The AirTAC Airtac 3V2M Solenoid Valve 3V2MNOF-14F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.

  • Valve type3/2-way (3-port, 2-position)
  • Initial stateNormally open
  • Port size1/8 in
  • Coil voltageDC12V
  • Electrical entryDIN plug (DIN socket type)
  • Stations14
  • Flow (Cv)0.1
  • Series3V2M
$572.57 $590.46Save 3% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every 3V2M manifold set voltage, station and exhaust option on one page All 3V2M manifold set codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac 3V2M Solenoid Valve 3V2MNOF-14F

Fourteen single-solenoid 3/2 valves, all normally open, all DC12V, carried on one machined 3V2M base - that is the 3V2MNOF-14F in a sentence. Because the valves share one supply gallery and one wiring trunk, a fault shows up as a station-by-station pattern you can walk down with a meter, which is the quiet advantage of a manifold over fourteen separate valves and fourteen separate fitting runs.

Each valve is direct-acting with spring return and coaxial shut-off sealing, Cv 0.1, IP65 coil protection and a manual override for setup. Budget 98 W - about 8.2 A at 12 V - if all 14 coils pull in together, and plan one silencer for the centralised exhaust port. The initial state cannot be changed afterwards: the base gasket is dedicated and flipping it does not convert NO to NC.

Airtac 3V2M Solenoid Valve 3V2MNOF-14F Technical Specifications

ModelAirtac 3V2M Solenoid Valve 3V2MNOF-14F
Series3V2M
Valve type3/2-way (3-port, 2-position)
FunctionDirect-acting, single solenoid, spring return
Initial stateNormally open
Item formComplete assembly — 14 valves on a shared base
ExhaustCentralised exhaust
Port size1/8 in
ThreadPT
Coil voltageDC12V
Electrical entryDIN plug (DIN socket type)
Coil power7.0 W
Operating pressure0-0.8 MPa (0-114 psi)
Vacuum serviceNot rated for vacuum
Flow coefficientCv 0.1
Temperature-20 to 70 C
ConstructionCoaxial shut-off (poppet), base-mounted, spring return
ProtectionIP65 (DIN 40050)
MediumAir, filtered by a 40 µm or finer element. Lubrication not required.

Figures follow the official AirTAC 3V2M catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

The initial state cannot be changed after ordering. 3V2M uses a dedicated base gasket, and reversing or flipping that gasket does not convert NC to NO. Order the state you need up front.

Model Code: Airtac 3V2M Solenoid Valve 3V2MNOF-14F

3V2MBody — sets the flow, the coil power and whether vacuum is rated.
1/8 inPort size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in.
NONormally open: air passes until the coil is energised.
DC12VCoil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V.
—Electrical entry: I = flying lead, otherwise a DIN plug.
14F14 stations in one assembly, centralised exhaust.
PTPort thread. PT ships from stock; G and NPT are available to order.

What a 3/2 Valve Does

A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.

That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.

It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.

Where the Airtac 3V2M Solenoid Valve 3V2MNOF-14F Is Used

conveyor_belt

Bottling line diverters

Fourteen pusher cylinders divert bottles between lanes on a filling line; normally open logic keeps air on the pushers until each DC12V coil is energised to vent its station.

bolt

Drill fixture clamps

A CNC drilling fixture clamps workpieces with swing clamps fed from one shared supply gallery, so a dropped hose or tripped supply is visible across all 14 stations at once.

settings_input_component

Control cabinet test bench

A wiring test bench uses the 14-station manifold to sequence air cylinders that probe connector blocks; DIN plug coils unplug individually during rework without disturbing neighbours.

Is the Airtac 3V2M Solenoid Valve 3V2MNOF-14F the Right Part?

Start from the load, not the manifold. A 3/2 valve feeds or vents one outlet, so it drives single-acting spring-return cylinders, blow nozzles and pilot stages; double-acting cylinders need a 5-port valve from the AirTAC 4V series. Where a station needs more than Cv 0.1, place an individual 3V2 (Cv 0.18 at 1/8 in, 0.19 at 1/4 in, vacuum-rated) or a 3V3 (Cv 0.62, 1/4 in) next to the assembly; 3V1 at 3.0 W DC covers low-power points. Then lock the order code: normally open state (fixed for life), DC12V coil, DIN plug entry, 14 stations, centralised exhaust, PT thread with G or NPT as order options.

Confirm before you order

  • ✓ Port size and thread (PT from stock; G / NPT to order)
  • ✓ Initial state — NC or NO, ordered up front
  • ✓ Coil voltage matches your controller output
  • ✓ Electrical entry — DIN plug or flying lead
  • ✓ Single valve, bare base, or complete assembly
  • ✓ Single-acting duty, not double-acting
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Stay within 0-0.8 MPa (0-114 psi) operating pressure.
  • check Match the coil voltage to your controller output.
  • check Use the manual override to test before powering up.
  • check Leave the exhaust port clear, or fit a silencer.
  • check Blank any unused station on the base before pressurising.
  • check Wiring by qualified personnel, per AirTAC documentation.

Airtac 3V2M Solenoid Valve 3V2MNOF-14F FAQ

Fourteen normally open 3/2 valves on one base: Cv 0.1 per valve, 0-0.8 MPa (0-114 psi) operating pressure, -20 to 70 C temperature range, 7.0 W per DC12V coil (AC versions are 7 VA), IP65 (DIN 40050), PT1/8 ports and centralised exhaust.

No. Each of the 14 valves has three ports - supply, outlet and exhaust - and two states, so it feeds or vents one outlet. That suits single-acting spring-return cylinders, clamps, blow duty and pilot lines. A double-acting cylinder needs two outlet ports, which means a 5-port valve from the AirTAC 4V series.

verified

Authorized Export Seller

Genuine AirTAC parts produced by the AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac 3V2M Solenoid Valve 3V2MNOF-14F

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 3V2MNOF-14F and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.