The AirTAC Airtac 3V2M Solenoid Valve 3V2MNOE is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
The 3V2MNOE is a single 3/2 valve body in the normally open version: supply air passes straight through to the outlet at rest, and energising the AC24V coil shuts the path and vents downstream. The spring-return, direct-acting coaxial poppet switches without pilot air, so it operates across the full 0-0.8 MPa range.
It mounts on a 3V2M base so several valves can share one air feed and one wiring run, with Cv 0.1 per station and IP65 protection on the DIN socket connection. The AC24V coil draws 7 VA. Note that the NO state is ordered, not converted - the dedicated base gasket cannot be flipped to change NC into NO.
| Model | Airtac 3V2M Solenoid Valve 3V2MNOE |
|---|---|
| Series | 3V2M |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Initial state | Normally open |
| Port size | 1/8 in |
| Thread | PT |
| Coil voltage | AC24V |
|---|---|
| Electrical entry | DIN plug (DIN socket type) |
| Coil power | 7 VA |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Not rated for vacuum |
| Flow coefficient | Cv 0.1 |
| Temperature | -20 to 70 C |
| Construction | Coaxial shut-off (poppet), base-mounted, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V2M catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V2M | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| 1/8 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| NO | Normally open: air passes until the coil is energised. |
| AC24V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| — | Electrical entry: I = flying lead, otherwise a DIN plug. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
An analytical instrument keeps a sheath-air path open by default and closes it with the coil only during sample injection.
A packaging machine vents its clamping circuit to atmosphere on control power loss, letting springs retract the tooling.
A burner skid holds a small pilot-air stream continuously open and cuts it instantly when the AC24V signal drops.
Choose this body when a circuit must default to passing air - purge lines, vent paths, fail-open pilot duty - and your control voltage is AC24V. If the point is only lightly loaded, 3V1 saves power at 3.0 W DC; for higher flow per port use a standalone 3V2 (Cv 0.18 at 1/8, Cv 0.19 at 1/4) or 3V3 (Cv 0.62, 1/4), both vacuum-rated where this 3V2M body is not. NC and NO cannot be swapped after purchase, so order NO deliberately.
Match all five selection points: initial state, coil voltage (AC24V here), electrical entry (DIN plug), station count if building a manifold, exhaust choice, plus thread - PT standard, G or NPT to order. A double-acting cylinder requires the AirTAC 4V series.
Confirm before you order
Normally open 3/2 function, Cv 0.1 flow coefficient, 0-0.8 MPa operating pressure, -20 to 70 C temperature, AC24V coil at 7 VA, IP65 to DIN 40050, PT1/8 port with G or NPT as order options, manual override fitted, direct-acting spring return, coaxial shut-off construction.
Yes. Until the AC24V coil is energised, the valve feeds its outlet; energising it closes the path and vents downstream. This default-open state is built into the valve body - you cannot make an NC unit behave the same by reversing the base gasket, so order NO when a fail-open circuit is required. One 3/2 port drives one single-acting load; a double-acting cylinder needs a 5-port AirTAC 4V valve.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.