The AirTAC Airtac 3V2M Solenoid Valve 3V2MNOF-16F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
The 3V2MNOF-16F is a complete 16-station manifold assembly built around AirTAC 3V2M normally open (NO) poppet valves running on DC12V coils. Each 3/2 valve is direct-acting with spring return and a coaxial shut-off element, so it either feeds the outlet or vents it. Being normally open, every station passes air while de-energised and shuts off only when its 7.0 W coil is energised - useful wherever the safe condition is air flowing, not blocked.
All sixteen valve bodies sit on one dedicated base, so the assembly draws one shared air supply and one shared wiring loom instead of sixteen separate connections. Manual overrides are fitted to each body for commissioning, and every valve carries an IP65 (DIN 40050) coil rating. Worth budgeting up front: with all sixteen DC12V coils energised the assembly draws about 112 W, roughly 9.3 A at 12 V - size the 12 V supply for that worst case, not for one station.
| Model | Airtac 3V2M Solenoid Valve 3V2MNOF-16F |
|---|---|
| Series | 3V2M |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Initial state | Normally open |
| Item form | Complete assembly — 16 valves on a shared base |
| Exhaust | Centralised exhaust |
| Port size | 1/8 in |
| Thread | PT |
| Coil voltage | DC12V |
|---|---|
| Electrical entry | DIN plug (DIN socket type) |
| Coil power | 7.0 W |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Not rated for vacuum |
| Flow coefficient | Cv 0.1 |
| Temperature | -20 to 70 C |
| Construction | Coaxial shut-off (poppet), base-mounted, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V2M catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V2M | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| 1/8 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| NO | Normally open: air passes until the coil is energised. |
| DC12V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| — | Electrical entry: I = flying lead, otherwise a DIN plug. |
| 16F | 16 stations in one assembly, centralised exhaust. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
Because each NO valve opens its supply path while de-energised, a mains loss leaves single-acting guard clamps fed rather than stranded; energising the DC12V coil vents the clamp so the spring retracts it on command.
On a 16-position saw line the blow-off nozzles need air by default; each normally open 3/2 station delivers it continuously and only cuts a jet when the controller energises that station's coil.
One shared supply and one shared wiring loom feed all 16 pilot-duty stations through the common base, so a technician can isolate a faulty station on the block instead of tracing sixteen separate valve installs.
Choose this assembly when you need high valve density in one block and your circuit wants air to flow at rest. The flow path runs through the base, so each station is Cv 0.1; if any station must pass more air, mount an individual 3V2 instead (Cv 0.18 at 1/8 in, 0.19 at 1/4 in, vacuum-rated) or a 3V3 (Cv 0.62, 1/4 in, vacuum-rated). For low-duty points where coil heat matters more than flow, the 3V1 at 3.0 W DC is the lighter option. If you actually need to drive a double-acting cylinder, that takes a 5-port AirTAC 4V valve, not a 3/2.
Match five points before ordering: initial state (NO here), coil voltage (DC12V), electrical entry (DIN plug on this code; a flying-lead I version exists), station count (16) and exhaust type (centralised on this code; independent D versions exist). Thread is PT as standard, with G and NPT available to order. Critically, the NO state is fixed at order time - the dedicated base gasket cannot be flipped to convert NO to NC, so a normally closed circuit needs a different SKU.
Confirm before you order
Each of the 16 stations is a 3/2 direct-acting, spring-return, normally open valve with Cv 0.1, operating pressure 0-0.8 MPa (0-114 psi), temperature range -20 to 70 C, and a DC12V coil rated 7.0 W (16 coils together draw about 112 W, near 9.3 A at 12 V). Coil protection is IP65 (DIN 40050), air must be filtered to 40 um or finer with no lubrication required, ports are PT1/8 with a centralised exhaust, and a manual override is fitted per valve.
No. The NO initial state is fixed when ordered - the 3V2M uses a dedicated base gasket and reversing or flipping that gasket does not convert the state, so a normally closed circuit must be ordered as a different SKU. Function-wise each 3/2 station has three ports and two states, feeding or venting the outlet, so it suits single-acting spring-return cylinders, blow-off, clamping and pilot duty - but it cannot drive a double-acting cylinder, which needs a 5-port AirTAC 4V valve.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.