AirTAC 3V2M · Valve Manifold Assembly

Airtac 3V2M Solenoid Valve 3V2MNOA-11F

The AirTAC Airtac 3V2M Solenoid Valve 3V2MNOA-11F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.

  • Valve type3/2-way (3-port, 2-position)
  • Initial stateNormally open
  • Port size1/8 in
  • Coil voltageAC220V
  • Electrical entryDIN plug (DIN socket type)
  • Stations11
  • Flow (Cv)0.1
  • Series3V2M
$452.05 $466.95Save 3% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every 3V2M manifold set voltage, station and exhaust option on one page All 3V2M manifold set codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac 3V2M Solenoid Valve 3V2MNOA-11F

With eleven 3/2 normally open valves on a single manifold, 3V2MNOA-11F turns eleven separate valve installations into one plumb-and-wire job: a common supply feeds all stations, and the centralised exhaust collects every vent at one threaded port on the PT1/8 base.

The maintenance win is the wiring: all eleven AC220V DIN-plug coils sit on the same base run, so testing or swapping a station takes minutes instead of re-piping a machine. Each coil draws 7 VA - about 77 VA across eleven energised stations - with IP65 (DIN 40050) protection. The spring-return NO bodies pass air whenever the coil is off and vent their outlet when energised, and the manual override on each body helps during commissioning. Order the state you need: the dedicated base gasket cannot be reversed to change NO to NC.

Airtac 3V2M Solenoid Valve 3V2MNOA-11F Technical Specifications

ModelAirtac 3V2M Solenoid Valve 3V2MNOA-11F
Series3V2M
Valve type3/2-way (3-port, 2-position)
FunctionDirect-acting, single solenoid, spring return
Initial stateNormally open
Item formComplete assembly — 11 valves on a shared base
ExhaustCentralised exhaust
Port size1/8 in
ThreadPT
Coil voltageAC220V
Electrical entryDIN plug (DIN socket type)
Coil power7 VA
Operating pressure0-0.8 MPa (0-114 psi)
Vacuum serviceNot rated for vacuum
Flow coefficientCv 0.1
Temperature-20 to 70 C
ConstructionCoaxial shut-off (poppet), base-mounted, spring return
ProtectionIP65 (DIN 40050)
MediumAir, filtered by a 40 µm or finer element. Lubrication not required.

Figures follow the official AirTAC 3V2M catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

The initial state cannot be changed after ordering. 3V2M uses a dedicated base gasket, and reversing or flipping that gasket does not convert NC to NO. Order the state you need up front.

Model Code: Airtac 3V2M Solenoid Valve 3V2MNOA-11F

3V2MBody — sets the flow, the coil power and whether vacuum is rated.
1/8 inPort size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in.
NONormally open: air passes until the coil is energised.
AC220VCoil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V.
—Electrical entry: I = flying lead, otherwise a DIN plug.
11F11 stations in one assembly, centralised exhaust.
PTPort thread. PT ships from stock; G and NPT are available to order.

What a 3/2 Valve Does

A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.

That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.

It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.

Where the Airtac 3V2M Solenoid Valve 3V2MNOA-11F Is Used

build

Hold-down clamps on a woodworking press

Eleven normally open stations hold eleven clamps closed with power off; each coil is energised in turn to vent and release, and the shared base wiring makes a stuck clamp simple to isolate.

science

Blow-back pulse valves on a filter dust collector

Normally open stations keep the pulse lines charged and fire in sequence to clean the filter bags; the centralised exhaust carries the discharged air to one silencer.

local_shipping

Dock leveller locks at a loading bay

Spring-return locking cylinders on dock levellers stay engaged whenever power fails, because the normally open stations keep supplying them; control power vents a station only to release.

Is the Airtac 3V2M Solenoid Valve 3V2MNOA-11F the Right Part?

Choose 3V2MNOA-11F when eleven stations must share one supply and be serviced quickly. Settle five points first: initial state NO, coil AC220V, entry DIN plug, 11 stations, centralised exhaust, plus thread (PT standard on this family; G and NPT are options to order). Note the flow trade-off: running the path through the base gives Cv 0.1 per station, so if any single station needs more, fit an individual 3V2 there (Cv 0.18 at 1/8 in, 0.19 at 1/4 in, also vacuum-rated) or a 3V3 (Cv 0.62 at 1/4 in, vacuum-rated), and use 3V1 at 3.0 W DC where low power matters. The normally open state cannot be converted after purchase, and any double-acting cylinder belongs on the 5-port AirTAC 4V range.

Confirm before you order

  • ✓ Port size and thread (PT from stock; G / NPT to order)
  • ✓ Initial state — NC or NO, ordered up front
  • ✓ Coil voltage matches your controller output
  • ✓ Electrical entry — DIN plug or flying lead
  • ✓ Single valve, bare base, or complete assembly
  • ✓ Single-acting duty, not double-acting
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Stay within 0-0.8 MPa (0-114 psi) operating pressure.
  • check Match the coil voltage to your controller output.
  • check Use the manual override to test before powering up.
  • check Leave the exhaust port clear, or fit a silencer.
  • check Blank any unused station on the base before pressurising.
  • check Wiring by qualified personnel, per AirTAC documentation.

Airtac 3V2M Solenoid Valve 3V2MNOA-11F FAQ

Eleven 3/2 normally open stations, Cv 0.1 each, operating pressure 0-0.8 MPa (0-114 psi), temperature range -20 to 70 C, 7 VA per AC220V coil (about 77 VA if all eleven energise; DC versions draw 7.0 W per coil), IP65 (DIN 40050), PT1/8 ports, direct-acting spring-return valves with manual override.

Each 3/2 station has one outlet, so it suits single-acting spring-return cylinders, air blow, clamping and pilot duty for larger process valves. A double-acting cylinder needs two outlet ports and a 5-port valve - use the AirTAC 4V series for that. Also note the normally open state is fixed at purchase: flipping the dedicated base gasket does not convert NO to NC.

verified

Authorized Export Seller

Genuine AirTAC parts produced by the AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac 3V2M Solenoid Valve 3V2MNOA-11F

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 3V2MNOA-11F and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.