The AirTAC Airtac 3V2M Solenoid Valve 3V2MNCFI-17F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
On the 3V2MNCFI-17F all seventeen positions discharge through one shared centralised exhaust port, so the machine builder fits a single silenced outlet rather than seventeen separate ones. Supply is just as consolidated: seventeen NC 3/2 valves sit on one dedicated base with PT1/8 ports and one air inlet gallery.
Each valve is direct-acting with a single DC12V solenoid and spring return; total coil load is 7.0 W per station, about 119 W or close to 9.9 A at 12 V if every output is held on together. Coaxial poppet sealing keeps each normally closed outlet tight until its coil opens it, and Cv 0.1 defines the flow available per position.
| Model | Airtac 3V2M Solenoid Valve 3V2MNCFI-17F |
|---|---|
| Series | 3V2M |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Initial state | Normally closed |
| Item form | Complete assembly — 17 valves on a shared base |
| Exhaust | Centralised exhaust |
| Port size | 1/8 in |
| Thread | PT |
| Coil voltage | DC12V |
|---|---|
| Electrical entry | Flying lead (lead-out wire type) |
| Coil power | 7.0 W |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Not rated for vacuum |
| Flow coefficient | Cv 0.1 |
| Temperature | -20 to 70 C |
| Construction | Coaxial shut-off (poppet), base-mounted, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V2M catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V2M | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| 1/8 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| NC | Normally closed: no air at the outlet until the coil is energised. |
| DC12V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| I | Electrical entry: I = flying lead, otherwise a DIN plug. |
| 17F | 17 stations in one assembly, centralised exhaust. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
Seventeen 3/2 pilots actuate diaphragm valves on a media filter skid, all fed and vented through the one manifold.
Seventeen spring-return block valves on a rotary filler cut each fill head in and out, driven from a common 12 V supply.
Guard-area clamp cylinders on a stamping press hold only while energised; the NC valves vent them the moment control power fails.
This 17-station bank concentrates supply and wiring on a single base at Cv 0.1 per valve. If one particular function needs a bigger opening, replace that valve with an individual 3V2 (Cv 0.18 at 1/8 in, 0.19 at 1/4 in, vacuum-rated) or a 3V3 (Cv 0.62, 1/4 in, vacuum-rated), while a 3V1 at 3.0 W DC covers low-power points. A 3/2 valve feeds or vents one line only - double-acting cylinders need the 5-port AirTAC 4V series.
Decide five points before ordering: NC versus NO (an NC valve cannot be turned into NO after purchase - flipping the base gasket will not do it), DC12V coil, flying-lead entry, 17 stations on a centralised-exhaust base (the -D independent-exhaust version is the alternative), and thread: PT is the standard on this family, with G and NPT as order options.
Confirm before you order
Per position: 3/2 direct-acting poppet valve, Cv 0.1 flow coefficient, 0-0.8 MPa working pressure, -20 to 70 C temperature range, DC12V coil at 7.0 W (AC versions 7 VA), IP65 protection. Ports are PT1/8; use air filtered to 40 um or finer; lubrication is not needed.
Centralised exhaust pipes all 17 stations into one mufflered outlet, which simplifies piping and keeps noise in one place. An independent-exhaust (-D) base vents each station separately - the better pick when you must capture, monitor or isolate the discharge of individual functions.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.