The AirTAC Airtac 3V2M Solenoid Valve 3V2MNCC-4F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
The 3V2MNCC-4F is a ready-matched set of four 3V2M normally closed valve bodies on one 4-station base. Each body is a direct-acting, single-solenoid 3/2 unit with spring return and a coaxial poppet that seals positively, so a de-energised station keeps its outlet vented until the AC110V coil is switched. Port size is PT1/8 and the flow coefficient is Cv 0.1.
Because all four valves share one supply gallery and one wiring run on the base, commissioning and fault-finding stay simple: a single air connection feeds every station and one DIN plug per coil carries the 110 V AC signal. The gasket that seats each valve on its base is dedicated, so a normally closed unit cannot be converted to normally open by flipping it - order the state you need.
| Model | Airtac 3V2M Solenoid Valve 3V2MNCC-4F |
|---|---|
| Series | 3V2M |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Initial state | Normally closed |
| Item form | Complete assembly — 4 valves on a shared base |
| Exhaust | Centralised exhaust |
| Port size | 1/8 in |
| Thread | PT |
| Coil voltage | AC110V |
|---|---|
| Electrical entry | DIN plug (DIN socket type) |
| Coil power | 7 VA |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Not rated for vacuum |
| Flow coefficient | Cv 0.1 |
| Temperature | -20 to 70 C |
| Construction | Coaxial shut-off (poppet), base-mounted, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V2M catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V2M | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| 1/8 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| NC | Normally closed: no air at the outlet until the coil is energised. |
| AC110V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| — | Electrical entry: I = flying lead, otherwise a DIN plug. |
| 4F | 4 stations in one assembly, centralised exhaust. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
Four spring-return clamps on a rotary indexing table are controlled one per station, each staying vented until its AC110V coil is energised.
Downstream of a checkweigher, the reject flap cylinder vents whenever the line stops, holding the gate in its safe home position.
A four-part fastening jig uses one valve per clamp, all fed from a single PT1/8 supply line on the shared base.
Match five points before ordering: initial state (NC here), coil voltage (AC110V), electrical entry (DIN plug), station count (4) and exhaust type (centralised), plus thread - PT is standard on this family and G or NPT are catalogue options to order. NC means no air at any outlet until its coil is energised, and that state is fixed for life of the unit.
3V2M is the manifold-density pick at Cv 0.1. If one station needs more flow, run an individual 3V2 there (Cv 0.18 at 1/8 in, 0.19 at 1/4 in, and vacuum rated) or a 3V3 (Cv 0.62 at 1/4 in, also vacuum rated). Where the duty is light and power is tight, the 3V1 body draws only 3.0 W on DC. A 3/2 valve drives single-acting cylinders, blow and pilot duty - for double-acting cylinders specify the AirTAC 4V series.
Confirm before you order
Each valve is 3/2, direct-acting, single solenoid with spring return, Cv 0.1, operating pressure 0-0.8 MPa (0-114 psi), temperature -20 to 70 C, AC110V coil at 7 VA, IP65 to DIN 40050, PT1/8 port, air filtered to 40 um or finer. Four normally closed stations share one base with centralised exhaust.
No. The 3V2M base gasket is dedicated and flipping it does not change the initial state; NC or NO is fixed by the valve you order. If outlets must pass air before energising, order the NO version. Also note a 3/2 valve drives single-acting cylinders only - double-acting needs the AirTAC 4V series.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.