verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC 3V2M · Valve Manifold Assembly

Airtac 3V2M Solenoid Valve 3V2MNCEI-4F

The AirTAC Airtac 3V2M Solenoid Valve 3V2MNCEI-4F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.

  • Valve type3/2-way (3-port, 2-position)
  • Initial stateNormally closed
  • Port size1/8 in
  • Coil voltageAC24V
  • Electrical entryFlying lead (lead-out wire type)
  • Stations4
  • Flow (Cv)0.1
  • Series3V2M
$170.76 $178.68Save 4% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every 3V2M manifold set voltage, station and exhaust option on one page All 3V2M manifold set codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac 3V2M Solenoid Valve 3V2MNCEI-4F

The 3V2MNCEI-4F is a complete four-station manifold: four 3/2 NC valve bodies pre-mounted on a shared 3V2M base. Normally closed means each outlet stays vented and passes no air until its coil is energised, so a de-energised machine is a safe machine on this bank. Every valve is direct acting with a single solenoid and spring return, built around a coaxial poppet that shuts off cleanly.

Because the bodies sit on one dedicated base, the whole bank draws from a single PT1/8 supply and one wiring run, and fault-finding moves station by station instead of valve by valve. Each AC110V coil takes 7 VA, so the fully energised worst case is 28 VA - size the control transformer for that. A manual override on every body helps you prove plumbing before power-up.

Airtac 3V2M Solenoid Valve 3V2MNCEI-4F Technical Specifications

ModelAirtac 3V2M Solenoid Valve 3V2MNCEI-4F
Series3V2M
Valve type3/2-way (3-port, 2-position)
FunctionDirect-acting, single solenoid, spring return
Initial stateNormally closed
Item formComplete assembly — 4 valves on a shared base
ExhaustCentralised exhaust
Port size1/8 in
ThreadPT
Coil voltageAC24V
Electrical entryFlying lead (lead-out wire type)
Coil power7 VA
Operating pressure0-0.8 MPa (0-114 psi)
Vacuum serviceNot rated for vacuum
Flow coefficientCv 0.1
Temperature-20 to 70 C
ConstructionCoaxial shut-off (poppet), base-mounted, spring return
ProtectionIP65 (DIN 40050)
MediumAir, filtered by a 40 µm or finer element. Lubrication not required.

Figures follow the official AirTAC 3V2M catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

The initial state cannot be changed after ordering. 3V2M uses a dedicated base gasket, and reversing or flipping that gasket does not convert NC to NO. Order the state you need up front.

Model Code: Airtac 3V2M Solenoid Valve 3V2MNCEI-4F

3V2MBody — sets the flow, the coil power and whether vacuum is rated.
1/8 inPort size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in.
NCNormally closed: no air at the outlet until the coil is energised.
AC24VCoil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V.
IElectrical entry: I = flying lead, otherwise a DIN plug.
4F4 stations in one assembly, centralised exhaust.
PTPort thread. PT ships from stock; G and NPT are available to order.

What a 3/2 Valve Does

A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.

That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.

It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.

Where the Airtac 3V2M Solenoid Valve 3V2MNCEI-4F Is Used

precision_manufacturing

Pick-and-place gripper bank

Four NC valves vent four suction or gripper circuits until commanded, so a dropped part cannot be held by a pressurised circuit after an E-stop.

view_module

Rotary indexing table clamps

Each station's clamp fixture gets its own 3/2 output from the shared base, keeping four clamp circuits on one supply and one wiring run.

science

Benchtop leak-test rig

Test chambers stay open to exhaust between cycles; energising the coil applies air only during the measured test window.

Is the Airtac 3V2M Solenoid Valve 3V2MNCEI-4F the Right Part?

This assembly is the density play: Cv 0.1 per valve keeps ports tight so four stations fit where individual valves would not. When one circuit needs more flow, fit an individual 3V2 instead (Cv 0.18 at 1/8 in, 0.19 at 1/4 in, and vacuum rated); step to 3V3 (Cv 0.62, 1/4 in) for the highest flow in the family, or to 3V1 at 3.0 W DC when coil draw matters most.

Confirm these points before ordering: NC initial state, AC110V coil, flying-lead entry, four stations, centralised exhaust, PT thread (G and NPT are catalogue options). The NC/NO choice is fixed at the factory - the dedicated base gasket cannot be reversed to convert the state later. Double-acting cylinders need the 5-port AirTAC 4V series, not this valve.

Confirm before you order

  • ✓ Port size and thread (PT from stock; G / NPT to order)
  • ✓ Initial state — NC or NO, ordered up front
  • ✓ Coil voltage matches your controller output
  • ✓ Electrical entry — DIN plug or flying lead
  • ✓ Single valve, bare base, or complete assembly
  • ✓ Single-acting duty, not double-acting
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Stay within 0-0.8 MPa (0-114 psi) operating pressure.
  • check Match the coil voltage to your controller output.
  • check Use the manual override to test before powering up.
  • check Leave the exhaust port clear, or fit a silencer.
  • check Blank any unused station on the base before pressurising.
  • check Wiring by qualified personnel, per AirTAC documentation.

Airtac 3V2M Solenoid Valve 3V2MNCEI-4F FAQ

Each valve: 3/2 normally closed, direct acting, spring return, Cv 0.1, PT1/8 port, operating pressure 0-0.8 MPa (0-114 psi), temperature -20 to 70 C, AC110V coil at 7 VA, protection IP65 (DIN 40050), manual override fitted. Air must be filtered to 40 um or finer; lubrication is not required.

No. The 3V2M NC and NO versions use a dedicated base gasket, and reversing that gasket does not convert the state. Initial state is set at order time, so specify NC or NO when you buy; if a circuit later needs NO action, order a 3V2MNO valve body for that station.

verified

Authorized Export Seller

Genuine AirTAC parts produced by the AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac 3V2M Solenoid Valve 3V2MNCEI-4F

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 3V2MNCEI-4F and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.