The AirTAC Airtac 3V2M Solenoid Valve 3V2MNCFI-10F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
The 3V2MNCFI-10F is a complete ten-station bank: ten normally closed 3/2 valve bodies mounted on a matched 10F base with one PT1/8 supply inlet and one shared wiring entry point. Every valve is direct-acting with a single solenoid and spring return, and the coaxial poppet shut-off holds a tight seal across the full 0-0.8 MPa range.
Each AC220V coil draws 7 VA, so a full bank under power presents 70 VA in total. The flying-lead construction gives you a pre-wired lead-out per valve instead of ten separate DIN plugs, which speeds cabinet routing. Because the valves are NC, every outlet stays vented until its coil energises - a natural failsafe for clamps and gates. IP65 (DIN 40050) protects the electrical parts.
| Model | Airtac 3V2M Solenoid Valve 3V2MNCFI-10F |
|---|---|
| Series | 3V2M |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Initial state | Normally closed |
| Item form | Complete assembly — 10 valves on a shared base |
| Exhaust | Centralised exhaust |
| Port size | 1/8 in |
| Thread | PT |
| Coil voltage | DC12V |
|---|---|
| Electrical entry | Flying lead (lead-out wire type) |
| Coil power | 7.0 W |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Not rated for vacuum |
| Flow coefficient | Cv 0.1 |
| Temperature | -20 to 70 C |
| Construction | Coaxial shut-off (poppet), base-mounted, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V2M catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V2M | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| 1/8 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| NC | Normally closed: no air at the outlet until the coil is energised. |
| DC12V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| I | Electrical entry: I = flying lead, otherwise a DIN plug. |
| 10F | 10 stations in one assembly, centralised exhaust. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
Ten single-acting clamping cylinders on a carton-sealing machine switch from one 3V2MNCFI-10F bank; a power cut leaves every clamp released because the valves are normally closed.
Divert gates along a parcel conveyor each take one station of this ten-valve assembly, sharing a single supply and wiring run down the conveyor frame.
An electronics end-of-line fixture with ten pusher or hold-down positions wires once to the manifold instead of terminating ten individual valves.
3V2M puts manifold density first, so flow per valve is Cv 0.1. When one circuit needs more, build that station around an individual 3V2 valve (Cv 0.18 at 1/8 in, 0.19 at 1/4 in, and vacuum-rated) or move it to 3V3 (Cv 0.62, 1/4 in, vacuum-rated); where the duty is light and power matters, 3V1 runs at just 3.0 W on DC. A 3/2 valve feeds or vents a single outlet - it never drives a double-acting cylinder, which calls for the AirTAC 4V series.
Match five points before ordering: initial state, coil voltage, electrical entry, station count and exhaust type, plus thread (PT standard here; G or NPT on request). The NC state is fixed at purchase - it cannot be converted afterwards, so order NO at the outset if you need normally open.
Confirm before you order
Each valve has Cv 0.1, operates at 0-0.8 MPa (0-114 psi) and -20 to 70 C, and its AC220V coil draws 7 VA, giving 70 VA for ten energised stations. Protection is IP65 (DIN 40050), ports are PT1/8, and the medium is air filtered to 40 um or finer without lubrication.
No. 3V2M relies on a dedicated base gasket, and flipping or refitting it does not convert normally closed to normally open. The state is decided at order, so choose the NO variant when ordering if your circuit needs air to pass before energisation.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.