The AirTAC Airtac 3V2M Solenoid Valve 3V2MNOF-12F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
Twelve 3/2 normally open valves come pre-mounted on a 12-station 3V2M base in this assembly, PT threaded, exhausting through one common port. Air flows to each outlet whenever that station's coil is off; applying DC12V vents the circuit.
Stations combine and expand freely on the 3V2M platform, so a 12-station bank like this can grow later without repiping the supply. Each 12 V DIN-plug coil draws 7.0 W; all twelve energised is about 84 W, roughly 3.5 A at 12 V. The valves are IP65 (DIN 40050) and fitted with manual overrides. The normally open state cannot be changed after purchase - the dedicated base gasket is not reversible - so confirm NO before ordering.
| Model | Airtac 3V2M Solenoid Valve 3V2MNOF-12F |
|---|---|
| Series | 3V2M |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Initial state | Normally open |
| Item form | Complete assembly — 12 valves on a shared base |
| Exhaust | Centralised exhaust |
| Port size | 1/8 in |
| Thread | PT |
| Coil voltage | DC12V |
|---|---|
| Electrical entry | DIN plug (DIN socket type) |
| Coil power | 7.0 W |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Not rated for vacuum |
| Flow coefficient | Cv 0.1 |
| Temperature | -20 to 70 C |
| Construction | Coaxial shut-off (poppet), base-mounted, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V2M catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V2M | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| 1/8 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| NO | Normally open: air passes until the coil is energised. |
| DC12V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| — | Electrical entry: I = flying lead, otherwise a DIN plug. |
| 12F | 12 stations in one assembly, centralised exhaust. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
Twelve clamp cylinders on an engine-block machining fixture, one per critical bolt position, all controlled from a single 12 V supply and loom.
Twelve reagent draw-off points on a pilot-plant skid open at rest and shut on a 12 V command, with every station venting through the one shared exhaust route.
Twelve pneumatic interlock gates on an electronics burn-in rig switch from a single 12 V PLC rail, each gate holding its own station on the common manifold.
Order by five answers: normally open, DC12V, DIN plug, PT thread, and a 12-station centralised-exhaust base. If a station must vent on its own, the -D independent-exhaust variant is the alternative to order. There is no post-purchase state change: reversing the base gasket does not turn NC into NO or the reverse.
Size each circuit at Cv 0.1; where one outlet needs more, put a standalone 3V2 (Cv 0.18 at 1/8 in, 0.19 at 1/4 in) or a 3V3 (Cv 0.62, 1/4 in) there - both vacuum rated, unlike 3V2M. For minimum coil power, 3V1 needs just 3.0 W on DC. Any double-acting cylinder calls for a 5-port 4V valve instead.
Confirm before you order
Twelve stations, each Cv 0.1, 0-0.8 MPa (0-114 psi), -20 to 70 C, 7.0 W DC coil (7 VA on AC versions), IP65 to DIN 40050, PT1/8. All twelve energised is about 84 W, near 3.5 A at 12 V. Medium: air filtered to 40 um or finer, no lubrication required.
Choose NO (this code) when stations should pass air while power is off and vent only on command; choose NC when outlets must stay sealed until energised. The choice is final: 3V2M's dedicated base gasket cannot be reversed to convert the state, so decide before ordering. Either way, these 3/2 valves drive single-acting cylinders only - double-acting cylinders need the 5-port 4V series.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.