The AirTAC Airtac 3V2M Solenoid Valve 3V2MNCFI-5F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.

  • Valve type3/2-way (3-port, 2-position)
  • Initial stateNormally closed
  • Port size1/8 in
  • Coil voltageDC12V
  • Electrical entryFlying lead (lead-out wire type)
  • Stations5
  • Flow (Cv)0.1
  • Series3V2M
$210.97 $219.89Save 4% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every 3V2M manifold set voltage, station and exhaust option on one page All 3V2M manifold set codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac 3V2M Solenoid Valve 3V2MNCFI-5F

Five normally closed 3/2 valves share one 3V2M base in the 3V2MNCFI-5F, forming a five-circuit 12 V block wired on flying leads. Every valve is direct-acting with spring return and coaxial shut-off sealing, so each outlet sits vented until its coil is energised - the behaviour you want where an unpowered machine must be safe.

Check the power budget before you build: five DC coils at 7.0 W each total about 35 W, near 2.9 A at 12 V with all stations on, so the worst-case figure decides the supply. One air feed serves all five stations and exhaust is centralised to a single port, while the shared wiring panel keeps diagnostics simple. Cv 0.1 per station and manual overrides on every valve support quick setup. The NC state is chosen at ordering and cannot be reversed or converted afterwards.

Airtac 3V2M Solenoid Valve 3V2MNCFI-5F Technical Specifications

ModelAirtac 3V2M Solenoid Valve 3V2MNCFI-5F
Series3V2M
Valve type3/2-way (3-port, 2-position)
FunctionDirect-acting, single solenoid, spring return
Initial stateNormally closed
Item formComplete assembly — 5 valves on a shared base
ExhaustCentralised exhaust
Port size1/8 in
ThreadPT
Coil voltageDC12V
Electrical entryFlying lead (lead-out wire type)
Coil power7.0 W
Operating pressure0-0.8 MPa (0-114 psi)
Vacuum serviceNot rated for vacuum
Flow coefficientCv 0.1
Temperature-20 to 70 C
ConstructionCoaxial shut-off (poppet), base-mounted, spring return
ProtectionIP65 (DIN 40050)
MediumAir, filtered by a 40 µm or finer element. Lubrication not required.

Figures follow the official AirTAC 3V2M catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

The initial state cannot be changed after ordering. 3V2M uses a dedicated base gasket, and reversing or flipping that gasket does not convert NC to NO. Order the state you need up front.

Model Code: Airtac 3V2M Solenoid Valve 3V2MNCFI-5F

3V2MBody — sets the flow, the coil power and whether vacuum is rated.
1/8 inPort size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in.
NCNormally closed: no air at the outlet until the coil is energised.
DC12VCoil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V.
IElectrical entry: I = flying lead, otherwise a DIN plug.
5F5 stations in one assembly, centralised exhaust.
PTPort thread. PT ships from stock; G and NPT are available to order.

What a 3/2 Valve Does

A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.

That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.

It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.

Where the Airtac 3V2M Solenoid Valve 3V2MNCFI-5F Is Used

conveyor_belt

Bottling line gate control

Five NC valves on one 12 V manifold drive spring-return gates and stoppers along a bottling conveyor, sequenced from a PLC output card.

factory

Ceramic press safety interlocks

Five 12 V flying-lead circuits release guard interlock cylinders on a ceramic press, all vented safely at power-off through the central exhaust.

tune

Mixer drum choke actuators

A five-station 3V2M group toggles choke flaps on a batching mixer, tuned circuit by circuit without disturbing the shared supply or wiring.

Is the Airtac 3V2M Solenoid Valve 3V2MNCFI-5F the Right Part?

Before ordering, settle all five points: initial state (NC, fixed for life - no gasket flip or field trick changes it), DC12V voltage, flying-lead entry, 5 stations, centralised exhaust, plus thread choice where PT is the family standard and G or NPT are options written into the order.

This manifold favours density over flow: Cv 0.1 per valve against Cv 0.18-0.19 for an individual 3V2 and Cv 0.62 for a 3V3 at 1/4 inch, both of which are vacuum-rated where the 3V2M is not. For small-duty circuits the 3.0 W DC 3V1 body cuts coil load. If the actuator is a double-acting cylinder, specify the AirTAC 4V series instead.

Confirm before you order

  • ✓ Port size and thread (PT from stock; G / NPT to order)
  • ✓ Initial state — NC or NO, ordered up front
  • ✓ Coil voltage matches your controller output
  • ✓ Electrical entry — DIN plug or flying lead
  • ✓ Single valve, bare base, or complete assembly
  • ✓ Single-acting duty, not double-acting
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Stay within 0-0.8 MPa (0-114 psi) operating pressure.
  • check Match the coil voltage to your controller output.
  • check Use the manual override to test before powering up.
  • check Leave the exhaust port clear, or fit a silencer.
  • check Blank any unused station on the base before pressurising.
  • check Wiring by qualified personnel, per AirTAC documentation.

Airtac 3V2M Solenoid Valve 3V2MNCFI-5F FAQ

Five NC 3/2 valves, direct-acting, single solenoid, spring return, coaxial shut-off, on one manifold base. Cv 0.1 per valve, 0-0.8 MPa, -20 to 70 C, DC12V coils at 7.0 W each - about 35 W or roughly 2.9 A at 12 V if all five run together. IP65 (DIN 40050), PT1/8 ports, flying-lead entry, centralised exhaust, manual override per station, air filtered to 40 um or finer.

With no D code in the order, exhaust is centralised: all five stations vent through one shared port, which simplifies ducting and lets you fit a single silencer. Independent per-station exhaust is available on other 3V2M codes ordered with the D suffix. Air quality still matters for every station - use filtered air of 40 um or better, and no lubrication is required.

verified

Authorized Export Seller

Genuine AirTAC parts produced by the AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac 3V2M Solenoid Valve 3V2MNCFI-5F

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 3V2MNCFI-5F and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.