The AirTAC Airtac 3V2M Solenoid Valve 3V2MNCFI-8F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
Eight stations on one machined base is where the 3V2M layout earns its keep - and where its single compromise shows. Routing air through the base holds each valve to Cv 0.1, lower than an individually ported 3V2, so the 3V2MNCFI-8F is the right choice when panel space and wiring count matter more than per-station flow. Each of the eight sections is normally closed, direct-acting and spring-return, with a coaxial poppet for tight shut-off.
The DC12V coils come with flying leads fitted, eight pre-terminated lead-out wires feeding one common harness off a single supply. Budget the power honestly: 7.0 W per coil means 56 W, roughly 4.7 A at 12 V, with all eight energised at once. Coil sealing is IP65 (DIN 40050) and every body carries a manual override for stepping through the cycle.
| Model | Airtac 3V2M Solenoid Valve 3V2MNCFI-8F |
|---|---|
| Series | 3V2M |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Initial state | Normally closed |
| Item form | Complete assembly — 8 valves on a shared base |
| Exhaust | Centralised exhaust |
| Port size | 1/8 in |
| Thread | PT |
| Coil voltage | DC12V |
|---|---|
| Electrical entry | Flying lead (lead-out wire type) |
| Coil power | 7.0 W |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Not rated for vacuum |
| Flow coefficient | Cv 0.1 |
| Temperature | -20 to 70 C |
| Construction | Coaxial shut-off (poppet), base-mounted, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V2M catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V2M | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| 1/8 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| NC | Normally closed: no air at the outlet until the coil is energised. |
| DC12V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| I | Electrical entry: I = flying lead, otherwise a DIN plug. |
| 8F | 8 stations in one assembly, centralised exhaust. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
Pop-up diverter rollers in a small parcel sorter, one NC station per module, all supplied and wired from a single point at the end of the frame.
Locating clamps on a fabrication jig, each one held by a spring-return cylinder fed from its own station and released on power loss.
Gated air nozzles clearing chips from a machining envelope, energised only during the blow-off step because the NC sections stay shut otherwise.
Five decisions set this order: NC initial state (fixed at purchase - the base gasket cannot be flipped to change it, so confirm NO up front if you need air to pass while de-energised), DC12V coil, flying-lead entry, eight stations, and centralised exhaust on the blank -8F code (independent per-station exhaust is the -8FD variant). Thread is PT1/8 as standard; G and NPT are catalogue options. Compare flow openly: Cv 0.1 here versus Cv 0.18 at 1/8 in or 0.19 at 1/4 in on a standalone 3V2, and Cv 0.62 on a 3V3 - move a high-flow station to one of those, and drop modest duties to 3V1 at 3.0 W DC. Double-acting cylinders belong on a 5-port AirTAC 4V valve.
Confirm before you order
Eight normally closed 3/2 poppet valves, direct-acting with spring return, on one shared base: Cv 0.1 per station, 0-0.8 MPa operating pressure, -20 to 70 C temperature, DC12V coils at 7.0 W each, IP65 (DIN 40050). PT1/8 ports are standard; G and NPT are order options. Air must pass a 40 um or finer filter and lubrication is not required.
No. 3V2M uses a dedicated base gasket, and reversing that gasket does not convert a valve between NC and NO; the initial state is built into the valve and must be ordered correctly. If any of the eight positions should pass air while de-energised, order those valves as NO under a separate 3V2MNO code when you place the RFQ.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.