The AirTAC Airtac 3V2M Solenoid Valve 3V2MNCB-8FD is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
The 3V2MNCB-8FD pairs eight normally closed 3/2 valve bodies with an 8FD base whose D suffix gives every station its own exhaust port. Instead of sharing one silenced outlet, each valve vents where you pipe it - through its own silencer, into a collector, or to a safe area - which also makes a leaking or stuck station easy to isolate by ear or by hose.
Valves are direct-acting, single solenoid, spring return, coaxial shut-off; outlets stay vented until each DC24V DIN plug coil is energised. Eight coils at 7.0 W total 56 W, near 2.3 A at 24 V with all on. Flow is Cv 0.1 per stage, pressure 0-0.8 MPa, IP65. PT1/8 thread standard; G and NPT are order options.
| Model | Airtac 3V2M Solenoid Valve 3V2MNCB-8FD |
|---|---|
| Series | 3V2M |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Initial state | Normally closed |
| Item form | Complete assembly — 8 valves on a shared base |
| Exhaust | Independent exhaust |
| Port size | 1/8 in |
| Thread | PT |
| Coil voltage | DC24V |
|---|---|
| Electrical entry | DIN plug (DIN socket type) |
| Coil power | 7.0 W |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Not rated for vacuum |
| Flow coefficient | Cv 0.1 |
| Temperature | -20 to 70 C |
| Construction | Coaxial shut-off (poppet), base-mounted, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V2M catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V2M | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| 1/8 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| NC | Normally closed: no air at the outlet until the coil is energised. |
| DC24V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| — | Electrical entry: I = flying lead, otherwise a DIN plug. |
| 8F | 8 stations in one assembly, independent exhaust. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
Pipe each NC valve discharge from reagent-handling actuators into a dedicated extraction line, one port per station.
Eight NC valves drive spring-return grippers and box pushers; independent exhaust keeps each zone discharge clear of sensors.
Vent each test fixture separately after a pressure hold, so a failing unit is heard at its own exhaust port.
Pick the -8FD over the -8F when vent routing matters: oil mist capture, hot or corrosive exhaust, or simple per-station diagnostics. Otherwise the sizing logic is the same - Cv 0.1 per station, so move a flow-hungry point to an individual 3V2 (Cv 0.18 at 1/8 in, 0.19 at 1/4 in, vacuum-rated) or a 3V3 (Cv 0.62 at 1/4 in), and use 3V1 at 3.0 W DC where power is tight.
Lock in five parameters when ordering: NC state, DC24V, DIN plug entry, 8 stations, independent exhaust. The initial state is fixed for the life of the valve and cannot be converted in the field. Double-acting cylinders are outside 3/2 scope - specify the AirTAC 4V series.
Confirm before you order
Eight NC 3/2 direct-acting poppet valves, DIN plug DC24V coils, on an 8-station base with independent exhaust. Cv 0.1 per station, 0-0.8 MPa (0-114 psi), -20 to 70 C, 7.0 W per coil, IP65 (DIN 40050), PT1/8 ports. Air filtered to 40 um or finer; lubrication not required.
Choose independent (D) when discharge must be piped, silenced or captured per station, or when you want to trace a faulty valve by its own exhaust. Choose centralised for one shared port and fewer fittings. Either way the NC initial state is fixed at purchase and cannot be swapped later.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.