verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC 3V2M · Valve Manifold Assembly

Airtac 3V2M Solenoid Valve 3V2MNCE-13F

The AirTAC Airtac 3V2M Solenoid Valve 3V2MNCE-13F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.

  • Valve type3/2-way (3-port, 2-position)
  • Initial stateNormally closed
  • Port size1/8 in
  • Coil voltageAC24V
  • Electrical entryDIN plug (DIN socket type)
  • Stations13
  • Flow (Cv)0.1
  • Series3V2M
$532.41 $549.30Save 3% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every 3V2M manifold set voltage, station and exhaust option on one page All 3V2M manifold set codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac 3V2M Solenoid Valve 3V2MNCE-13F

The 3V2MNCE-13F is a ready-matched 13-station bank: thirteen NC 3/2 valve bodies seated on one dedicated 3V2M base, every coil wound for AC24V and terminated as a DIN plug. Each body is direct-acting with a single solenoid and spring return, built as a coaxial shut-off poppet so sealing stays positive across millions of cycles. Thirteen outlets stay vented until their coils are energised.

Running the bank at 24 V AC keeps the control circuit at a safety extra-low voltage, which suits machines where operators work close to live solenoid panels. Budget the transformer for the worst case: 13 coils at 7 VA each is 91 VA if every station energises together. A manual override on each body helps you prove out the fixture before wiring is final.

Airtac 3V2M Solenoid Valve 3V2MNCE-13F Technical Specifications

ModelAirtac 3V2M Solenoid Valve 3V2MNCE-13F
Series3V2M
Valve type3/2-way (3-port, 2-position)
FunctionDirect-acting, single solenoid, spring return
Initial stateNormally closed
Item formComplete assembly — 13 valves on a shared base
ExhaustCentralised exhaust
Port size1/8 in
ThreadPT
Coil voltageAC24V
Electrical entryDIN plug (DIN socket type)
Coil power7 VA
Operating pressure0-0.8 MPa (0-114 psi)
Vacuum serviceNot rated for vacuum
Flow coefficientCv 0.1
Temperature-20 to 70 C
ConstructionCoaxial shut-off (poppet), base-mounted, spring return
ProtectionIP65 (DIN 40050)
MediumAir, filtered by a 40 µm or finer element. Lubrication not required.

Figures follow the official AirTAC 3V2M catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

The initial state cannot be changed after ordering. 3V2M uses a dedicated base gasket, and reversing or flipping that gasket does not convert NC to NO. Order the state you need up front.

Model Code: Airtac 3V2M Solenoid Valve 3V2MNCE-13F

3V2MBody — sets the flow, the coil power and whether vacuum is rated.
1/8 inPort size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in.
NCNormally closed: no air at the outlet until the coil is energised.
AC24VCoil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V.
—Electrical entry: I = flying lead, otherwise a DIN plug.
13F13 stations in one assembly, centralised exhaust.
PTPort thread. PT ships from stock; G and NPT are available to order.

What a 3/2 Valve Does

A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.

That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.

It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.

Where the Airtac 3V2M Solenoid Valve 3V2MNCE-13F Is Used

precision_manufacturing

Indexing dial clamp banks

Thirteen NC outlets suit a rotary indexing machine where workholding clamps on each dial position must vent the moment their station de-energises.

view_module

Sorter gate flappers

A parcel sorter with thirteen divert stations can drive one gate per slot from this bank, all fed and wired from a single supply run.

science

Leak-test port switching

A quality lab bench switching thirteen test ports one at a time gains from shared wiring, with each NC port vented by default between tests.

Is the Airtac 3V2M Solenoid Valve 3V2MNCE-13F the Right Part?

Order the initial state deliberately: the dedicated base gasket on 3V2M does not convert NC to NO when flipped, and there is no field conversion of any kind - NC stays NC for life. Before buying, confirm five points: NC state, AC24V coil, DIN plug entry, 13 stations, centralised exhaust, plus thread (PT standard on this family; G and NPT are catalogue options to order).

Flow is the trade-off for density: Cv 0.1 through the base. If one station needs more air, run an individual 3V2 (Cv 0.18 at 1/8 inch, 0.19 at 1/4 inch, vacuum-rated) or a 3V3 (Cv 0.62, 1/4 inch, vacuum-rated); pick 3V1 at 3.0 W DC where duty is light and coil heat matters. These valves drive single-acting spring-return cylinders only - for a double-acting cylinder you need a 5-port 4V series valve.

Confirm before you order

  • ✓ Port size and thread (PT from stock; G / NPT to order)
  • ✓ Initial state — NC or NO, ordered up front
  • ✓ Coil voltage matches your controller output
  • ✓ Electrical entry — DIN plug or flying lead
  • ✓ Single valve, bare base, or complete assembly
  • ✓ Single-acting duty, not double-acting
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Stay within 0-0.8 MPa (0-114 psi) operating pressure.
  • check Match the coil voltage to your controller output.
  • check Use the manual override to test before powering up.
  • check Leave the exhaust port clear, or fit a silencer.
  • check Blank any unused station on the base before pressurising.
  • check Wiring by qualified personnel, per AirTAC documentation.

Airtac 3V2M Solenoid Valve 3V2MNCE-13F FAQ

It is a 13-station assembly of NC 3/2 valves: Cv 0.1 flow coefficient, operating pressure 0-0.8 MPa, media temperature -20 to 70 C, AC coils at 7 VA each (DC versions are 7.0 W), IP65 to DIN 40050, PT1/8 port on a PT-thread base (G and NPT to order), air filtered to 40 um or finer.

No. 3V2M uses a dedicated base gasket and flipping that gasket does not change the state; the manufacturer states the initial state is fixed at order time. If any station must pass air while de-energised, order that station as an NO valve in the same bank.

verified

Authorized Export Seller

Genuine AirTAC parts produced by the AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac 3V2M Solenoid Valve 3V2MNCE-13F

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 3V2MNCE-13F and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.