The AirTAC Airtac 3V2M Solenoid Valve 3V2MNOF-18F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
Eighteen normally-open 3/2 valves share one 3V2M base and one wiring run in this assembly. Every station passes air at rest; energising its 7.0 W DC12V coil closes that station's coaxial poppet and dumps the downstream line to the centralised exhaust. The direct-acting construction means no minimum pressure is needed to shift the valve - the solenoid and spring do all the work.
Size the power supply for the worst case: eighteen coils at 7.0 W is 126 W, roughly 10.5 A at 12 V if the whole bank sits energised. With one shared supply port, PT1/8 threading, IP65 DIN plug connections and a manual override on each valve, the 18-station layout suits control panels where wiring channels are scarce.
| Model | Airtac 3V2M Solenoid Valve 3V2MNOF-18F |
|---|---|
| Series | 3V2M |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Initial state | Normally open |
| Item form | Complete assembly — 18 valves on a shared base |
| Exhaust | Centralised exhaust |
| Port size | 1/8 in |
| Thread | PT |
| Coil voltage | DC12V |
|---|---|
| Electrical entry | DIN plug (DIN socket type) |
| Coil power | 7.0 W |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Not rated for vacuum |
| Flow coefficient | Cv 0.1 |
| Temperature | -20 to 70 C |
| Construction | Coaxial shut-off (poppet), base-mounted, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V2M catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V2M | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| 1/8 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| NO | Normally open: air passes until the coil is energised. |
| DC12V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| — | Electrical entry: I = flying lead, otherwise a DIN plug. |
| 18F | 18 stations in one assembly, centralised exhaust. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
Normally-open valves hold each single-acting clamp fed from a shared supply; energising the coil vents and releases that spindle, so a control fault drops all clamps open.
Eighteen diverters on one manifold: air passes to each diverter cylinder at rest, and the PLC energises a station to stop and vent it - one supply, one wiring route.
A 3/2 normally-open valve per sample line keeps carrier air flowing by default; each DC12V coil shuts one stream for calibration without starving the other seventeen.
Use 3V2M where manifold density beats raw flow: Cv 0.1 per valve is the price of routing the flow through the base. A station that needs more air should take an individual 3V2 (Cv 0.18 at 1/8 in, Cv 0.19 at 1/4 in, vacuum-rated), and the highest-flow 3V option is 3V3 (Cv 0.62, 1/4 in, vacuum-rated); 3V1 at 3.0 W DC is the low-power alternative for small duties. Double-acting cylinders are out of scope for any 3-port valve - specify AirTAC 4V there. Confirm these five choices before ordering: NO state (fixed at purchase, not field-convertible), DC12V, DIN plug, 18 stations, centralised exhaust, and thread - PT is standard, G and NPT are order options.
Confirm before you order
Every DC12V coil is rated 7.0 W, so a fully energised 18-station bank draws about 126 W, near 10.5 A at 12 V. Choose a 12 V supply with headroom above that. Flow per valve is Cv 0.1, pressure 0-0.8 MPa (0-114 psi), temperature -20 to 70 C, protection IP65 (DIN 40050).
Each 3/2 station feeds or vents one line, so it drives single-acting spring-return cylinders, air blow, clamping and pilot stages. It cannot drive a double-acting cylinder - that requires a 5-port valve from the AirTAC 4V series. Note also that NO cannot be changed to NC after purchase.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.