The AirTAC Airtac 3V2M Solenoid Valve 3V2MNCB-8F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
Eight NC 3/2 valve bodies on one dedicated 8F base make the 3V2MNCB-8F a compact switching block for spring-return circuits. Direct-acting poppets with spring return keep the outlet vented until each DC24V coil is energised, and the shared supply and shared wiring mean one air connection and one cable run for all eight stations.
Power is the figure to plan around here: 7.0 W per DIN plug coil means 56 W, roughly 2.3 A at 24 V, when every station is held energised - size the PSU for that worst case. Each stage flows Cv 0.1 across 0-0.8 MPa, protection is IP65 (DIN 40050), and PT1/8 is standard (G or NPT to order).
| Model | Airtac 3V2M Solenoid Valve 3V2MNCB-8F |
|---|---|
| Series | 3V2M |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Initial state | Normally closed |
| Item form | Complete assembly — 8 valves on a shared base |
| Exhaust | Centralised exhaust |
| Port size | 1/8 in |
| Thread | PT |
| Coil voltage | DC24V |
|---|---|
| Electrical entry | DIN plug (DIN socket type) |
| Coil power | 7.0 W |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Not rated for vacuum |
| Flow coefficient | Cv 0.1 |
| Temperature | -20 to 70 C |
| Construction | Coaxial shut-off (poppet), base-mounted, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V2M catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V2M | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| 1/8 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| NC | Normally closed: no air at the outlet until the coil is energised. |
| DC24V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| — | Electrical entry: I = flying lead, otherwise a DIN plug. |
| 8F | 8 stations in one assembly, centralised exhaust. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
Eight NC valves vent eight product ports in sequence; centralised exhaust keeps one silenced outlet on the rig frame.
Use individual stations to feed or vent spring-return register rollers, with the manual override aiding web set-up.
NC valves hold gates vented between shots, so a control fault stops the sorter in a known, safe state.
At Cv 0.1 this eight-station block trades some flow for density; stations needing more should take an individual 3V2 valve (Cv 0.18 at 1/8 in, 0.19 at 1/4 in, vacuum-rated) or a 3V3 (Cv 0.62 at 1/4 in). If the duty is light and power is the constraint, 3V1 at 3.0 W DC halves the coil load per point.
Fix five choices at order time: NC initial state, DC24V, DIN plug entry, eight stations, centralised exhaust. The NC function cannot be reworked after purchase - the dedicated base gasket converts nothing. Driving double-acting cylinders? Move to the AirTAC 4V series.
Confirm before you order
Eight NC 3/2 direct-acting poppet valves, single solenoid, spring return, on a shared 8F base. Cv 0.1 per station, 0-0.8 MPa (0-114 psi), -20 to 70 C, DC24V coils at 7.0 W each, IP65 (DIN 40050), PT1/8, centralised exhaust. Air filtered to 40 um or finer.
Every 3V2M DC coil takes 7.0 W, so eight energised stations draw 56 W - about 2.3 A at 24 V. Add a margin for future stations before choosing the power supply. The coil count, not the base, sets this figure.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.