verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC 3V2M · Valve Manifold Assembly

Airtac 3V2M Solenoid Valve 3V2MNOAI-7F

The AirTAC Airtac 3V2M Solenoid Valve 3V2MNOAI-7F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.

  • Valve type3/2-way (3-port, 2-position)
  • Initial stateNormally open
  • Port size1/8 in
  • Coil voltageAC220V
  • Electrical entryFlying lead (lead-out wire type)
  • Stations7
  • Flow (Cv)0.1
  • Series3V2M
$291.33 $302.24Save 3% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every 3V2M manifold set voltage, station and exhaust option on one page All 3V2M manifold set codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac 3V2M Solenoid Valve 3V2MNOAI-7F

At seven stations the 3V2MNOAI-7F shows what the 3V2M platform is built for: seven normally open 3/2 valves on one base, sharing a unified supply and a unified wiring loom, each valve driven by a 7 VA AC220V coil on a flying lead. When a station misbehaves, you troubleshoot one valve on the bank instead of seven scattered units.

Each valve shifts with a spring return and a coaxial poppet seal, direct-acting with no pilot air required. In NO duty the outlet passes air until the coil is energised - convenient for circuits that must vent or blow by default. Total energised draw is 49 VA across seven stations; flow stays at Cv 0.1 per valve.

Airtac 3V2M Solenoid Valve 3V2MNOAI-7F Technical Specifications

ModelAirtac 3V2M Solenoid Valve 3V2MNOAI-7F
Series3V2M
Valve type3/2-way (3-port, 2-position)
FunctionDirect-acting, single solenoid, spring return
Initial stateNormally open
Item formComplete assembly — 7 valves on a shared base
ExhaustCentralised exhaust
Port size1/8 in
ThreadPT
Coil voltageAC220V
Electrical entryFlying lead (lead-out wire type)
Coil power7 VA
Operating pressure0-0.8 MPa (0-114 psi)
Vacuum serviceNot rated for vacuum
Flow coefficientCv 0.1
Temperature-20 to 70 C
ConstructionCoaxial shut-off (poppet), base-mounted, spring return
ProtectionIP65 (DIN 40050)
MediumAir, filtered by a 40 µm or finer element. Lubrication not required.

Figures follow the official AirTAC 3V2M catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

The initial state cannot be changed after ordering. 3V2M uses a dedicated base gasket, and reversing or flipping that gasket does not convert NC to NO. Order the state you need up front.

Model Code: Airtac 3V2M Solenoid Valve 3V2MNOAI-7F

3V2MBody — sets the flow, the coil power and whether vacuum is rated.
1/8 inPort size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in.
NONormally open: air passes until the coil is energised.
AC220VCoil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V.
IElectrical entry: I = flying lead, otherwise a DIN plug.
7F7 stations in one assembly, centralised exhaust.
PTPort thread. PT ships from stock; G and NPT are available to order.

What a 3/2 Valve Does

A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.

That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.

It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.

Where the Airtac 3V2M Solenoid Valve 3V2MNOAI-7F Is Used

science

Environmental chamber dampers

In a university materials lab, seven normally open stations open spring-return vent dampers on an environmental chamber whenever supply is live; energising a coil closes that damper for a test cycle.

shield

Solvent store vent stacks

At a coating plant's solvent store, the NO valves keep spring-return vent stack actuators pressurised open by default; energising a station vents and closes its stack under an interlock signal.

build

Robotic welding fixture clamps

A robotic welding cell clamps seven sheet-metal parts with spring-return cylinders fed by the normally open valves, so clamps engage automatically on air-up and release station by station under robot command.

Is the Airtac 3V2M Solenoid Valve 3V2MNOAI-7F the Right Part?

Confirm the five ordering points - NO initial state, AC220V coils, flying-lead entry, seven stations, centralised exhaust - plus thread: PT is standard on this family, with G and NPT as options to order. The normally open state cannot be converted after purchase; flipping the dedicated base gasket does not change it.

If a circuit needs more than Cv 0.1 per valve, move that circuit to an individual 3V2 (Cv 0.18 at 1/8 inch, 0.19 at 1/4 inch, vacuum-rated) or to 3V3 (Cv 0.62, 1/4 inch, vacuum-rated); 3V1 at 3.0 W DC covers low-power duty. This 3/2 manifold never drives double-acting cylinders - specify the AirTAC 4V series for those.

Confirm before you order

  • ✓ Port size and thread (PT from stock; G / NPT to order)
  • ✓ Initial state — NC or NO, ordered up front
  • ✓ Coil voltage matches your controller output
  • ✓ Electrical entry — DIN plug or flying lead
  • ✓ Single valve, bare base, or complete assembly
  • ✓ Single-acting duty, not double-acting
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Stay within 0-0.8 MPa (0-114 psi) operating pressure.
  • check Match the coil voltage to your controller output.
  • check Use the manual override to test before powering up.
  • check Leave the exhaust port clear, or fit a silencer.
  • check Blank any unused station on the base before pressurising.
  • check Wiring by qualified personnel, per AirTAC documentation.

Airtac 3V2M Solenoid Valve 3V2MNOAI-7F FAQ

Per valve: Cv 0.1, operating pressure 0-0.8 MPa (0-114 psi), temperature -20 to 70 C, AC220V coil at 7 VA (49 VA across all seven stations energised), IP65 rating to DIN 40050. Ports are PT1/8, with air filtered to 40 um or finer and no lubrication needed.

Every AC220V coil draws 7 VA, so seven stations energised together pull about 49 VA through the shared flying-lead loom. Size the control transformer for that worst case and land each flying lead per station, so a faulty coil can be isolated without disturbing the rest of the bank.

verified

Authorized Export Seller

Genuine AirTAC parts produced by the AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac 3V2M Solenoid Valve 3V2MNOAI-7F

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 3V2MNOAI-7F and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.