The AirTAC Airtac 3V2M Solenoid Valve 3V2MNOA-5F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
The 3V2MNOA-5F is a complete AirTAC assembly: five 3/2 normally open valves already built onto a dedicated 5-station base. Every valve is direct-acting with a single solenoid and spring return, built on a coaxial shut-off poppet that seals well. Because all five share one base, the stations draw from a single air supply and a single wiring run.
In the NO version, air flows to each outlet while the coil is off; energising the AC220V coil shuts that station. Each station is rated Cv 0.1, a flow coefficient suited to small single-acting loads rather than high-demand cylinders. The DIN plug entry keeps wiring to a simple push-on connector. Port thread is PT1/8, with G and NPT available to order.
| Model | Airtac 3V2M Solenoid Valve 3V2MNOA-5F |
|---|---|
| Series | 3V2M |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Initial state | Normally open |
| Item form | Complete assembly — 5 valves on a shared base |
| Exhaust | Centralised exhaust |
| Port size | 1/8 in |
| Thread | PT |
| Coil voltage | AC220V |
|---|---|
| Electrical entry | DIN plug (DIN socket type) |
| Coil power | 7 VA |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Not rated for vacuum |
| Flow coefficient | Cv 0.1 |
| Temperature | -20 to 70 C |
| Construction | Coaxial shut-off (poppet), base-mounted, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V2M catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V2M | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| 1/8 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| NO | Normally open: air passes until the coil is energised. |
| AC220V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| — | Electrical entry: I = flying lead, otherwise a DIN plug. |
| 5F | 5 stations in one assembly, centralised exhaust. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
On a carton sealing line, normally open stations keep air knives and reject pushers supplied even if the PLC drops out; power is applied only to stop a station.
Cooling air at a CNC drill head should keep flowing when control power fails; a NO station guarantees the blast until its coil is energised to shut it.
Single-acting clamps on a machining fixture stay actuated at rest with NO valves, venting to release only when the solenoid is energised.
Choose 3V2M when station density matters more than raw flow: the path through the base costs flow, giving Cv 0.1 here against Cv 0.18 on an individual 3V2 at the same 1/8 inch size. Step up to 3V3 (Cv 0.62, 1/4 inch, vacuum-rated) when a station needs real volume, or pick 3V1 (3.0 W DC) for light duty at lower power.
The normally open state is fixed: the dedicated base gasket cannot be flipped to convert NO to NC, so order the state you need. A 3/2 valve drives single-acting spring-return cylinders, blow and pilot duty only - for double-acting cylinders you need the 5-port AirTAC 4V series. Match the five points before ordering: initial state (NO), coil voltage (AC220V), electrical entry (DIN plug), station count (5), exhaust type (centralised), plus thread (PT standard; G or NPT on request).
Confirm before you order
Each of the five valves is a 3/2 direct-acting spring-return unit with Cv 0.1, operating pressure 0-0.8 MPa (0-114 psi), temperature range -20 to 70 C, AC coil power 7 VA per station (35 VA if all five are energised) and IP65 protection to DIN 40050. Medium is air filtered to 40 um or finer; lubrication is not required.
No. The initial state is fixed at manufacture, and the 3V2M dedicated base gasket does not convert NO to NC when reversed. If any station should be closed at rest, order it as an NC valve; NC and NO valves can be mixed across the stations of one base.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.