The AirTAC Airtac 3V2M Solenoid Valve 3V2MNOCI-10F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
Ten NC 3/2 valves ride on one 3V2M base in the 3V2MNOCI-10F, each coil rated 7 VA at AC110V and finished with its own flying lead. The valves are direct-acting with spring return and a coaxial shut-off poppet, so every outlet stays vented until the corresponding coil energises.
Flying-lead entry suits machine builders who pull valve wiring back to a single marshalling panel: ten lead-outs, one shared air supply, one wiring route. Exhaust is centralised, merging all ten stations into one port so external piping stays short. Coil protection is IP65 (DIN 40050) and each valve carries a manual override. The NC state is fixed at order time - no field conversion is possible.
| Model | Airtac 3V2M Solenoid Valve 3V2MNOCI-10F |
|---|---|
| Series | 3V2M |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Initial state | Normally open |
| Item form | Complete assembly — 10 valves on a shared base |
| Exhaust | Centralised exhaust |
| Port size | 1/8 in |
| Thread | PT |
| Coil voltage | AC110V |
|---|---|
| Electrical entry | Flying lead (lead-out wire type) |
| Coil power | 7 VA |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Not rated for vacuum |
| Flow coefficient | Cv 0.1 |
| Temperature | -20 to 70 C |
| Construction | Coaxial shut-off (poppet), base-mounted, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V2M catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V2M | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| 1/8 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| NO | Normally open: air passes until the coil is energised. |
| AC110V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| I | Electrical entry: I = flying lead, otherwise a DIN plug. |
| 10F | 10 stations in one assembly, centralised exhaust. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
Ten spring-return diverters push parcels off a belt, each gate fired by its own NC valve from the shared base and supply.
A food line seals ten trays in one pass; each clamp cylinder vents automatically the moment its coil drops out.
Spring-return locators release in sequence on a machining indexer, held vented by design until each AC110V coil energises.
Check the power budget on a 10-station board: ten AC110V coils at 7 VA each mean about 70 VA if all pull in together, so size the control transformer for that worst case, not for a single valve. Flow is Cv 0.1 per station because the path runs through the base; step to individual 3V2 valves (Cv 0.18 at 1/8, 0.19 at 1/4, vacuum-rated) or 3V3 (Cv 0.62, 1/4) where a branch needs more. The 3.0 W DC 3V1 covers light-duty points.
Order by five matches: NC state (unchangeable after purchase), AC110V, flying lead, 10 stations, centralised exhaust. PT thread is the standard on this family, and G or NPT can be ordered to suit. Double-acting cylinders require the AirTAC 4V series instead.
Confirm before you order
Per station: Cv 0.1, operating pressure 0-0.8 MPa (0-114 psi), temperature -20 to 70 C, PT1/8 valve port. Coils: AC110V at 7 VA each, IP65 (DIN 40050). Construction: direct-acting 3/2 NC with spring return and a manual override on every valve.
Each port either feeds or vents a single load: single-acting spring-return cylinders, blow nozzles, clamps and pilot stages. It cannot drive a double-acting cylinder - that needs a 5-port valve, such as the AirTAC 4V series.