The AirTAC Airtac 3V2M Solenoid Valve 3V2MNCC-17F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
The AirTAC 3V2MNCC-17F is a complete 17-station manifold assembly: seventeen normally closed 3/2 valve bodies fixed to a matching 17F base. Each body is direct-acting with a single solenoid and spring return, built around a coaxial poppet shut-off that seats firmly on PT1/8 ports. Normally closed means no air reaches any outlet until that coil is energised.
Because every valve sits on one base, all seventeen share a single air supply and a single wiring run, so a fault shows up station by station instead of across seventeen loose valves. Coils are AC110V at 7 VA each through DIN plugs - budget up to 119 VA if all seventeen hold energised at once. Exhausts join into one centralised port, and Cv 0.1 per station is a flow coefficient set by the base path, not a flow rate.
| Model | Airtac 3V2M Solenoid Valve 3V2MNCC-17F |
|---|---|
| Series | 3V2M |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Initial state | Normally closed |
| Item form | Complete assembly — 17 valves on a shared base |
| Exhaust | Centralised exhaust |
| Port size | 1/8 in |
| Thread | PT |
| Coil voltage | AC110V |
|---|---|
| Electrical entry | DIN plug (DIN socket type) |
| Coil power | 7 VA |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Not rated for vacuum |
| Flow coefficient | Cv 0.1 |
| Temperature | -20 to 70 C |
| Construction | Coaxial shut-off (poppet), base-mounted, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V2M catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V2M | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| 1/8 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| NC | Normally closed: no air at the outlet until the coil is energised. |
| AC110V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| — | Electrical entry: I = flying lead, otherwise a DIN plug. |
| 17F | 17 stations in one assembly, centralised exhaust. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
Seventeen single-acting swing clamps on a car-body jig toggled in sequence from one AC110V rail and one air inlet.
Per-lane cap chute gates and reject blow-off nozzles switched individually, all venting into one centralised exhaust.
Seventeen pneumatic hold-downs on a stamping die that stay vented and safe whenever power is lost, thanks to the normally closed state.
Pick 3V2M when manifold density matters more than per-station flow: Cv 0.1 per station, because the flow path runs through the base. If one station needs a bigger flow path, mount an individual 3V2 there instead (Cv 0.18 at 1/8 in, 0.19 at 1/4 in, and vacuum-rated); for the highest flow in the range, 3V3 gives Cv 0.62 at 1/4 in and is also vacuum-rated; for a small duty, 3V1 runs at just 3.0 W on DC. Double-acting cylinders are outside any 3/2 valve - that takes the AirTAC 4V series. Confirm the state before ordering: normally closed cannot be converted to normally open after purchase, by any means.
Match five points plus thread: initial state NC, coil AC110V, entry DIN plug, 17 stations, centralised exhaust, and PT thread - the standard on this family, with G and NPT as order options.
Confirm before you order
It is a 3/2-way normally closed manifold assembly with Cv 0.1 per station, operating pressure 0-0.8 MPa (0-114 psi), media temperature -20 to 70 C, AC110V coil power 7 VA (DC versions 7.0 W), IP65 protection (DIN 40050), PT1/8 ports and centralised exhaust.
No. The state is fixed by how the valve is built; the dedicated base gasket cannot be flipped to convert NC to NO, and the catalogue states this explicitly. Order 3V2MNOCC-17F instead if your logic needs normally open.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.