than a stand-alone 3V2 because the path runs through the base. Second, the worst-case load: nineteen coils at 7.0 W is 133 W, near 5.5 A on a 24 V rail, so size the PSU and DIN-rail wiring for an all-on condition, not the typical few-coils-on case.
| Model | Airtac 3V2M Solenoid Valve 3V2MNCB-19F |
|---|---|
| Series | 3V2M |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Initial state | Normally closed |
| Item form | Complete assembly — 19 valves on a shared base |
| Exhaust | Centralised exhaust |
| Port size | 1/8 in |
| Thread | PT |
| Coil voltage | DC24V |
|---|---|
| Electrical entry | DIN plug (DIN socket type) |
| Coil power | 7.0 W |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Not rated for vacuum |
| Flow coefficient | Cv 0.1 |
| Temperature | -20 to 70 C |
| Construction | Coaxial shut-off (poppet), base-mounted, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V2M catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V2M | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| 1/8 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| NC | Normally closed: no air at the outlet until the coil is energised. |
| DC24V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| — | Electrical entry: I = flying lead, otherwise a DIN plug. |
| 19F | 19 stations in one assembly, centralised exhaust. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
Nineteen pilot lines on a chemical dosing skid are each opened by one station, with the NC layout venting every pilot the moment the skid is shut down.
An automated analytical instrument uses single-acting air pistons to divert sample probes; one 3V2M station per probe keeps control wiring to a single 24 V run.
Nineteen eject stations along an assembly line blow or push finished parts off their nests, each firing only while its coil is energised.
A normally closed bank like this is the right default wherever a power failure should leave the machine vented and safe - outlets pass air only while the coil is held. Remember that NC and NO are order-time decisions on 3V2M; there is no field conversion, and turning the base gasket around achieves nothing. If one duty outgrows the base, run an individual 3V2 (Cv 0.18 at 1/8, 0.19 at 1/4, vacuum-rated) or a 3V3 (Cv 0.62, 1/4, vacuum-rated) in that circuit, and pick 3V1 (3.0 W DC) for low-power duties.
Confirm five things at ordering: NC state, DC24V, DIN plug entry, nineteen stations, centralised exhaust, plus thread (PT as standard; G or NPT are catalogue options). Double-acting cylinders fall outside 3/2 function - specify the AirTAC 4V series instead.
Confirm before you order
Nineteen NC 3/2 stations on one base, PT1/8 port, Cv 0.1 flow coefficient per station, 0-0.8 MPa operating pressure, -20 to 70 C fluid temperature, DC24V coils drawing 7.0 W each (133 W worst case), IP65 (DIN 40050) protection. Air must be filtered to 40 um or finer; lubrication is not required.
With centralised exhaust every station vents into one shared gallery and one silencer point, which keeps the machine exterior tidy and cuts noise hardware. The trade-off is that exhaust air from all nineteen valves mixes, so if you need to capture, monitor or separately silence individual station exhausts, order the -D independent-exhaust version instead. Note that a 3/2 valve drives single-acting cylinders only; double-acting actuators need the AirTAC 4V series.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.