The AirTAC Airtac 3V2M Solenoid Valve 3V2MNCE-14F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.

  • Valve type3/2-way (3-port, 2-position)
  • Initial stateNormally closed
  • Port size1/8 in
  • Coil voltageAC24V
  • Electrical entryDIN plug (DIN socket type)
  • Stations14
  • Flow (Cv)0.1
  • Series3V2M
$572.57 $590.46Save 3% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every 3V2M manifold set voltage, station and exhaust option on one page All 3V2M manifold set codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac 3V2M Solenoid Valve 3V2MNCE-14F

Fourteen NC 3/2 valve bodies, all AC24V with DIN plug connection, sit on one machined 3V2M base in the 3V2MNCE-14F. Every valve is a direct-acting, spring-return, coaxial poppet unit, so a de-energised station holds its outlet vented and only feeds air when its solenoid pulls in.

The maintenance win is diagnostic: one air feed and one wiring loom serve all fourteen stations, so a stuck output is isolated in minutes without tracing fourteen separate feeds. Exhaust air from all stations merges and leaves through a single centralised port. Coils are rated IP65 (DIN 40050), and each body carries a manual override for commissioning checks.

Airtac 3V2M Solenoid Valve 3V2MNCE-14F Technical Specifications

ModelAirtac 3V2M Solenoid Valve 3V2MNCE-14F
Series3V2M
Valve type3/2-way (3-port, 2-position)
FunctionDirect-acting, single solenoid, spring return
Initial stateNormally closed
Item formComplete assembly — 14 valves on a shared base
ExhaustCentralised exhaust
Port size1/8 in
ThreadPT
Coil voltageAC24V
Electrical entryDIN plug (DIN socket type)
Coil power7 VA
Operating pressure0-0.8 MPa (0-114 psi)
Vacuum serviceNot rated for vacuum
Flow coefficientCv 0.1
Temperature-20 to 70 C
ConstructionCoaxial shut-off (poppet), base-mounted, spring return
ProtectionIP65 (DIN 40050)
MediumAir, filtered by a 40 µm or finer element. Lubrication not required.

Figures follow the official AirTAC 3V2M catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

The initial state cannot be changed after ordering. 3V2M uses a dedicated base gasket, and reversing or flipping that gasket does not convert NC to NO. Order the state you need up front.

Model Code: Airtac 3V2M Solenoid Valve 3V2MNCE-14F

3V2MBody — sets the flow, the coil power and whether vacuum is rated.
1/8 inPort size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in.
NCNormally closed: no air at the outlet until the coil is energised.
AC24VCoil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V.
—Electrical entry: I = flying lead, otherwise a DIN plug.
14F14 stations in one assembly, centralised exhaust.
PTPort thread. PT ships from stock; G and NPT are available to order.

What a 3/2 Valve Does

A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.

That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.

It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.

Where the Airtac 3V2M Solenoid Valve 3V2MNCE-14F Is Used

conveyor_belt

Bottle ejection on a filler

Fourteen eject fingers along a bottling conveyor can each kick a defective bottle off the line, all fed from one shared supply leg.

build

Welding fixture clamp array

A car-body welding fixture with fourteen pneumatic swing clamps vents every clamp the instant its AC24V coil drops out, a fail-safe NC pattern.

settings_input_component

Pick-and-place gripper bank

A gantry picker handling fourteen suction-part stations uses one NC valve per cup station, simplifying the loom to a single shared feed.

Is the Airtac 3V2M Solenoid Valve 3V2MNCE-14F the Right Part?

Fix the configuration before ordering - NC and NO are locked in at purchase because the dedicated base gasket cannot be reversed to swap state. Match five points to your machine: initial state NC, coil AC24V, electrical entry DIN plug, 14 stations, centralised exhaust, and thread (PT is the family standard; G and NPT are order options).

At Cv 0.1 the manifold favours many small duties over one hungry actuator. A station needing more flow should move to an individual 3V2 (Cv 0.18 at 1/8 inch, 0.19 at 1/4 inch, vacuum-rated) or 3V3 (Cv 0.62, 1/4 inch, vacuum-rated); 3V1 at 3.0 W DC covers low-power duty. Single-acting cylinders and blow duty are the fit here; double-acting cylinders require the 5-port AirTAC 4V series.

Confirm before you order

  • ✓ Port size and thread (PT from stock; G / NPT to order)
  • ✓ Initial state — NC or NO, ordered up front
  • ✓ Coil voltage matches your controller output
  • ✓ Electrical entry — DIN plug or flying lead
  • ✓ Single valve, bare base, or complete assembly
  • ✓ Single-acting duty, not double-acting
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Stay within 0-0.8 MPa (0-114 psi) operating pressure.
  • check Match the coil voltage to your controller output.
  • check Use the manual override to test before powering up.
  • check Leave the exhaust port clear, or fit a silencer.
  • check Blank any unused station on the base before pressurising.
  • check Wiring by qualified personnel, per AirTAC documentation.

Airtac 3V2M Solenoid Valve 3V2MNCE-14F FAQ

14 stations of NC 3/2 valves on one base: Cv 0.1, pressure range 0-0.8 MPa, temperature -20 to 70 C, AC24V coils at 7 VA each (DC builds are 7.0 W), protection IP65 (DIN 40050), PT1/8 port, PT base thread standard with G and NPT orderable, air filtered 40 um or better.

This assembly routes all fourteen stations into one centralised exhaust, so you fit and silence a single muffler instead of fourteen, and duct one discharge point out of the machine. If individual stations must vent to separate locations instead, order the D independent-exhaust variant of the base.

verified

Authorized Export Seller

Genuine AirTAC parts produced by the AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac 3V2M Solenoid Valve 3V2MNCE-14F

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 3V2MNCE-14F and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.