The AirTAC Airtac 3V2M Solenoid Valve 3V2MNOF-9F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
The 3V2MNOF-9F is a complete nine-station bank of normally open 3/2 solenoid valves mounted on one shared 3V2M base. Every valve is direct-acting with a spring return and a coaxial poppet seat, so the whole bank runs from a single PT1/8 air supply and a single wiring run - when a station misbehaves, you trace one supply and one circuit instead of chasing nine separate valves.
Because the valves are normally open, each outlet passes air until its DC12V coil is energised, which suits fail-pressurised duties such as purge headers and default-release clamps. Each coil draws 7.0 W, so nine stations energised together pull 63 W, about 5.3 A at 12 V. Coils are rated IP65, flow is Cv 0.1 per station, a manual override sits on every valve for commissioning, and the NO state is factory-fixed: no gasket flip or field change can turn this bank into an NC one.
| Model | Airtac 3V2M Solenoid Valve 3V2MNOF-9F |
|---|---|
| Series | 3V2M |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Initial state | Normally open |
| Item form | Complete assembly — 9 valves on a shared base |
| Exhaust | Centralised exhaust |
| Port size | 1/8 in |
| Thread | PT |
| Coil voltage | DC12V |
|---|---|
| Electrical entry | DIN plug (DIN socket type) |
| Coil power | 7.0 W |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Not rated for vacuum |
| Flow coefficient | Cv 0.1 |
| Temperature | -20 to 70 C |
| Construction | Coaxial shut-off (poppet), base-mounted, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V2M catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V2M | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| 1/8 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| NO | Normally open: air passes until the coil is energised. |
| DC12V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| — | Electrical entry: I = flying lead, otherwise a DIN plug. |
| 9F | 9 stations in one assembly, centralised exhaust. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
Nine spring-return lock cylinders along a reefer trailer sidewall stay released through the normally open valves and lock on coil signal, all powered from the truck's 12 V battery without an inverter.
A nine-nozzle air rinse on a beverage line blows by default and stops each nozzle individually when its coil energises - a duty the NO state handles without extra logic.
An HVAC lab cycles nine damper actuators from one 12 V supply; each 3/2 station feeds or vents its spring-return cylinder while the shared base keeps wiring down to two runs.
Treat 3V2M as the density choice: Cv 0.1 per station is the price of routing everything through one base. If a single station needs more flow, hang an individual 3V2 valve there instead (Cv 0.18 at 1/8 in, Cv 0.19 at 1/4 in, and vacuum-rated); step up to 3V3 (Cv 0.62, 1/4 in, also vacuum-rated) for the highest flow in the 3V range, or use 3V1 where a 3.0 W DC draw matters more than flow.
Before ordering, fix five points: normally open state (which cannot be changed after purchase - flipping the dedicated base gasket does not convert it), DC12V coil, DIN plug entry, nine stations with centralised exhaust, and PT1/8 threads (G and NPT are catalogue options to order). If the machine includes a double-acting cylinder, that needs the 5-port AirTAC 4V series, not any 3/2 model.
Confirm before you order
Each of the nine valves is a 3/2 direct-acting poppet with spring return: Cv 0.1, operating pressure 0-0.8 MPa (0-114 psi), media temperature -20 to 70 C, IP65 (DIN 40050) coils drawing 7.0 W on DC12V, PT1/8 ports and a manual override. Air must be filtered to 40 um or finer; lubrication is not required.
No. 3V2M uses a dedicated base gasket, and the catalogue states plainly that reversing or flipping that gasket does not change the initial state. The state is set at the factory, so order NO or NC correctly up front. Check the exact coil voltage and entry type against your panel before ordering.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.