AirTAC 3V2M · 3/2-Way Solenoid Valve

Airtac 3V2M Solenoid Valve 3V2MNCE

The AirTAC Airtac 3V2M Solenoid Valve 3V2MNCE is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.

  • Valve type3/2-way (3-port, 2-position)
  • Initial stateNormally closed
  • Port size1/8 in
  • Coil voltageAC24V
  • Electrical entryDIN plug (DIN socket type)
  • Flow (Cv)0.1
  • Series3V2M
$43.43 $48.20Save 9% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every 3V2M valve body type, voltage and entry option on one page All 3V2M valve body codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac 3V2M Solenoid Valve 3V2MNCE

3V2MNCE is the normally closed valve body of the AirTAC 3V2M manifold family. With no power on its AC24V coil the outlet stays shut and the downstream line vents; energise the DIN-plug coil and air flows to the actuator. It is direct acting with a single solenoid and spring return, built as a coaxial poppet shut-off so the seat seals positively at Cv 0.1.

The body is not piped directly - it seats onto a dedicated 3V2M base block, where it shares one air supply and one wiring loom with its neighbours. IP65 (DIN 40050) protects the coil connection in dirty electrical cabinets, and a manual override on the body helps prove the circuit during setup. Order the state you need up front: NC cannot be converted to NO after purchase.

Airtac 3V2M Solenoid Valve 3V2MNCE Technical Specifications

ModelAirtac 3V2M Solenoid Valve 3V2MNCE
Series3V2M
Valve type3/2-way (3-port, 2-position)
FunctionDirect-acting, single solenoid, spring return
Initial stateNormally closed
Port size1/8 in
ThreadPT
Coil voltageAC24V
Electrical entryDIN plug (DIN socket type)
Coil power7 VA
Operating pressure0-0.8 MPa (0-114 psi)
Vacuum serviceNot rated for vacuum
Flow coefficientCv 0.1
Temperature-20 to 70 C
ConstructionCoaxial shut-off (poppet), base-mounted, spring return
ProtectionIP65 (DIN 40050)
MediumAir, filtered by a 40 µm or finer element. Lubrication not required.

Figures follow the official AirTAC 3V2M catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

The initial state cannot be changed after ordering. 3V2M uses a dedicated base gasket, and reversing or flipping that gasket does not convert NC to NO. Order the state you need up front.

Model Code: Airtac 3V2M Solenoid Valve 3V2MNCE

3V2MBody — sets the flow, the coil power and whether vacuum is rated.
1/8 inPort size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in.
NCNormally closed: no air at the outlet until the coil is energised.
AC24VCoil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V.
—Electrical entry: I = flying lead, otherwise a DIN plug.
PTPort thread. PT ships from stock; G and NPT are available to order.

What a 3/2 Valve Does

A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.

That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.

It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.

Where the Airtac 3V2M Solenoid Valve 3V2MNCE Is Used

precision_manufacturing

Indexing dial clamp control

One 3V2MNCE per clamp position on a rotary indexing table vents each spring-return clamp when de-energised, so a control fault cannot leave a clamp holding.

speed

Stamping pilot valve duty

High-cycle press pilots suit a direct-acting poppet: the AC24V coil at 7 VA is a light load on the control transformer and the spring return resets the flow path every stroke.

handyman

Spares for 3V2M panels

Keep this body as a spare for existing 3V2M bases: it seats straight onto the shared supply and shared wiring, and the manual override helps verify the circuit during a swap.

Is the Airtac 3V2M Solenoid Valve 3V2MNCE the Right Part?

Buy this body when you are populating or replacing one station on a 3V2M base. Match five points: initial state NC, coil voltage AC24V, electrical entry DIN plug, and the thread on your base - PT is the standard thread on this family, with G and NPT as order options. The state is fixed: a flipped base gasket does not turn NC into NO, so order NC deliberately.

If the station needs more flow than Cv 0.1 gives, use a piped 3V2 (Cv 0.18 at 1/8, 0.19 at 1/4, vacuum-rated) or 3V3 (Cv 0.62, 1/4, vacuum-rated); if the duty is light, 3V1 saves power at 3.0 W DC. Driving a double-acting cylinder needs a 5-port AirTAC 4V instead.

Confirm before you order

  • ✓ Port size and thread (PT from stock; G / NPT to order)
  • ✓ Initial state — NC or NO, ordered up front
  • ✓ Coil voltage matches your controller output
  • ✓ Electrical entry — DIN plug or flying lead
  • ✓ Single valve, bare base, or complete assembly
  • ✓ Single-acting duty, not double-acting
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Stay within 0-0.8 MPa (0-114 psi) operating pressure.
  • check Match the coil voltage to your controller output.
  • check Use the manual override to test before powering up.
  • check Leave the exhaust port clear, or fit a silencer.
  • check Wiring by qualified personnel, per AirTAC documentation.

Airtac 3V2M Solenoid Valve 3V2MNCE FAQ

It is a 3/2 direct-acting poppet valve, normally closed, Cv 0.1, operating pressure 0-0.8 MPa (0-114 psi), temperature -20 to 70 C, AC coil power 7 VA, IP65 (DIN 40050), PT1/8 port, with G and NPT as order options. It needs no lubricated air, only filtration to 40 um or finer.

No. The initial state is chosen when ordering and cannot be converted afterwards - AirTAC notes that reversing the dedicated base gasket does not switch NC to NO. If a circuit must pass air until energised, order that station as a NO body from the start.

verified

Authorized Export Seller

Genuine AirTAC parts produced by the AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac 3V2M Solenoid Valve 3V2MNCE

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 3V2MNCE and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.