The AirTAC Airtac 3V2M Solenoid Valve 3V2MNOBI-2F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
The 3V2MNOBI-2F pairs two 3V2M normally open valve bodies with a dedicated 2-station base, ordered and installed as one assembly. Each valve is a direct-acting, coaxial poppet 3/2 unit with spring return and Cv 0.1: air passes from supply to outlet while the AC220V coil is off, and the outlet vents to exhaust the moment it is energised. This inverted logic suits circuits where the idle condition is airflow on.
Electrical entry is a flying lead, so each coil connects through a pre-wired lead-out instead of a DIN socket - handy in tight cabinets. Both stations share one supply and one wiring route tapped from the base, so a misbehaving circuit is located by its position on the manifold rather than by tracing separate harnesses.
| Model | Airtac 3V2M Solenoid Valve 3V2MNOBI-2F |
|---|---|
| Series | 3V2M |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Initial state | Normally open |
| Item form | Complete assembly — 2 valves on a shared base |
| Exhaust | Centralised exhaust |
| Port size | 1/8 in |
| Thread | PT |
| Coil voltage | DC24V |
|---|---|
| Electrical entry | Flying lead (lead-out wire type) |
| Coil power | 7.0 W |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Not rated for vacuum |
| Flow coefficient | Cv 0.1 |
| Temperature | -20 to 70 C |
| Construction | Coaxial shut-off (poppet), base-mounted, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V2M catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V2M | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| 1/8 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| NO | Normally open: air passes until the coil is energised. |
| DC24V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| I | Electrical entry: I = flying lead, otherwise a DIN plug. |
| 2F | 2 stations in one assembly, centralised exhaust. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
Both NO valves feed clamp cylinders whose springs do the gripping; energising a coil vents that line and releases the part for unloading, while the shared base keeps both clamp circuits on a single wiring run.
One normally open station holds the air knife running between cycles; the PLC energises the coil to cut the jet, and the second station serves a second nozzle from the same base supply.
The NO outlet keeps pilot pressure on a diaphragm valve through a control-power loss; energising the 3V2M vents the pilot so the process valve returns to its rest position.
Pick 3V2M when station density on one base matters more than per-valve flow: Cv 0.1 per valve, since air crosses the base. If one of the two stations needs more, fit an individual 3V2 (Cv 0.18 at 1/8 in, 0.19 at 1/4 in, vacuum-rated) or a 3V3 (Cv 0.62 at 1/4 in); 3V1 saves power at 3.0 W DC for light duty. Match five points before ordering: initial state NO (this code - NC cannot be converted later, no gasket flip or retrofit changes it), voltage AC220V, entry flying lead, 2 stations, centralised exhaust, plus PT thread as standard (G and NPT are order options). Double-acting cylinders need the AirTAC 4V series.
Confirm before you order
Two-station 3/2 normally open assembly on a 3V2M base with PT1/8 ports and centralised exhaust. Cv 0.1 per valve, operating pressure 0-0.8 MPa (0-114 psi), temperature -20 to 70 C, AC coil power 7 VA (DC versions 7.0 W), protection IP65 (DIN 40050). Air must be filtered to 40 um or finer; lubrication is not required. Each valve has a manual override.
NO is right when the outlet should pass air until the signal arrives - idle-blow circuits, fail-vent safety logic, or clamps that release on command. The state is fixed by the valve you order: the base gasket cannot be flipped and no wiring change converts NO to NC, so confirm the state before purchase.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.