The AirTAC Airtac 3V2M Solenoid Valve 3V2MNCC-15F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
Fifteen NC 3/2 valves, one base: the 3V2MNCC-15F is supplied as a complete AC110V assembly with DIN-plug coils, centralised exhaust and PT1/8 threads, ready to drop into a control panel or machine frame. Every valve is a direct-acting, spring-return poppet; outlets vent automatically whenever the coil is off.
Wiring fifteen points becomes one connector exercise, and plumbing becomes one supply run, because the dedicated base carries both. Fifteen coils at 7 VA each add up to 105 VA with all stations energised, inside IP65-protected housings. Flow per station is Cv 0.1. Order the state you need up front: NC and NO are set at the factory and cannot be swapped later.
| Model | Airtac 3V2M Solenoid Valve 3V2MNCC-15F |
|---|---|
| Series | 3V2M |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Initial state | Normally closed |
| Item form | Complete assembly — 15 valves on a shared base |
| Exhaust | Centralised exhaust |
| Port size | 1/8 in |
| Thread | PT |
| Coil voltage | AC110V |
|---|---|
| Electrical entry | DIN plug (DIN socket type) |
| Coil power | 7 VA |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Not rated for vacuum |
| Flow coefficient | Cv 0.1 |
| Temperature | -20 to 70 C |
| Construction | Coaxial shut-off (poppet), base-mounted, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V2M catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V2M | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| 1/8 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| NC | Normally closed: no air at the outlet until the coil is energised. |
| AC110V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| — | Electrical entry: I = flying lead, otherwise a DIN plug. |
| 15F | 15 stations in one assembly, centralised exhaust. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
Spring-return grippers on a palletising head hold boxes only while energised; fifteen NC valves share one air feed and one plug.
Sample drawers and sealing jaws in a diagnostic analyser open on spring return, switched by NC valves on a compact manifold.
Injection tool core pins retract by spring when de-energised, sequenced from a 15-station base with centralised exhaust.
Choose this manifold when wiring and plumbing time matters more than per-station flow: each valve is Cv 0.1, lower than the individually ported 3V2 (Cv 0.18 at 1/8 in, 0.19 at 1/4 in, vacuum-rated) and far below the 3V3 at Cv 0.62 (1/4 in, vacuum-rated). Light, low-power duties can use 3V1 bodies at just 3.0 W DC. Double-acting cylinders are out of scope for any 3-port valve - that is a job for the 5-port AirTAC 4V series. Before ordering, fix five things: NC or NO (no conversion afterwards), AC110V coil, DIN plug or flying lead, 15 stations, centralised or independent exhaust, and thread (PT standard, G and NPT to order).
Confirm before you order
Every station: 3/2 NC poppet valve, Cv 0.1, 0-0.8 MPa operating pressure, -20 to 70 C media temperature, 7 VA AC coil (AC110V here), IP65 housing. Fifteen energised coils draw up to 105 VA. Thread is PT1/8 as standard; G and NPT are catalogue options.
This 15-station assembly uses centralised exhaust: all stations vent through one shared port, which keeps piping short. If a process needs to capture or route each station's spent air separately, order the same valves with D (independent exhaust) in the code instead.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.