The AirTAC Airtac 3V2M Solenoid Valve 3V2MNOA-3F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
A 3V2MNOA-3F puts three normally open 3/2 solenoid valves on one base, so a three-function machine section gets a single air inlet, a single wiring loom and one centralised exhaust instead of three separate threaded valves. With NO coils, each station feeds its outlet until its 7 VA AC220V coil is energised, then the spring vents it - useful where a power failure should leave the supply path open.
Every valve is direct-acting with coaxial poppet sealing and works across 0 to 0.8 MPa, and the manual override on each body makes staged start-up straightforward. Shared wiring also concentrates fault-finding: a dead station is traced at the base, not around the machine.
| Model | Airtac 3V2M Solenoid Valve 3V2MNOA-3F |
|---|---|
| Series | 3V2M |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Initial state | Normally open |
| Item form | Complete assembly — 3 valves on a shared base |
| Exhaust | Centralised exhaust |
| Port size | 1/8 in |
| Thread | PT |
| Coil voltage | AC220V |
|---|---|
| Electrical entry | DIN plug (DIN socket type) |
| Coil power | 7 VA |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Not rated for vacuum |
| Flow coefficient | Cv 0.1 |
| Temperature | -20 to 70 C |
| Construction | Coaxial shut-off (poppet), base-mounted, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V2M catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V2M | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| 1/8 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| NO | Normally open: air passes until the coil is energised. |
| AC220V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| — | Electrical entry: I = flying lead, otherwise a DIN plug. |
| 3F | 3 stations in one assembly, centralised exhaust. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
A laboratory plate washer sequencing three rinse jets: each NO valve feeds its jet until the controller energises the coil to stop flow, all three driven from one base and one wiring loom.
Three air curtains in a wire-cutting cell that sweep cut ends clear between cycles, each on its own station but sharing one supply and one exhaust route.
A high-cycle escapement feeding parts to a sorter, where the normally open valve keeps the feed cylinder pressurised between cycles and vents it on each energise pulse.
Three stations on one base is where shared wiring starts to pay off, but flow still matters: 3V2M is Cv 0.1 per station, against Cv 0.18 (1/8 in) and 0.19 (1/4 in) for a stand-alone 3V2 and Cv 0.62 for 3V3, both of which add vacuum capability 3V2M lacks. If the duty is light and the power budget tight, 3V1 draws just 3.0 W on DC. A 3/2 valve cannot drive a double-acting cylinder - that call goes to the AirTAC 4V series.
Order against the five-point list: NO state, AC220V, DIN plug entry, 3 stations, centralised exhaust, plus thread (PT standard, G or NPT to order). The initial state is permanent once purchased.
Confirm before you order
Flow coefficient Cv 0.1, pressure 0-0.8 MPa (0-114 psi), operating temperature -20 to 70 C, coil 7 VA on AC220V (7.0 W on DC variants), IP65 rating, PT1/8 ports, three 3/2 NO spring-return valves.
Single-acting spring-return cylinders, clamping, on/off blow and pilot duty for larger process valves - one outlet, fed or vented, per valve. A double-acting cylinder needs two outlet ports, which a 3/2 valve does not have; that job belongs to the AirTAC 4V 5-port series.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.