AirTAC 3V2M · Valve Manifold Assembly

Airtac 3V2M Solenoid Valve 3V2MNOA-15F

The AirTAC Airtac 3V2M Solenoid Valve 3V2MNOA-15F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.

  • Valve type3/2-way (3-port, 2-position)
  • Initial stateNormally open
  • Port size1/8 in
  • Coil voltageAC220V
  • Electrical entryDIN plug (DIN socket type)
  • Stations15
  • Flow (Cv)0.1
  • Series3V2M
$612.77 $631.66Save 2% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every 3V2M manifold set voltage, station and exhaust option on one page All 3V2M manifold set codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac 3V2M Solenoid Valve 3V2MNOA-15F

A normally open valve is the correct pick where the process must keep receiving air through a power failure, and the 3V2MNOA-15F provides fifteen such circuits in one machined block. Each station is a 3/2 direct-acting poppet valve with spring return, an AC220V coil drawing 7 VA, and Cv 0.1 of flow through the shared base gallery. Energise a station and it vents; cut the power and it passes air again without any stored command.

Mounting fifteen valves on one base collapses the plumbing into a single assembly: one supply, one connector set, one exhaust path. Air leaves centrally through the base, so a lone silencer serves all fifteen stations. The NO initial state is set at the factory - AirTAC's dedicated base gasket cannot be reversed to convert NO to NC, so settle the state before ordering.

Airtac 3V2M Solenoid Valve 3V2MNOA-15F Technical Specifications

ModelAirtac 3V2M Solenoid Valve 3V2MNOA-15F
Series3V2M
Valve type3/2-way (3-port, 2-position)
FunctionDirect-acting, single solenoid, spring return
Initial stateNormally open
Item formComplete assembly — 15 valves on a shared base
ExhaustCentralised exhaust
Port size1/8 in
ThreadPT
Coil voltageAC220V
Electrical entryDIN plug (DIN socket type)
Coil power7 VA
Operating pressure0-0.8 MPa (0-114 psi)
Vacuum serviceNot rated for vacuum
Flow coefficientCv 0.1
Temperature-20 to 70 C
ConstructionCoaxial shut-off (poppet), base-mounted, spring return
ProtectionIP65 (DIN 40050)
MediumAir, filtered by a 40 µm or finer element. Lubrication not required.

Figures follow the official AirTAC 3V2M catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

The initial state cannot be changed after ordering. 3V2M uses a dedicated base gasket, and reversing or flipping that gasket does not convert NC to NO. Order the state you need up front.

Model Code: Airtac 3V2M Solenoid Valve 3V2MNOA-15F

3V2MBody — sets the flow, the coil power and whether vacuum is rated.
1/8 inPort size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in.
NONormally open: air passes until the coil is energised.
AC220VCoil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V.
—Electrical entry: I = flying lead, otherwise a DIN plug.
15F15 stations in one assembly, centralised exhaust.
PTPort thread. PT ships from stock; G and NPT are available to order.

What a 3/2 Valve Does

A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.

That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.

It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.

Where the Airtac 3V2M Solenoid Valve 3V2MNOA-15F Is Used

air

Glove box inerting jets

A powder-handling glove box keeps fifteen purge jets flowing through NO stations, so inerting continues automatically whenever the controls lose power.

tune

Glue-dot applicator nozzles

A corrugated box gluing head runs fifteen nozzles, each nozzle's supply cut by its own NO station the instant the controller signals a pattern stop.

valve

Process valve pilot bank

Fifteen large process valves are piloted from one 3V2M base; the NO pilot logic keeps each main actuator fed if the PLC supply fails, holding the process in its safe state.

Is the Airtac 3V2M Solenoid Valve 3V2MNOA-15F the Right Part?

Confirm five things before you buy: normally open state, AC220V voltage, DIN plug entry, fifteen stations, centralised exhaust, and thread (PT standard; G and NPT are order options). There is no field conversion - the NO state lives in the valve bodies, and flipping the dedicated base gasket changes nothing.

Flow-wise the 3V2M trades Cv 0.1 per station for base-mounted density. An individually ported 3V2 gives Cv 0.18 at 1/8 in or Cv 0.19 at 1/4 in plus a vacuum rating; step up to the 3V3 (Cv 0.62, 1/4 in) for the most air the 3V family delivers. If coil draw is the concern, the 3V1 needs only 3.0 W on DC. Double-acting cylinders need 5 ports - that is the AirTAC 4V series.

Confirm before you order

  • ✓ Port size and thread (PT from stock; G / NPT to order)
  • ✓ Initial state — NC or NO, ordered up front
  • ✓ Coil voltage matches your controller output
  • ✓ Electrical entry — DIN plug or flying lead
  • ✓ Single valve, bare base, or complete assembly
  • ✓ Single-acting duty, not double-acting
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Stay within 0-0.8 MPa (0-114 psi) operating pressure.
  • check Match the coil voltage to your controller output.
  • check Use the manual override to test before powering up.
  • check Leave the exhaust port clear, or fit a silencer.
  • check Blank any unused station on the base before pressurising.
  • check Wiring by qualified personnel, per AirTAC documentation.

Airtac 3V2M Solenoid Valve 3V2MNOA-15F FAQ

Fifteen 3/2 normally open stations, Cv 0.1 each, pressure 0-0.8 MPa (0-114 psi), temperature -20 to 70 C, IP65 (DIN 40050) and a manual override on every valve. AC220V coils at 7 VA apiece give 105 VA connected; DC builds of the family draw 7.0 W per coil. Ports are PT1/8, with G and NPT as order options.

This assembly vents exhaust through one shared port on the base, so a single silencer and duct serve all fifteen stations - compact and simple, but back-pressure is shared between stations. If a circuit must vent on its own, order the -D independent-exhaust version of the base instead.

verified

Authorized Export Seller

Genuine AirTAC parts produced by the AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac 3V2M Solenoid Valve 3V2MNOA-15F

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 3V2MNOA-15F and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.