The AirTAC Airtac 3V2M Solenoid Valve 3V2MNOF-4F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
Four normally open 3/2 valve bodies on one manifold give the 3V2MNOF-4F four switchable air outputs fed from a single supply through a single wiring entry. Every body is direct-acting and spring-returned with a coaxial poppet for positive shut-off, passing Cv 0.1 through PT1/8 ports. De-energised, each outlet passes air; firing its DC12V coil closes that station.
The base format leaves room to grow: 3V2M stations combine and expand freely, and valves of different types can be mixed on compatible bases as the machine evolves. Four DC coils at 7.0 W add up to 28 W, about 2.3 A at 12 V with all stations energised - a figure to give your power-supply sizing. Remember the NO state is fixed at order time and cannot be converted in the field.
| Model | Airtac 3V2M Solenoid Valve 3V2MNOF-4F |
|---|---|
| Series | 3V2M |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Initial state | Normally open |
| Item form | Complete assembly — 4 valves on a shared base |
| Exhaust | Centralised exhaust |
| Port size | 1/8 in |
| Thread | PT |
| Coil voltage | DC12V |
|---|---|
| Electrical entry | DIN plug (DIN socket type) |
| Coil power | 7.0 W |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Not rated for vacuum |
| Flow coefficient | Cv 0.1 |
| Temperature | -20 to 70 C |
| Construction | Coaxial shut-off (poppet), base-mounted, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V2M catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V2M | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| 1/8 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| NO | Normally open: air passes until the coil is energised. |
| DC12V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| — | Electrical entry: I = flying lead, otherwise a DIN plug. |
| 4F | 4 stations in one assembly, centralised exhaust. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
An OEM control panel with four 12 V pneumatic outputs tied to PLC points, each NO station proved flowing at rest before cycle start.
A pick-and-place end-effector carrying four small single-acting fingers, each released by its own valve on a shared 12 V manifold behind the wrist.
A counting unit where four per-lane ejector pulses stay charged until each coil fires, letting the PLC trim output one lane at a time.
Pick this code when a cell needs four ON/OFF air duties served from one point. Cv 0.1 per station is the trade-off for manifold density: step up to an individual 3V2 (Cv 0.18 at 1/8 inch, 0.19 at 1/4 inch, vacuum-rated) or 3V3 (Cv 0.62, 1/4 inch, vacuum-rated) where a function needs more flow, or use 3V1 at 3.0 W DC for light, low-power duties. Double-acting cylinders require a 5-port valve - go to the AirTAC 4V series.
Before ordering, settle five points: normally open state, DC12V coil, DIN plug entry, 4 stations, centralised exhaust, and the thread (PT standard, with G and NPT as catalogue options). NC and NO cannot be swapped after purchase.
Confirm before you order
Four normally open 3/2 stations: Cv 0.1 flow coefficient, 0-0.8 MPa pressure range, -20 to 70 C, DC12V coils at 7.0 W each (28 W with all four on), IP65 (DIN 40050), PT1/8 ports, manual override per body.
Each is a 3/2 valve with one outlet, so it feeds or vents single-acting spring-return cylinders, swing clamps, air blow nozzles and pilot stages. It cannot drive a double-acting cylinder - that needs a 5-port valve such as the AirTAC 4V series.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.