The AirTAC Airtac 3V2M Solenoid Valve 3V2MNOCI-18F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
The 3V2MNOCI-18F mounts eighteen 3/2 NC poppet valves on one manifold block with a single centralised exhaust. The coaxial shut-off design seals reliably, but because every flow path passes through the base, each station is Cv 0.1 - the honest price of packing eighteen valves into one PT1/8 gallery. Coils are AC220V at 7 VA with flying-lead entry for direct wiring.
All eighteen coils together draw about 126 VA when energised, worth checking against your transformer headroom. Shared supply and wiring also mean one manual override per valve is enough to jog any station during commissioning. NC holds every outlet vented until commanded, and the state is locked in at purchase - no conversion afterwards.
| Model | Airtac 3V2M Solenoid Valve 3V2MNOCI-18F |
|---|---|
| Series | 3V2M |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Initial state | Normally open |
| Item form | Complete assembly — 18 valves on a shared base |
| Exhaust | Centralised exhaust |
| Port size | 1/8 in |
| Thread | PT |
| Coil voltage | AC110V |
|---|---|
| Electrical entry | Flying lead (lead-out wire type) |
| Coil power | 7 VA |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Not rated for vacuum |
| Flow coefficient | Cv 0.1 |
| Temperature | -20 to 70 C |
| Construction | Coaxial shut-off (poppet), base-mounted, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V2M catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V2M | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| 1/8 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| NO | Normally open: air passes until the coil is energised. |
| AC110V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| I | Electrical entry: I = flying lead, otherwise a DIN plug. |
| 18F | 18 stations in one assembly, centralised exhaust. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
Eighteen clamp stations on a test bench close over castings during pressure decay checks, each venting automatically the instant its NC coil drops.
Sorting lanes use rows of small single-acting diverters; one manifold supplies and exhausts the whole row, keeping cabinet wiring to a single trunk.
Short-stroke impression cylinders on a press engage only while energised, which matches the fail-vented behaviour of these NC 3/2 stations.
Match five parameters to your project: initial state (NC), coil voltage, electrical entry, station count and exhaust routing, plus thread - PT standard, G or NPT on order. On sizing: 3V2M buys density at the cost of flow, so step a high-flow station to an individual 3V2 (Cv 0.18 at 1/8 in, 0.19 at 1/4 in, vacuum-rated) or 3V3 (Cv 0.62 at 1/4 in, vacuum-rated), or pick 3V1 at 3.0 W DC when power is tight. NC/NO is fixed at purchase and cannot be reversed later, and double-acting cylinders need the AirTAC 4V series.
Confirm before you order
Eighteen NC 3/2 stations, direct-acting, spring return, coaxial shut-off, centralised exhaust. Cv 0.1, pressure 0-0.8 MPa, temperature -20 to 70 C, AC220V coil power 7 VA per station (about 126 VA total energised), IP65 (DIN 40050), PT1/8 ports, PT thread standard, manual override fitted, air filtered to 40 um or finer without lubrication.
Each 3/2 valve feeds a single outlet or vents it, so it drives single-acting spring-return cylinders, on/off air blow, clamping and pilot duty. It will not drive a double-acting cylinder, which requires a 5-port valve such as the AirTAC 4V series. It also has no vacuum rating, so do not apply it to negative-pressure circuits.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.