The AirTAC Airtac 3V2M Solenoid Valve 3V2MNOA-17F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
The 3V2MNOA-17F is a complete 17-station manifold assembly built from seventeen 3/2 normally open solenoid valves on a dedicated AirTAC base. Being normally open, every outlet passes air while de-energised and vents the moment its 7 VA AC220V coil is switched on - the fail-flow direction that many blow-off and gating circuits require.
Each valve is direct-acting with spring return and a coaxial shut-off poppet for tight sealing. The shared base feeds all seventeen stations from one air supply and one wiring harness, and every body carries a manual override for setup and commissioning. Flow is Cv 0.1 per station through PT1/8 ports.
| Model | Airtac 3V2M Solenoid Valve 3V2MNOA-17F |
|---|---|
| Series | 3V2M |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Initial state | Normally open |
| Item form | Complete assembly — 17 valves on a shared base |
| Exhaust | Centralised exhaust |
| Port size | 1/8 in |
| Thread | PT |
| Coil voltage | AC220V |
|---|---|
| Electrical entry | DIN plug (DIN socket type) |
| Coil power | 7 VA |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Not rated for vacuum |
| Flow coefficient | Cv 0.1 |
| Temperature | -20 to 70 C |
| Construction | Coaxial shut-off (poppet), base-mounted, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V2M catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V2M | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| 1/8 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| NO | Normally open: air passes until the coil is energised. |
| AC220V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| — | Electrical entry: I = flying lead, otherwise a DIN plug. |
| 17F | 17 stations in one assembly, centralised exhaust. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
Seventeen air nozzles clear loose solder dust from printed circuit boards before inspection; the normally open function keeps the nozzles blowing even if a PLC output fails, so boards never reach the camera dirty.
On a float glass line the air knives must not stop when a controller trips; NO valves leave cooling air flowing through the failure, protecting the ribbon while the fault is traced.
Seventeen single-acting ejector pins on a stamping die stay extended while de-energised; energising each coil vents its cylinder so the pin retracts only when the press control commands it.
Order the state you need, because a 3V2M is normally open only as ordered - the dedicated base gasket cannot be flipped to turn NO into NC after purchase. For this assembly check five points: NO state, AC220V coil, DIN plug entry, 17 stations and centralised exhaust, with PT as the standard thread (G or NPT available as order options).
At Cv 0.1 per station, 3V2M buys density rather than flow. If a single station needs more, spec an individual 3V2 (Cv 0.18 at 1/8 in, 0.19 at 1/4 in, and vacuum-rated) or a 3V3 (Cv 0.62, 1/4 in, vacuum-rated); where duty is light, 3V1 saves power at 3.0 W DC. A double-acting cylinder is outside any 3-port valve - that job belongs to the 4V series.
Confirm before you order
Each of the seventeen valves is a 3/2 normally open unit with Cv 0.1, rated 0-0.8 MPa and -20 to 70 C. The AC220V coils draw 7 VA each (119 VA if all fire at once) and meet IP65 (DIN 40050). Ports are PT1/8 and the exhaust is centralised.
No. AirTAC's 3V2M uses a dedicated base gasket and reversing it does not change the initial state - the valve is NO because that is how it was built. Order NC from the start; any station needing the opposite state gets its own correctly coded valve.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.