verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC 3V2M · Valve Manifold Assembly

Airtac 3V2M Solenoid Valve 3V2MNOB-19F

The AirTAC Airtac 3V2M Solenoid Valve 3V2MNOB-19F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.

  • Valve type3/2-way (3-port, 2-position)
  • Initial stateNormally open
  • Port size1/8 in
  • Coil voltageDC24V
  • Electrical entryDIN plug (DIN socket type)
  • Stations19
  • Flow (Cv)0.1
  • Series3V2M
$773.50 $796.37Save 2% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every 3V2M manifold set voltage, station and exhaust option on one page All 3V2M manifold set codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac 3V2M Solenoid Valve 3V2MNOB-19F

The 3V2MNOB-19F is a complete 19-station manifold assembly: nineteen 3/2 normally open valve bodies on one shared 3V2M base. Every valve is direct-acting with a spring return and a coaxial poppet that seals the flow path positively. Because the NO bodies pass air to their outlets while de-energised, the whole bank is live the moment air supply is turned on.

One air feed and one wiring run serve all 19 valves, so a fault can be traced station by station without chasing separate hoses and cables. Each DC24V coil draws 7.0 W, so a fully energised 19-station bank needs about 133 W, roughly 5.5 A at 24 V - size the supply for that worst case. Coils are IP65 and plug into DIN sockets; the common exhaust port routes all vented air to one silencer.

Airtac 3V2M Solenoid Valve 3V2MNOB-19F Technical Specifications

ModelAirtac 3V2M Solenoid Valve 3V2MNOB-19F
Series3V2M
Valve type3/2-way (3-port, 2-position)
FunctionDirect-acting, single solenoid, spring return
Initial stateNormally open
Item formComplete assembly — 19 valves on a shared base
ExhaustCentralised exhaust
Port size1/8 in
ThreadPT
Coil voltageDC24V
Electrical entryDIN plug (DIN socket type)
Coil power7.0 W
Operating pressure0-0.8 MPa (0-114 psi)
Vacuum serviceNot rated for vacuum
Flow coefficientCv 0.1
Temperature-20 to 70 C
ConstructionCoaxial shut-off (poppet), base-mounted, spring return
ProtectionIP65 (DIN 40050)
MediumAir, filtered by a 40 µm or finer element. Lubrication not required.

Figures follow the official AirTAC 3V2M catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

The initial state cannot be changed after ordering. 3V2M uses a dedicated base gasket, and reversing or flipping that gasket does not convert NC to NO. Order the state you need up front.

Model Code: Airtac 3V2M Solenoid Valve 3V2MNOB-19F

3V2MBody — sets the flow, the coil power and whether vacuum is rated.
1/8 inPort size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in.
NONormally open: air passes until the coil is energised.
DC24VCoil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V.
—Electrical entry: I = flying lead, otherwise a DIN plug.
19F19 stations in one assembly, centralised exhaust.
PTPort thread. PT ships from stock; G and NPT are available to order.

What a 3/2 Valve Does

A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.

That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.

It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.

Where the Airtac 3V2M Solenoid Valve 3V2MNOB-19F Is Used

view_module

Palletiser head clamps

Nineteen spring-return clamps on a palletising head hold cartons in place. As a NO bank they stay clamped while the machine is idle and release only when the PLC energises each station.

conveyor_belt

Bottling line gate cylinders

Gating cylinders that meter bottles into lanes along a filling line. Each station vents independently of its neighbours while sharing one supply and one exhaust port.

settings_input_component

Robot gripper release valves

Gripper release valves in a robotic pick-and-place cell. The DIN plugs keep all 19 coil connections on one tidy harness along the robot frame.

Is the Airtac 3V2M Solenoid Valve 3V2MNOB-19F the Right Part?

This assembly suits dense multi-station panels where Cv 0.1 per valve is enough. When a single station needs more flow, fit an individual 3V2 (Cv 0.18 at 1/8 inch) or 3V3 (Cv 0.62 at 1/4 inch, both vacuum-rated) beside the manifold; for low-power duty the 3V1 draws only 3.0 W on DC. If any actuator on the machine is a double-acting cylinder, move to the AirTAC 4V series instead.

Ordering checklist: normally open state (which cannot be changed after purchase, so never count on flipping the base gasket), DC24V coil, DIN plug entry, 19 stations, centralised exhaust, PT1/8 thread. G and NPT threads are catalogue options you can order.

Confirm before you order

  • ✓ Port size and thread (PT from stock; G / NPT to order)
  • ✓ Initial state — NC or NO, ordered up front
  • ✓ Coil voltage matches your controller output
  • ✓ Electrical entry — DIN plug or flying lead
  • ✓ Single valve, bare base, or complete assembly
  • ✓ Single-acting duty, not double-acting
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Stay within 0-0.8 MPa (0-114 psi) operating pressure.
  • check Match the coil voltage to your controller output.
  • check Use the manual override to test before powering up.
  • check Leave the exhaust port clear, or fit a silencer.
  • check Blank any unused station on the base before pressurising.
  • check Wiring by qualified personnel, per AirTAC documentation.

Airtac 3V2M Solenoid Valve 3V2MNOB-19F FAQ

Each valve is 3/2 normally open, direct-acting with spring return. Flow coefficient Cv 0.1. Operating pressure 0-0.8 MPa (0-114 psi). Media temperature -20 to 70 C. DC24V coil power 7.0 W per station, about 133 W for 19 energised stations. Protection IP65 (DIN 40050). Port PT1/8; medium is air filtered to 40 um or finer.

No. The initial state is fixed by how the valve is built, and the dedicated 3V2M base gasket cannot be flipped or adjusted to swap NO to NC. AirTAC states this explicitly in the catalogue. If a station must fail closed, order that valve as NC when you place the order.

verified

Authorized Export Seller

Genuine AirTAC parts produced by the AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac 3V2M Solenoid Valve 3V2MNOB-19F

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 3V2MNOB-19F and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.