The AirTAC Airtac 3V2M Solenoid Valve 3V2MNCB-6F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
Six spring-return 3/2 NC valves on one base: 3V2MNCB-6F gives you six independent on/off air outputs from a single PT1/8 supply and a single wiring run. The coaxial poppet construction seats well, and each direct-acting DC24V coil draws 7.0 W, so a worst-case all-on figure of about 42 W, near 1.75 A at 24 V, should shape your power supply choice.
Exhaust from all six stations is centralised through the base, keeping piping tidy. Flow is Cv 0.1 per station, temperature range -20 to 70 C, and coil protection IP65. The normally closed state is chosen at order and cannot be reversed afterwards by flipping the dedicated base gasket or by any other field method.
| Model | Airtac 3V2M Solenoid Valve 3V2MNCB-6F |
|---|---|
| Series | 3V2M |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Initial state | Normally closed |
| Item form | Complete assembly — 6 valves on a shared base |
| Exhaust | Centralised exhaust |
| Port size | 1/8 in |
| Thread | PT |
| Coil voltage | DC24V |
|---|---|
| Electrical entry | DIN plug (DIN socket type) |
| Coil power | 7.0 W |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Not rated for vacuum |
| Flow coefficient | Cv 0.1 |
| Temperature | -20 to 70 C |
| Construction | Coaxial shut-off (poppet), base-mounted, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V2M catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V2M | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| 1/8 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| NC | Normally closed: no air at the outlet until the coil is energised. |
| DC24V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| — | Electrical entry: I = flying lead, otherwise a DIN plug. |
| 6F | 6 stations in one assembly, centralised exhaust. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
Six spring-return ejector or core-pull cylinders on an injection mould tool, sequenced from one 6-station manifold.
Quick-action clamps on a press brake that release the sheet the instant power is lost, since the NC valve vents the outlet.
Purge-air valves in a paint booth interlock, all venting to a safe state through one centralised exhaust.
Five points to lock in: state NC (ordered once, unchangeable afterwards - reversing the base gasket does not convert it), voltage DC24V, entry DIN plug, station count 6, exhaust centralised, and thread PT standard with G or NPT as order options. Cv is 0.1 per station through the base; for a higher-flow station, an individual 3V2 offers Cv 0.18 at 1/8 and 0.19 at 1/4 (vacuum rated), 3V3 offers Cv 0.62 at 1/4 (vacuum rated), and 3V1 cuts coil power to 3.0 W DC.
Double-acting cylinders need five ports, not three - route that requirement to the AirTAC 4V series.
Confirm before you order
Per valve: Cv 0.1, 0-0.8 MPa (0-114 psi) operating pressure, -20 to 70 C temperature, PT1/8 ports, IP65 (DIN 40050). Coil power is 7.0 W at DC24V - about 42 W if all six run at once (AC coils in the family are 7 VA). Supply air filtered to 40 um or finer; no lubrication needed.
They are 3/2 valves with three ports, so they drive single-acting spring-return cylinders, blow duty and pilots - not double-acting cylinders, which need a 5-port valve from the AirTAC 4V series. Also note the NC state is ordered, not converted: reversing the dedicated base gasket does not change NC to NO.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.