verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC 3V2M · Valve Manifold Assembly

Airtac 3V2M Solenoid Valve 3V2MNCF-15F

The AirTAC Airtac 3V2M Solenoid Valve 3V2MNCF-15F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.

  • Valve type3/2-way (3-port, 2-position)
  • Initial stateNormally closed
  • Port size1/8 in
  • Coil voltageDC12V
  • Electrical entryDIN plug (DIN socket type)
  • Stations15
  • Flow (Cv)0.1
  • Series3V2M
$612.77 $631.66Save 2% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every 3V2M manifold set voltage, station and exhaust option on one page All 3V2M manifold set codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac 3V2M Solenoid Valve 3V2MNCF-15F

The 3V2MNCF-15F is a factory-built 15-station assembly: fifteen 3V2M normally closed valve bodies mounted on one dedicated base, all fed from a shared air supply and shared wiring points. Each body is a 3/2 direct-acting unit with a single DC12V solenoid and spring return, sealed by a coaxial shut-off poppet for tight closing. Until a coil is energised, that station's outlet stays closed, so a de-energised actuator sees no air.

The base turns fifteen separate valves into one panel-friendly unit: air enters through a single inlet, wiring lands once instead of fifteen times, and faults can be traced station by station on the common manifold. Each DC coil draws 7.0 W and the bodies carry an IP65 (DIN 40050) rating. Note that the NC initial state is fixed at order stage - the dedicated base gasket cannot be flipped to convert NC to NO.

Airtac 3V2M Solenoid Valve 3V2MNCF-15F Technical Specifications

ModelAirtac 3V2M Solenoid Valve 3V2MNCF-15F
Series3V2M
Valve type3/2-way (3-port, 2-position)
FunctionDirect-acting, single solenoid, spring return
Initial stateNormally closed
Item formComplete assembly — 15 valves on a shared base
ExhaustCentralised exhaust
Port size1/8 in
ThreadPT
Coil voltageDC12V
Electrical entryDIN plug (DIN socket type)
Coil power7.0 W
Operating pressure0-0.8 MPa (0-114 psi)
Vacuum serviceNot rated for vacuum
Flow coefficientCv 0.1
Temperature-20 to 70 C
ConstructionCoaxial shut-off (poppet), base-mounted, spring return
ProtectionIP65 (DIN 40050)
MediumAir, filtered by a 40 µm or finer element. Lubrication not required.

Figures follow the official AirTAC 3V2M catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

The initial state cannot be changed after ordering. 3V2M uses a dedicated base gasket, and reversing or flipping that gasket does not convert NC to NO. Order the state you need up front.

Model Code: Airtac 3V2M Solenoid Valve 3V2MNCF-15F

3V2MBody — sets the flow, the coil power and whether vacuum is rated.
1/8 inPort size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in.
NCNormally closed: no air at the outlet until the coil is energised.
DC12VCoil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V.
—Electrical entry: I = flying lead, otherwise a DIN plug.
15F15 stations in one assembly, centralised exhaust.
PTPort thread. PT ships from stock; G and NPT are available to order.

What a 3/2 Valve Does

A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.

That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.

It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.

Where the Airtac 3V2M Solenoid Valve 3V2MNCF-15F Is Used

precision_manufacturing

Indexing dial clamps

Spring-return clamps on a 15-position rotary indexing table for small electronic parts: each NC valve feeds one clamp only while energised, and every clamp releases the moment its coil drops.

conveyor_belt

Parcel diverter gates

Sortation conveyors with one single-acting diverter gate per lane: fifteen gates share one supply inlet and one wiring point, so a jammed lane can be traced without opening a control cabinet.

science

Leak-test probe actuation

A leak-test bench pressing spring-return probes onto fifteen ports in turn; NC logic guarantees no probe sees air until the controller commands it.

Is the Airtac 3V2M Solenoid Valve 3V2MNCF-15F the Right Part?

Choose the 3V2M manifold family when station density matters more than per-station flow: Cv 0.1 per valve, because the flow path runs through the base. If one circuit point needs more, use an individual 3V2 body instead (Cv 0.18 at 1/8 in, 0.19 at 1/4 in, and vacuum-rated), or step to 3V3 (Cv 0.62, 1/4 in, vacuum-rated) for the highest flow in the 3V range; 3V1 is the low-power pick at 3.0 W DC. A double-acting cylinder cannot be driven by any 3-port valve - route that need to the AirTAC 4V series.

Match five points before ordering: initial state (NC here, and it cannot be changed after purchase), coil voltage (DC12V), electrical entry (DIN plug), station count (15) and exhaust type (centralised). Thread is PT as standard on this family; G and NPT are catalogue options to order.

Confirm before you order

  • ✓ Port size and thread (PT from stock; G / NPT to order)
  • ✓ Initial state — NC or NO, ordered up front
  • ✓ Coil voltage matches your controller output
  • ✓ Electrical entry — DIN plug or flying lead
  • ✓ Single valve, bare base, or complete assembly
  • ✓ Single-acting duty, not double-acting
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Stay within 0-0.8 MPa (0-114 psi) operating pressure.
  • check Match the coil voltage to your controller output.
  • check Use the manual override to test before powering up.
  • check Leave the exhaust port clear, or fit a silencer.
  • check Blank any unused station on the base before pressurising.
  • check Wiring by qualified personnel, per AirTAC documentation.

Airtac 3V2M Solenoid Valve 3V2MNCF-15F FAQ

It is a 15-station 3/2 NC DC12V assembly: Cv 0.1 per valve, operating pressure 0-0.8 MPa (0-114 psi), temperature -20 to 70 C, coil power 7.0 W per DC valve, protection IP65 (DIN 40050), PT1/8 ports with G and NPT available to order, direct-acting spring return, manual override fitted.

No. 3V2M uses a dedicated base gasket, and reversing or flipping that gasket does not change NC to NO. The initial state is built into the valve bodies you order. If any circuit needs a normally open function, order those stations as NO up front.

verified

Authorized Export Seller

Genuine AirTAC parts produced by the AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac 3V2M Solenoid Valve 3V2MNCF-15F

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 3V2MNCF-15F and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.