Airtac 3V2M Solenoid Valve 3V2MNCCI-2F

The AirTAC Airtac 3V2M Solenoid Valve 3V2MNCCI-2F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.

  • Valve type3/2-way (3-port, 2-position)
  • Initial stateNormally closed
  • Port size1/8 in
  • Coil voltageAC110V
  • Electrical entryFlying lead (lead-out wire type)
  • Stations2
  • Flow (Cv)0.1
  • Series3V2M
$90.40 $96.33Save 6% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every 3V2M manifold set voltage, station and exhaust option on one page All 3V2M manifold set codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac 3V2M Solenoid Valve 3V2MNCCI-2F

Two 3V2M NC valve bodies are factory-matched to a 2-station base in this complete 3V2MNCCI-2F assembly. Each valve is a direct-acting, single-solenoid 3/2 unit with spring return and a coaxial shut-off poppet for good sealing. Because the initial state is NC, no air reaches any outlet until that coil is energised - the supply line sits live but every circuit stays vented. The C voltage code runs each coil on AC110V at 7 VA.

The I entry gives each station a pre-wired flying lead instead of a DIN socket, which speeds up wiring in tight control panels. Both valves draw supply and wiring from the shared base, so a fault on one circuit is traced without disturbing the other. Coil housings are IP65 to DIN 40050, and a manual override on each body helps during installation and commissioning.

Airtac 3V2M Solenoid Valve 3V2MNCCI-2F Technical Specifications

ModelAirtac 3V2M Solenoid Valve 3V2MNCCI-2F
Series3V2M
Valve type3/2-way (3-port, 2-position)
FunctionDirect-acting, single solenoid, spring return
Initial stateNormally closed
Item formComplete assembly — 2 valves on a shared base
ExhaustCentralised exhaust
Port size1/8 in
ThreadPT
Coil voltageAC110V
Electrical entryFlying lead (lead-out wire type)
Coil power7 VA
Operating pressure0-0.8 MPa (0-114 psi)
Vacuum serviceNot rated for vacuum
Flow coefficientCv 0.1
Temperature-20 to 70 C
ConstructionCoaxial shut-off (poppet), base-mounted, spring return
ProtectionIP65 (DIN 40050)
MediumAir, filtered by a 40 µm or finer element. Lubrication not required.

Figures follow the official AirTAC 3V2M catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

The initial state cannot be changed after ordering. 3V2M uses a dedicated base gasket, and reversing or flipping that gasket does not convert NC to NO. Order the state you need up front.

Model Code: Airtac 3V2M Solenoid Valve 3V2MNCCI-2F

3V2MBody — sets the flow, the coil power and whether vacuum is rated.
1/8 inPort size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in.
NCNormally closed: no air at the outlet until the coil is energised.
AC110VCoil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V.
IElectrical entry: I = flying lead, otherwise a DIN plug.
2F2 stations in one assembly, centralised exhaust.
PTPort thread. PT ships from stock; G and NPT are available to order.

What a 3/2 Valve Does

A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.

That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.

It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.

Where the Airtac 3V2M Solenoid Valve 3V2MNCCI-2F Is Used

view_module

Carton flap folders

A small case-sealing machine with two spring-return flap-fold cylinders: one NC station per folder, sequenced from a single supply, each outlet staying vented until its turn comes.

bolt

Fixture clamp pair

Two swing clamps on a machining fixture share the base supply and wiring, so a stuck clamp is diagnosed at the manifold instead of tracing individual valve connections.

conveyor_belt

Conveyor divert gate

Sorting lines use one station for the gate pusher and one for a product stop, both spring-return, both safely vented whenever the machine is de-energised.

Is the Airtac 3V2M Solenoid Valve 3V2MNCCI-2F the Right Part?

Order the state deliberately: NC on this assembly cannot be converted to NO afterwards - flipping or reversing the dedicated base gasket does not change the function. Match five points before buying: initial state, coil voltage (here AC110V), electrical entry (flying lead), station count (2) and exhaust routing (centralised, so both stations vent through one port). Thread is PT1/8 as standard on this family; G and NPT are catalogue options to order.

At Cv 0.1 per station, 3V2M trades flow for manifold density because the flow path runs through the base. If one circuit needs more flow, an individual 3V2 gives Cv 0.18 at 1/8 in or 0.19 at 1/4 in and is vacuum-rated, while 3V3 reaches Cv 0.62 at 1/4 in for the highest flow in the 3V range. For low-duty, low-power points, 3V1 runs at just 3.0 W on DC. A double-acting cylinder needs a 5-port valve from the AirTAC 4V series, not this 3/2 valve.

Confirm before you order

  • ✓ Port size and thread (PT from stock; G / NPT to order)
  • ✓ Initial state — NC or NO, ordered up front
  • ✓ Coil voltage matches your controller output
  • ✓ Electrical entry — DIN plug or flying lead
  • ✓ Single valve, bare base, or complete assembly
  • ✓ Single-acting duty, not double-acting
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Stay within 0-0.8 MPa (0-114 psi) operating pressure.
  • check Match the coil voltage to your controller output.
  • check Use the manual override to test before powering up.
  • check Leave the exhaust port clear, or fit a silencer.
  • check Blank any unused station on the base before pressurising.
  • check Wiring by qualified personnel, per AirTAC documentation.

Airtac 3V2M Solenoid Valve 3V2MNCCI-2F FAQ

Each 3/2 valve has a flow coefficient Cv 0.1, operates at 0-0.8 MPa between -20 and 70 C, and its AC110V coil draws 7 VA. The coil housing is rated IP65 (DIN 40050). Ports are PT1/8 and the base exhausts centrally.

The initial state is fixed by the valve variant. 3V2M uses a dedicated base gasket, and reversing that gasket does not convert NC to NO - there is no field conversion of any kind. If your circuits should pass air when de-energised, order the NO equivalent, 3V2MNOCI-2F, instead.

verified

Authorized Export Seller

Genuine AirTAC parts produced by the AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac 3V2M Solenoid Valve 3V2MNCCI-2F

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 3V2MNCCI-2F and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.