The AirTAC Airtac 3V2M Solenoid Valve 3V2MNCC-8F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
3V2MNCC-8F is a complete AirTAC 3V2M assembly: eight normally closed valve bodies on one dedicated 8-station base with centralised exhaust. Each valve is a direct-acting 3/2 poppet unit with spring return, an AC110V coil and DIN plug entry, so a de-energised station holds its outlet vented until the solenoid is switched. Because the coils share one wiring run across the manifold, a stuck station can be isolated quickly without tracing eight separate harnesses.
Power planning is simple arithmetic: every AC coil draws 7 VA, so eight stations energised together present roughly 56 VA to your control transformer. Flow through the base is Cv 0.1 per valve, which suits pilot and small single-acting loads rather than high-volume blow. Protection is IP65 (DIN 40050) and each valve carries a manual override for commissioning. Note that NC cannot be converted to NO in the field - the dedicated base gasket cannot be reversed to change state.
| Model | Airtac 3V2M Solenoid Valve 3V2MNCC-8F |
|---|---|
| Series | 3V2M |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Initial state | Normally closed |
| Item form | Complete assembly — 8 valves on a shared base |
| Exhaust | Centralised exhaust |
| Port size | 1/8 in |
| Thread | PT |
| Coil voltage | AC110V |
|---|---|
| Electrical entry | DIN plug (DIN socket type) |
| Coil power | 7 VA |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Not rated for vacuum |
| Flow coefficient | Cv 0.1 |
| Temperature | -20 to 70 C |
| Construction | Coaxial shut-off (poppet), base-mounted, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V2M catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V2M | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| 1/8 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| NC | Normally closed: no air at the outlet until the coil is energised. |
| AC110V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| — | Electrical entry: I = flying lead, otherwise a DIN plug. |
| 8F | 8 stations in one assembly, centralised exhaust. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
Eight spring-return clamping cylinders on a machining fixture sequence from one supply; each NC valve vents its clamp until told to fire, so a power loss leaves the table unclamped and safe to approach.
A parcel sorter with eight divert gates runs one valve per gate; the shared wiring run means a dead gate shows up as one missing solenoid, not a hunt through eight looms.
Independent on/off air to eight paint spray nozzles; Cv 0.1 keeps the duty within pilot range while the centralised exhaust pipe carries all vented air to one filter.
Match five points before ordering: initial state (NC here, fixed at purchase), coil voltage (AC110V), electrical entry (DIN plug), station count (8) and exhaust type (centralised), with PT as the standard thread and G or NPT available to order. 3V2M trades flow for manifold density at Cv 0.1; if one station needs more, run an individual 3V2 (Cv 0.18 at 1/8, 0.19 at 1/4) or a 3V3 (Cv 0.62, 1/4) on that function instead. For low-power duty elsewhere in the panel, 3V1 runs at 3.0 W DC. A double-acting cylinder needs a 5-port AirTAC 4V valve, not this 3/2 series.
Confirm before you order
Each 3/2 valve is Cv 0.1, rated 0-0.8 MPa (0-114 psi) and -20 to 70 C; the AC110V coil draws 7 VA per station and the body is IP65 (DIN 40050). The assembly uses PT1/8 ports, with G and NPT as order options.
No. The initial state is fixed when ordered, and the dedicated 3V2M base gasket cannot be reversed to swap it. Order the exact state per station; mixed states across stations are allowed, since stations combine and expand freely.